Paper
24 August 2015 CdTe focal plane detector for hard x-ray focusing optics
Paul Seller, Matthew D. Wilson, Matthew C. Veale, Andreas Schneider, Jessica Gaskin, Colleen Wilson-Hodge, Steven Christe, Albert Y. Shih, Kyle Gregory, Andrew Inglis, Marco Panessa
Author Affiliations +
Abstract
The demand for higher resolution x-ray optics (a few arcseconds or better) in the areas of astrophysics and solar science has, in turn, driven the development of complementary detectors. These detectors should have fine pixels, necessary to appropriately oversample the optics at a given focal length, and an energy response also matched to that of the optics. Rutherford Appleton Laboratory have developed a 3-side buttable, 20 mm x 20 mm CdTe-based detector with 250 μm square pixels (80x80 pixels) which achieves 1 keV FWHM @ 60 keV and gives full spectroscopy between 5 keV and 200 keV. An added advantage of these detectors is that they have a full-frame readout rate of 10 kHz. Working with NASA Goddard Space Flight Center and Marshall Space Flight Center, 4 of these 1mm-thick CdTe detectors are tiled into a 2x2 array for use at the focal plane of a balloon-borne hard-x-ray telescope, and a similar configuration could be suitable for astrophysics and solar space-based missions. This effort encompasses the fabrication and testing of flightsuitable front-end electronics and calibration of the assembled detector arrays. We explain the operation of the pixelated ASIC readout and measurements, front-end electronics development, preliminary X-ray imaging and spectral performance, and plans for full calibration of the detector assemblies. Work done in conjunction with the NASA Centers is funded through the NASA Science Mission Directorate Astrophysics Research and Analysis Program.
© (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Paul Seller, Matthew D. Wilson, Matthew C. Veale, Andreas Schneider, Jessica Gaskin, Colleen Wilson-Hodge, Steven Christe, Albert Y. Shih, Kyle Gregory, Andrew Inglis, and Marco Panessa "CdTe focal plane detector for hard x-ray focusing optics", Proc. SPIE 9601, UV, X-Ray, and Gamma-Ray Space Instrumentation for Astronomy XIX, 960103 (24 August 2015); https://doi.org/10.1117/12.2191617
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Spatial resolution

X-ray optics

X-rays

Astrophysics

Space telescopes

Spectroscopy

RELATED CONTENT

Status of ART-XC / SRG instrument
Proceedings of SPIE (September 04 2015)
Advanced X-Ray Astrophysics Facility (AXAF)
Proceedings of SPIE (August 15 1980)
Spectrum-RG/eROSITA/Lobster astrophysical mission
Proceedings of SPIE (June 13 2006)
Generation X mission and technology studies for an x...
Proceedings of SPIE (October 11 2004)

Back to Top