Paper
14 July 1988 Development Of An Extended Blackbody Source For The Calibration Of Infrared Systems (II)
Gao Kuiming, Zhang Wei, Xie Zhi, Shang Guanghui
Author Affiliations +
Abstract
An extended blackbody source with cavity effect realized bx gravity heat pipe is reported in this paper, which has an operating temperature range of 40°C to 150°C. The diameter of its working area is 150 mm. THERMO TRACER 6T61 is used to measure the temperature distribution over the working area. The results show that the maximum temperature difference within ninety eight percent of the working area is less than 1.4°C. The integrated emissivity of the extended blackbody source to a concentric circular detector is 0.996. This extended source has advantages of relatively good temperature uniformity, simple construction, and low cost.
© (1988) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Gao Kuiming, Zhang Wei, Xie Zhi, and Shang Guanghui "Development Of An Extended Blackbody Source For The Calibration Of Infrared Systems (II)", Proc. SPIE 0940, Infrared Scene Simulation: Systems, Requirements, Calibration, Devices, and Modeling, (14 July 1988); https://doi.org/10.1117/12.947147
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Temperature metrology

Black bodies

Calibration

Infrared radiation

Infrared imaging

Instrument modeling

Scene simulation

Back to Top