Translator Disclaimer
Paper
2 May 2016 LED characterization for development of on-board calibration unit of CCD-based advanced wide-field sensor camera of Resourcesat-2A
Author Affiliations +
Abstract
The Advanced Wide Field Sensor (AWiFS) camera caters to high temporal resolution requirement of Resourcesat-2A mission with repeativity of 5 days. The AWiFS camera consists of four spectral bands, three in the visible and near IR and one in the short wave infrared. The imaging concept in VNIR bands is based on push broom scanning that uses linear array silicon charge coupled device (CCD) based Focal Plane Array (FPA). On-Board Calibration unit for these CCD based FPAs is used to monitor any degradation in FPA during entire mission life. Four LEDs are operated in constant current mode and 16 different light intensity levels are generated by electronically changing exposure of CCD throughout the calibration cycle. This paper describes experimental setup and characterization results of various flight model visible LEDs (λP=650nm) for development of On-Board Calibration unit of Advanced Wide Field Sensor (AWiFS) camera of RESOURCESAT-2A. Various LED configurations have been studied to meet dynamic range coverage of 6000 pixels silicon CCD based focal plane array from 20% to 60% of saturation during night pass of the satellite to identify degradation of detector elements. The paper also explains comparison of simulation and experimental results of CCD output profile at different LED combinations in constant current mode.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Abhijit Chatterjee and Anurag Verma "LED characterization for development of on-board calibration unit of CCD-based advanced wide-field sensor camera of Resourcesat-2A", Proc. SPIE 9881, Earth Observing Missions and Sensors: Development, Implementation, and Characterization IV, 98811W (2 May 2016); https://doi.org/10.1117/12.2223554
PROCEEDINGS
4 PAGES


SHARE
Advertisement
Advertisement
RELATED CONTENT

Flat-field calibration of CCD detector for long trace profiler
Proceedings of SPIE (September 20 2007)
CUBIC: preflight calibration status
Proceedings of SPIE (September 01 1995)
Quantum efficiency of the XMM pn-CCD camera
Proceedings of SPIE (October 22 1999)

Back to Top