16 August 2016 Radiation testing of CID arrays
Author Affiliations +
Abstract
Charge Injection Device technology has been widely used in radiation applications. Although the technology has excelled in ground applications that have been predominantly for radiation effects using gamma radiation, a Thermo Scientific CID8725D radiation hardened camera with CID imager has now been tested for effects due to proton and heavy ion irradiation to investigate viability for use in space applications.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Bryan Fodness, Bryan Fodness, Zoran Ninkov, Zoran Ninkov, Suraj Bhaskaran, Suraj Bhaskaran, Carey Beam, Carey Beam, } "Radiation testing of CID arrays", Proc. SPIE 9915, High Energy, Optical, and Infrared Detectors for Astronomy VII, 99152M (16 August 2016); doi: 10.1117/12.2233840; https://doi.org/10.1117/12.2233840