You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
7 August 2015New float equivalent calibration method for 2D image measuring system
Pixel equivalent is an important parameter to describe the relationship between pixels of digital images and actual size of measured piece in a 2D image measuring system. It is mainly calibrated with the standard component method, which is traditionally off-line and requires measuring conditions and attitude of devices to remain constant while measuring and calibrating. To overcome above limitations, a new calibration method is proposed in this paper which is defined as the float equivalent method. This method requires the standard component and measured piece be placed in image measuring system simultaneously. Everytime before measuring, no matter aiming at the same measuring point or not, the pixel equivalent is calibrated for this specific time, specific condition, specific measuring point, and specific object distance. This method has the advantage of reducing the influence of conditions changing on the accuracy without additional calibration equipment or operations. The steel tape verification system is taken as an example to testify the effectiveness of the method.
Jiansong Gou,Zhong Wang,Ruijun Lu, andXinlan Shen
"New float equivalent calibration method for 2D image measuring system", Proc. SPIE 9623, 2015 International Conference on Optical Instruments and Technology: Optoelectronic Measurement Technology and Systems, 962310 (7 August 2015); https://doi.org/10.1117/12.2192835
The alert did not successfully save. Please try again later.
Jiansong Gou, Zhong Wang, Ruijun Lu, Xinlan Shen, "New float equivalent calibration method for 2D image measuring system," Proc. SPIE 9623, 2015 International Conference on Optical Instruments and Technology: Optoelectronic Measurement Technology and Systems, 962310 (7 August 2015); https://doi.org/10.1117/12.2192835