Techniques are described for tolerancing a radial velocity spectrometer system within Zemax, including: how to set up and verify the tolerancing model, performance metrics and tolerance operands used, as well as post- Zemax analysis methods. Use of the tolerancing model for various analyses will be discussed, such as: alignment sensitivity, radial velocity sensitivity, and sensitivity of the optical system to temperature changes. Tolerance results from the Keck Planet Finder project (a precision radial velocity spectrometer of asymmetric white pupil design) will be shown.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Steven R. Gibson, Steven R. Gibson, } "Tolerancing a radial velocity spectrometer within Zemax", Proc. SPIE 9911, Modeling, Systems Engineering, and Project Management for Astronomy VI, 99112C (19 August 2016); doi: 10.1117/12.2233059; https://doi.org/10.1117/12.2233059