1 July 2015 Multi-point hydrogen detection system using hetero-core structured optical fiber hydrogen tip sensor based on surface plasmon resonance and pseudorandom noise code correlation reflectometry
Author Affiliations +
Proceedings Volume 9655, Fifth Asia-Pacific Optical Sensors Conference; 965515 (2015) https://doi.org/10.1117/12.2184381
Event: Fifth Asia Pacific Optical Sensors Conference, 2015, Jeju, Korea, Republic of
Abstract
In this paper, the multi-point hydrogen detection system using the hetero-core optical fiber hydrogen tip sensor based on surface plasmon resonance (SPR) and Pseudorandom Noise code correlation reflectometry (PNCR) has been proposed. This method makes use of the correlation between a launched pseudorandom noise code signal and its reflection, can obtain a high signal to noise ration. We demonstrated the 4 sensors characteristics to 4% hydrogen. It was observed from experimental results that all sensors induced a response time of 15 s for 4% hydrogen for the 25-nm Au / 60-nm Ta2O5 / 5-nm Pd multi-layers film. In addition, all sensors were detected the hydrogen concentration with sufficient sensitivities.
© (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ai Hosoki, Ai Hosoki, Michiko Nishiyama, Michiko Nishiyama, Hirotaka Igawa, Hirotaka Igawa, Atsushi Seki, Atsushi Seki, Kazuhiro Watanabe, Kazuhiro Watanabe, } "Multi-point hydrogen detection system using hetero-core structured optical fiber hydrogen tip sensor based on surface plasmon resonance and pseudorandom noise code correlation reflectometry", Proc. SPIE 9655, Fifth Asia-Pacific Optical Sensors Conference, 965515 (1 July 2015); doi: 10.1117/12.2184381; https://doi.org/10.1117/12.2184381
PROCEEDINGS
4 PAGES


SHARE
Back to Top