We have developed and are deploying the Vast Area Detection for Experimental Radiochemistry (VADER) diagnostic to collect shot debris and interact with post-shot reaction products at the NIF. VADER uses quick release collectors that are easily reconfigured for different materials and geometries. Collectors are located ~50 cm from the NIF target; each of up to 9 collectors views ~0.005-0.0125 steradians solid angle, dependent upon configuration. Dynamic loading of the NIF target vaporized mass was modelled using LS-DYNA. 3-dimensional printing was utilized to expedite the design process. Model-based manufacturing was used throughout. We will describe the design and operation of this diagnostic as well as some initial results. |