We present an alternative Corrector-ADC design for GMT. The design consists of just 3 silica lenses, of maximum size 1.51m, and includes only a single low-precision asphere for 20' field-of-view, and none for 10'. The polychromatic (360nm-1300nm) image quality is d80<0.043" at zenith and d80<0.20" for ZD<60 degrees. The monochromatic image quality is d80<0.1" everywhere, and typically ~0.05". The ADC action is achieved by tilt and translation of all three lenses; L1 and L2 via simple slide mechanisms each using a single encoded actuator, and L3 via a novel ‘tracker-ball’ support and three actuators. There is also a small motion of M2 via the hexapod, automatically generated by the AGWS system. The ADC action causes a small non-telecentricity, but this is much less than the unavoidable chromatic effects shared with the baseline design. The ADC action also changes the distortion pattern of the telescope, but this can be used positively, to reduce the maximum image motion due to differential refraction by a factor of three. The transmission is superb at all wavelengths, because of the reduced number of air/glass surfaces, and the use only of fused silica.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Will Saunders, Peter Gillingham, Sean Lin, Bob Woodruff, and Andrew Rakich "An all-silica three element wide-field corrector for GMT", Proc. SPIE 9906, Ground-based and Airborne Telescopes VI, 99063H (8 August 2016); https://doi.org/10.1117/12.2234468
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Silica

Vignetting

Lenses

Telescopes

Image quality

Aspheric lenses

Distortion

RELATED CONTENT

Tolerances in panoramic lenses
Proceedings of SPIE (September 08 2014)
Optical design of the WIYN One Degree Imager (ODI)
Proceedings of SPIE (December 24 2002)
A Compact f 2 To f 5 Converter And Field...
Proceedings of SPIE (November 03 1983)
Status of the design and fabrication of the GTC mirrors
Proceedings of SPIE (July 20 2000)

Back to Top