17 May 2016 Experimental investigations and applications of cryogenic heat pipes
Author Affiliations +
Abstract
In the infrared system, in order to decrease the background radiation and maximize the sensitivity, cooling down the aft-optic components' temperature is a better choice. Some two-phase devices such as grooved heat pipe or loop heat pipe (LHP) were used to link the cold sink and IR aft-optic components. This paper presented the testing results of cryogenic grooved heat pipes which were used in some infrared test systems in the temperature range of 160~210K with different heat load conditions. Also, some experimental results of cryogenic loop heat pipe were introduced in this paper.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Enguang Liu, Fan Yang, YongBin Mu, Yinong Wu, "Experimental investigations and applications of cryogenic heat pipes", Proc. SPIE 9821, Tri-Technology Device Refrigeration (TTDR), 98210T (17 May 2016); doi: 10.1117/12.2223853; https://doi.org/10.1117/12.2223853
PROCEEDINGS
10 PAGES


SHARE
Back to Top