While the method provided in Chapter 7 is quite useful in determining time to failure in the presence of water (100% relative humidity), most analysts will not have access to the value of B for any material, let alone a new one, without the dynamic fatigue test, but may have access to the value of N and hence N' from the literature. Of course, inert strength data may be readily attainable by test or vendor/supplier information.
|