22 July 2016 Back-illuminate fiber system research for multi-object fiber spectroscopic telescope
Author Affiliations +
Abstract
In the telescope observation, the position of fiber will highly influence the spectra efficient input in the fiber to the spectrograph. When the fibers were back illuminated on the spectra end, they would export light on the positioner end, so the CCD cameras could capture the photo of fiber tip position covered the focal plane, calculates the precise position information by light centroid method and feeds back to control system. A set of fiber back illuminated system was developed which combined to the low revolution spectro instruments in LAMOST. It could provide uniform light output to the fibers, meet the requirements for the CCD camera measurement. The paper was introduced the back illuminated system design and different test for the light resource. After optimization, the effect illuminated system could compare with the integrating sphere, meet the conditions of fiber position measurement.Using parallel controlled fiber positioner as the spectroscopic receiver is an efficiency observation system for spectra survey, has been used in LAMOST recently, and will be proposed in CFHT and rebuilt telescope Mayall. In the telescope observation, the position of fiber will highly influence the spectra efficient input in the fiber to the spectrograph. When the fibers were back illuminated on the spectra end, they would export light on the positioner end, so the CCD cameras could capture the photo of fiber tip position covered the focal plane, calculates the precise position information by light centroid method and feeds back to control system. After many years on these research, the back illuminated fiber measurement was the best method to acquire the precision position of fibers. In LAMOST, a set of fiber back illuminated system was developed which combined to the low revolution spectro instruments in LAMOST. It could provide uniform light output to the fibers, meet the requirements for the CCD camera measurement and was controlled by high-level observation system which could shut down during the telescope observation. The paper was introduced the back illuminated system design and different test for the light resource. After optimization, the effect illuminated system could compare the integrating sphere, meet the conditions of fiber position measurement.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Zengxiang Zhou, Zengxiang Zhou, Zhigang Liu, Zhigang Liu, Hongzhuan Hu, Hongzhuan Hu, Jianping Wang, Jianping Wang, Chao Zhai, Chao Zhai, Jiaru Chu, Jiaru Chu, } "Back-illuminate fiber system research for multi-object fiber spectroscopic telescope", Proc. SPIE 9912, Advances in Optical and Mechanical Technologies for Telescopes and Instrumentation II, 991258 (22 July 2016); doi: 10.1117/12.2231975; https://doi.org/10.1117/12.2231975
PROCEEDINGS
9 PAGES


SHARE
RELATED CONTENT

A testbed for simultaneous measurement of fiber near and far...
Proceedings of SPIE (September 23 2012)
Development of the Wide Field Grism Spectrograph 2
Proceedings of SPIE (September 29 2004)
Preparing first light of LAMOST
Proceedings of SPIE (July 16 2008)

Back to Top