You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
27 September 2016A cylinder based calibration method for integrating a line structured light sensor with a rotation-translation platform
As a non-contact measuring apparatus, line structured light sensor (LSLS) can only get one profile of an object without the combination with other motional axes. To achieve the complete 3D measurement, a rotation-translation platform was integrated with the LSLS, and a cylinder based calibration method was also brought out. Firstly, the calibration model was proposed to determine the transformation matrix between the measuring coordinate frame (MCF) and the sensor coordinate frame (SCF). This model relies on the fact that the projection of an arbitrary intersection profile between the laser plane and the cylinder in its axis direction lies on a circle with a radius equal to the cylinder. Then, for a specified rotated angle and translated position of the object, the measured data from the SCF could all be transformed into the MCF, and the complete surface data could be obtained. Finally, a cylinder and a rectangular block were inspected by the proposed method. The surface data was successfully obtained and their intersection profiles indicate a high measuring accuracy of the proposed method. The method was further verified by the measured results of a screw surface.
Jingbo Zhou,Yuehua Li, andLijian Liu
"A cylinder based calibration method for integrating a line structured light sensor with a rotation-translation platform", Proc. SPIE 9684, 8th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test, Measurement Technology, and Equipment, 96841Q (27 September 2016); https://doi.org/10.1117/12.2242943
The alert did not successfully save. Please try again later.
Jingbo Zhou, Yuehua Li, Lijian Liu, "A cylinder based calibration method for integrating a line structured light sensor with a rotation-translation platform," Proc. SPIE 9684, 8th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test, Measurement Technology, and Equipment, 96841Q (27 September 2016); https://doi.org/10.1117/12.2242943