26 January 2016 Simulation of x-ray transmitted in the square polycapillary x-ray lens
Author Affiliations +
Proceedings Volume 9796, Selected Papers of the Photoelectronic Technology Committee Conferences held November 2015; 97961U (2016) https://doi.org/10.1117/12.2229385
Event: Selected Proceedings of the Chinese Society for Optical Engineering Conferences held November 2015, 2015, Various, China
Abstract
To study the transmission property of the square polycapillary x-ray lens and verify its feasibility using in the x-ray pulsar navigation a geometrical description of it and the basic theory of the transmission of x-rays are presented. A method of numerical calculation is developed based on ray-tracing theory. The method simulates the intensity distribution and calculates the transmission efficiency of x-rays propagating through a square polycapillary lens. The transmission rule of the x-ray propagation in the x-ray lens can be got, after tracing a large number of x-ray beams. A program based on ray-tracing method was designed to simulate the transmission efficiency of an x-ray lens and the light spot gained from it. The transmission property of the square polycapillary x-ray lens is studied based on this program. And the study shows that the transmission property of the square polycapillary x-ray lens is good, and it has the potential of being used in the area of x-ray pulsar navigation.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Shiqi Peng, Shiqi Peng, Zhiguo Liu, Zhiguo Liu, Tianxi Sun, Tianxi Sun, Kai Wang, Kai Wang, Longtao Yi, Longtao Yi, Kui Yang, Kui Yang, Man Chen, Man Chen, Jinbang Wang, Jinbang Wang, } "Simulation of x-ray transmitted in the square polycapillary x-ray lens", Proc. SPIE 9796, Selected Papers of the Photoelectronic Technology Committee Conferences held November 2015, 97961U (26 January 2016); doi: 10.1117/12.2229385; https://doi.org/10.1117/12.2229385
PROCEEDINGS
8 PAGES


SHARE
RELATED CONTENT

Monocrystal diffractometer: a comparator
Proceedings of SPIE (July 29 2002)
Method of investigating polycapillary performance
Proceedings of SPIE (July 06 1997)
Nontraditional grazing incidence optics for x-ray astronomy
Proceedings of SPIE (February 02 1993)
X-ray capillary system for hard x-ray astronomy
Proceedings of SPIE (November 18 1998)
Synchrotron radiation focusing by polycapillary lens
Proceedings of SPIE (December 05 2006)

Back to Top