This paper describes the preliminary analysis and design of a water-cooled multilayer monochromator (MLM) system for the Illinois Institute of Technology’s BioCAT beamline at Argonne National Laboratory. The first substrate is designed to handle the heat load of an undulator beam with low tangential slope errors. The substrates will each have two multilayer coating strips to provide high flux 12 keV beams with either 0.5% or 1% spectral bandwidth. The new multilayer system which will be added to the beamline is expected to provide an increased photon flux of 50 to 100 times compared with the existing double crystal monochromator system and thus enhance beamline throughput and performance for applications where higher bandwidth is acceptable.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ali Khounsary, Anoop Chandrashekarappa, Anthony Llodra, Mikhail Antimonov, Carlo U. Segre, Sudhakar E. Nair, Thomas Irving, "Development of a multilayer monochromator system for the BioCAT beamline", Proc. SPIE 9963, Advances in X-Ray/EUV Optics and Components XI, 99630W (14 November 2016); doi: 10.1117/12.2238929; https://doi.org/10.1117/12.2238929
PROCEEDINGS
9 PAGES


SHARE
RELATED CONTENT

Sagittally focusing multilayers for wiggler beamlines
Proceedings of SPIE (January 05 2001)
Calibration of hard x ray (15 50 keV)...
Proceedings of SPIE (January 29 2004)
Tests Of Short Period X Ray Multilayer Mirrors Using A...
Proceedings of SPIE (December 16 1988)
Multilayers and crystal for a multi-bandpass monochromator
Proceedings of SPIE (September 03 2008)

Back to Top