Paper
4 October 2016 Arterial wall perfusion measured with photon counting spectral x-ray CT
Steven M. Jorgensen, Mark J. Korinek, Andrew J. Vercnocke, Jill L. Anderson, Ahmed Halaweish, Shuai Leng, Cynthia H. McCollough, Erik L. Ritman
Author Affiliations +
Abstract
Early atherosclerosis changes perfusion of the arterial wall due to localized proliferation of the vasa vasorum. When contrast agent passes through the artery, some enters the vasa vasorum and increases radiopacity of the arterial wall. Technical challenges to detecting changes in vasa vasorum density include the thin arterial wall, partial volume averaging at the arterial lumen/wall interface and calcification within the wall. We used a photon-counting spectral CT scanner to study carotid arteries of anesthetized pigs and micro-CT of these arteries to quantify vasa vasorum density. The left carotid artery wall was injected with autologous blood to stimulate vasa vasorum angiogenesis. The scans were performed at 25-120 keV; the tube-current-time product was 550 mAs. A 60 mL bolus of iodine contrast agent was injected into the femoral vein at 5mL/s. Two seconds post injection, an axial scan was acquired at every 3 s over 60 s (i.e., 20 time points). Each time point acquired 28 contiguous transaxial slices with reconstructed voxels 0.16 x 0.16 x 1 mm3. Regions-of-interest in the outer 2/3 of the arterial wall and in the middle 2/3 of the lumen were drawn and their enhancements plotted versus time. Lumenal CT values peaked several seconds after injection and then returned towards baseline. Arterial wall CT values peaked concurrent to the lumen. The peak arterial wall enhancement in the left carotid arterial wall correlated with increased vasa vasorum density observed in micro-CT images of the isolated arteries.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Steven M. Jorgensen, Mark J. Korinek, Andrew J. Vercnocke, Jill L. Anderson, Ahmed Halaweish, Shuai Leng, Cynthia H. McCollough, and Erik L. Ritman "Arterial wall perfusion measured with photon counting spectral x-ray CT", Proc. SPIE 9967, Developments in X-Ray Tomography X, 99670B (4 October 2016); https://doi.org/10.1117/12.2238817
Lens.org Logo
CITATIONS
Cited by 9 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Arteries

Computed tomography

X-ray computed tomography

Photon counting

X-rays

Blood

Sensors

Back to Top