1.IntroductionMethemoglobin is an abnormal type of hemoglobin that contains oxidized iron atoms in the ferric state and is incapable of transporting oxygen to body tissues.1,2 Elevated methemoglobin levels (methemoglobinemia) can cause tachycardia, stupor, and impaired respiration due to tissue hypoxia. Death may occur in humans when the methemoglobin level in the blood stream is .3 More common than the congenital form, acquired methemoglobinemia may be induced by a wide range of chemicals and drugs. Local anesthetics, such as topical benzocaine, antibiotics such as dapsone, and nitrites in well water or additives to preserve meat, can all lead to methemoglobinemia.4–6 Thus, measuring the methemoglobin level has extensive clinical applications. In addition to measuring the average concentration, measuring the spatial distribution of methemoglobin provides important information for the diagnosis and treatment of diseases. Methemoglobinemia secondary to topical anesthetics has been reported in many clinical contexts and is potentially lethal.7,8 Usually used as a treatment for methemoglobinemia, methylene blue can worsen the condition in individuals with endogenous glucose-6-phosphate dehydrogenase deficiency.9,10 In this case, fast measurement of the spatial distribution of methemoglobin around the area where anesthetics are applied enables surgeons to react quickly by revealing the concentration change of methemoglobin following the treatment. Moreover, measuring methemoglobin’s spatial distribution provides additional information for differential diagnoses in patients with mechanical airway obstruction, pulmonary embolus, or circulatory shock,4 and in infants with cyanotic congenital heart diseases or sepsis.5 Finally, spatial distribution measurements can potentially provide opportunities to study the role of methemoglobin in inflammation and atherosclerotic diseases.9 Current techniques for methemoglobin detection, including arterial blood gas analysis, pulse oximetry, and co-oximetry, are limited in various ways. Arterial blood gas analysis will show a normal partial pressure of oxygen even when the methemoglobin concentration is high because it measures only the dissolved oxygen, not the actual amount of oxygen bound to hemoglobin in blood.5,11 Pulse oximetry measures arterial blood oxygenation using two light sources of different wavelengths (typically 660 and 940 nm), which works well when only oxyhemoglobin and deoxyhemoglobin are present. However, methemoglobin absorbs light equally well at these two wavelengths, which drives the value of red-to-infrared ratio to one.12,13 Based on the algorism of pulse oximetry, a ratio of one corresponds to an oxygen saturation of 85%,11,13 which is an unreliable result at high levels of methemoglobin. In addition, at 660 nm, methemoglobin has a molar absorption coefficient similar to that of deoxyhemoglobin, which could also confound the measurement.11 Co-oximetry is a generally accurate method for measurement of methemoglobin, but the readings can also be falsely positive in the presence of methylene blue, which is commonly used for treatment.11,14 Furthermore, all of these conventional diagnostic modalities measure only the average concentration, not the spatial distribution, of methemoglobin. We still lack a technique that can spatially image the concentrations of methemoglobin quantitatively in vivo. Since it was first introduced in 2005, three-dimensional photoacoustic microscopy (PAM) has demonstrated its potential in structural and functional imaging.15–20 In PAM, a short-pulsed laser is used to irradiate the object. When the light is absorbed by the object, the resulting temperature rise leads to an initial pressure rise in proportion to the local energy deposition. The initial pressure rise then propagates as photoacoustic waves which can be detected by a focused ultrasonic transducer.21 Excitation at multiple optical wavelengths in PAM can provide spectral information concerning the optical absorption.22 So far, PAM has successfully detected a number of endogenous optical absorbers in vivo, such as oxyhemoglobin, deoxyhemoglobin, carboxyhemoglobin, bilirubin, and melanin.23–25 The motivation of this work is to quantitatively image methemoglobin distribution with PAM. We first demonstrated that our PAM system was able to differentiate methemoglobin from oxyhemoglobin and deoxyhemoglobin in bovine blood. A 3.1% root mean square error of prediction (RMSEP), which defines the accuracy of the measurement, was achieved for the measurements of methemoglobin in vitro. In addition, methemoglobin distributions were successfully detected in vessel-mimicking phantoms. Finally, the methemoglobin distribution in a mouse ear was imaged in vivo during a period of induction and recovery of methemoglobin. We showed for the first time that PAM can quantitatively image the spatial distribution of methemoglobin both in vitro and in vivo. 2.Material and Methods2.1.Experimental SystemAn optical-resolution PAM system26,27 was used to measure methemoglobin distribution, as shown in Fig. 1. The light source was a tunable dye laser (CBR-D, Sirah GmbH) pumped by an Nd:YLF laser (INNOSAB, Edgewave GmbH) at a 1 kHz pulse repetition rate with pulse width around 5 ns. 4-dicyanomethylene-2-methyl-6-p-dimethylaminostyryl-4H-pyran dissolved in ethanol was used to generate a laser beam with a wavelength tunable from 595 to 665 nm. The laser beam was focused by a lens, filtered by a pinhole, and reflected by a mirror toward an objective lens to be focused into the object. An acoustic-optical beam combiner containing two prisms with a layer of silicone oil in between provided the acoustic optical coaxial alignment. Then a wideband ultrasonic transducer (V214-BC, Panametrics-NDT Inc.) with a center frequency around 50 MHz (70% two-way bandwidth) detected the acoustic signals. A spherically focused acoustic lens, with a focal distance around 6 mm, was placed confocally with the optical objective lens. A depth-resolved one-dimensional (1-D) photoacoustic A-line signal was obtained from each laser pulse. The Hilbert transformation was applied to the 1-D photoacoustic signals for envelope extraction. By raster scanning the object in two dimensions and performing maximum amplitude projections (MAP) of the A-line signals, a two-dimensional MAP PAM image of the sample was obtained. 2.2.Phantom PreparationsSodium nitrite (237213-500G, Sigma-Aldrich) powder was mixed with lysed bovine blood (905, Quad-Five) to induce methemoglobin formation in the samples. To induce a level of 100% methemoglobin, 24.3 g sodium nitrite powder was added to 50 ml of bovine blood. Then blood samples with methemoglobin concentrations of 20, 40, 60, and 80% were obtained by mixing 2, 4, 6, and 8 ml of the 100% methemoglobin blood with 8, 6, 4, and 2 ml of pure bovine blood, respectively. The mixtures were then separately injected into microtubes (60985–700, VWR) made of platinum-cured silicone, with inner diameters and outer diameters, to mimic blood with different methemoglobin concentrations in blood vessels. 2.3.In Vivo Methemoglobin Induction in a Mouse ModelTo induce methemoglobin formation in a mouse model, of the well-mixed sodium nitrite solution () was injected through the jugular vein of a mouse. The volume and concentration were calculated based on the Kohn’s model.28 Subsequently, the blood vessels of the mouse ear were imaged by the PAM system at multiple optical wavelengths. 2.4.Quantification of Methemoglobin, Oxyhemoglobin, and Deoxyhemoglobin ConcentrationsThe absorbance () of the sample measured by a spectrophotometer can be expressed as where , , and are the concentrations of oxyhemoglobin, deoxyhemoglobin, and methemoglobin, respectively; , , and are the wavelength-dependent molar absorption coefficients of oxyhemoglobin, deoxyhemoglobin, and methemoglobin, respectively. In theory, three wavelengths are enough to calculate the concentrations of all three forms of hemoglobin. The methemoglobin percentage can be calculated by , where is the total hemoglobin concentration.The photoacoustic amplitude can be described as where is a sample-independent constant factor, including the Grueneisen parameter, heat conversion percentage, and other minor contributors.29 Similar to how the methemoglobin percentage is calculated with the spectrophotometric measurements, the methemoglobin percentage can be calculated with photoacoustic measurements acquired at three wavelengths.Given both the systematic and random errors, we can define the measurement accuracy by RMSEP.23 where represents the systematic error and represents the random error: where , , and are the preset concentration, average measured concentration, and the standard deviation of the ’th sample, respectively, and is the total number of samples.3.Results3.1.Photoacoustic Spectra and Measurement AccuracyAs shown by the molar extinction spectra30,31 in Fig. 2(a), methemoglobin has stronger absorption than oxyhemoglobin and deoxyhemoglobin, from 610 to 630 nm. Four phantoms with different methemoglobin concentrations (20, 40, 60, and 80%) were first measured by a spectrophotometer (Cary 50 Bio UV/Visible, VARIAN). The measured absorption coefficient shows an increasing trend in the chosen range (610 to 630 nm) as the methemoglobin level increases [Fig. 2(b)]. Then the four samples were measured by the PAM system. As expected, the intensity of the photoacoustic signals increased from the 20% methemoglobin to the 80% methemoglobin [Fig. 2(c)]. The trends of the photoacoustic signals from 610 to 630 nm for each concentration also agree with the results from the spectrophotometer. Additionally, the percentage of methemoglobin and oxyhemoglobin measured by the PAM system all fit the preset concentrations well [Fig. 2(d)]. The 3.1% RMSEP of the concentration also validated that our in vitro measurements were relatively accurate. 3.2.Quantitative Methemoglobin Imaging in PhantomsMethemoglobin distributions were imaged by PAM in tissue-mimicking phantoms. Samples with different induced methemoglobin levels were prepared with the method described above. Five microtubes filled with bovine blood having average methemoglobin concentrations of 23, 41, 58, 76, and 89% were used to mimic blood vessels with blood of different methemoglobin levels. The same wavelengths were selected for PAM imaging, with a scanning area of 4 mm by 2 mm. The normalized PAM images obtained at each wavelength are shown in Fig. 3(a). The methemoglobin distribution is calculated for each pixel in the coregistered multiwavelength images. To reduce the impact of noise, we only analyzed those pixels with signal-to-noise ratio higher than five. Based on these multiwavelength images, the calculated distributions of methemoglobin concentrations are shown in Fig. 3(b). We showed that the PAM results averaged within each tube accorded well with the preset concentrations, as shown in Fig. 3(c). The results in Fig. 3 demonstrate that PAM is capable of imaging the concentration and distribution of methemoglobin in blood. 3.3.Methemoglobin Imaging In Vivo in a Mouse EarFinally, to demonstrate PAM imaging of methemoglobin in vivo, methemoglobin formation was induced in a mouse with sodium nitrite solution.28 The mouse ear was imaged by PAM consecutively for to include both the methemoglobin-induction activity and the recovery activity of the mouse’s self-reductive systems. An area of 4 mm by 4 mm was first scanned to show the blood vessels on the mouse’s ear [Fig. 4(a)] with a wavelength of 610 nm; then a 1 mm by 0.6 mm area was imaged at the three wavelengths (610, 620, and 630 nm) once every 4 min, to monitor the change in methemoglobin level over the 105 min [the rectangular area in Fig. 4(a)]. As shown in Fig. 4(b1), methemoglobin percentage was low in the blood before the injection of sodium nitrite solution. We observed an increase of methemoglobin percentage due to the injection of sodium nitrite solution [Fig. 4(b2)] followed by a decrease of the methemoglobin percentage due to the self-reductive mechanism [Figs. 4(b3) and 4(b4)]. The time course of the average methemoglobin and oxyhemoglobin percentages measured by PAM [Fig. 4(c)] were in accordance with the prediction of the Kohn model.28 4.Discussions and ConclusionsWithin the chosen range of wavelengths in this work (from 610 to 630 nm), the absorption in blood vessels mainly originates from oxyhemoglobin, deoxyhemoglobin, and methemoglobin. For the three absorbers in this experiment, three optical wavelengths are enough to differentiate methemoglobin from oxyhemoglobin and deoxyhemoglobin. While using more wavelengths can provide additional data for a more accurate least squares fit, the measurement would take longer. The choice between accuracy and speed depends on the application of the technique. In healthy humans, the level of methemoglobin is very low, so the oxyhemoglobin and deoxyhemoglobin absorb most of the optical energy. In this case, PAM alone may not be able to provide accurate absolute quantification. However, it can complement other traditional measuring techniques to image the spatial distribution of methemoglobin. To the best of our knowledge, this is the first study to use PAM to quantitatively image the methemoglobin in vivo. The methemoglobin concentration and distribution were imaged by PAM in tissue-mimicking phantoms at multiple wavelengths. In the phantom study, the RMSEP of the concentration was calculated to be 3.1%. We also measured the methemoglobin concentration change in vivo after induction of methemoglobinemia in a mouse. After intravenous injection of sodium nitrite solution, the methemoglobin level measured in the blood vessels of the mouse ear increased from 5 to 10% and peaked after injection. The methemoglobin concentration gradually decreased to the normal level by the end of the measurement. This finding is in accordance with the prediction of the Kohn model.28 Our study demonstrated PAM’s capability to quantify methemoglobin levels in vivo, with potential clinical applications. AcknowledgmentsThe authors gratefully acknowledge the suggestions made by the reviewers of this manuscript, by Professor James Ballard and by Professor Sandra Matteucci at Washington University in St. Louis. This work was supported in part by National Institutes of Health grants DP1 EB016986, R01 CA186567, U01 NS090579, R01 EB016963, R01 EB010049, R01 CA157277, S10 RR028864, S10 RR026922, and R01 CA159959 as well as National Science Foundation grant 1255930. L.V.W. has a financial interest in Microphotoacoustics Inc., and Endra Inc., which, however, did not support this work. ReferencesN. E. Camp,
“Methemoglobinemia,”
J. Emerg. Nurs., 33
(2), 172
–174
(2007). http://dx.doi.org/10.1016/j.jen.2006.11.007 0099-1767 Google Scholar
S. Bradberry,
“Methaemoglobinaemia,”
Medicine, 40
(2), 59
–60
(2012). http://dx.doi.org/10.1016/j.mpmed.2011.11.011 MEDIAV 0025-7974 Google Scholar
H. U. Rehman,
“Methemoglobinemia,”
West. J. Med., 175
(3), 193
–196
(2001). http://dx.doi.org/10.1136/ewjm.175.3.193 WJMDA2 0093-0415 Google Scholar
J. A. Cortazzo and A. D. Lichtman,
“Methemoglobinemia: a review and recommendations for management,”
J. Cardiothorac. Vasc. Anesth., 28
(4), 1055
–1059
(2014). http://dx.doi.org/10.1053/j.jvca.2013.02.005 JCVAEK 1053-0770 Google Scholar
R. O. Wright, W. J. Lewander and A. D. Woolf,
“Methemoglobinemia: etiology, pharmacology, and clinical management,”
Ann. Emerg. Med., 34
(5), 646
–656
(1999). http://dx.doi.org/10.1016/S0196-0644(99)70167-8 AEMED3 0196-0644 Google Scholar
J. N. Lukens,
“Landmark perspective: the legacy of well-water methemoglobinemia,”
JAMA, 257
(20), 2793
–2795
(1987). http://dx.doi.org/10.1001/jama.1987.03390200133028 JAMAAP 0098-7484 Google Scholar
D. R. Lorelli, D. E. Morris and J. W. LewisJr.,
“Drug-induced methemoglobinemia during thoracoscopic lung biopsy,”
Ann. Thorac. Surg., 71
(2), 703
–705
(2001). http://dx.doi.org/10.1016/S0003-4975(00)02175-5 ATHSAK 0003-4975 Google Scholar
R. Gutta and P. J. Louis,
“Methemoglobinemia—an unusual cause of intraoperative hypoxia,”
Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endod., 103
(2), 197
–202
(2007). http://dx.doi.org/10.1016/j.tripleo.2006.05.006 1079-2104 Google Scholar
J. Umbreit,
“Methemoglobin—it’s not just blue: a concise review,”
Am. J. Hematol., 82
(2), 134
–144
(2007). http://dx.doi.org/10.1002/(ISSN)1096-8652 AJHEDD 1096-8652 Google Scholar
S. Patnaik et al.,
“Methylene blue unresponsive methemoglobinemia,”
Indian J. Crit. Care Med., 18
(4), 253
–255
(2014). http://dx.doi.org/10.4103/0972-5229.130582 IJCCF4 0972-5229 Google Scholar
E. D. Chan, M. M. Chan and M. M. Chan,
“Pulse oximetry: understanding its basic principles facilitates appreciation of its limitations,”
Respir. Med., 107
(6), 789
–799
(2013). http://dx.doi.org/10.1016/j.rmed.2013.02.004 RMEDEY 0954-6111 Google Scholar
A. Jubran,
“Pulse oximetry,”
Crit. Care, 3
(2), R11
–R17
(1999). http://dx.doi.org/10.1186/cc341 1364-8535 Google Scholar
L. M. Schnapp and N. H. Cohen,
“Pulse oximetry. Uses and abuses,”
Chest, 98
(5), 1244
–1250
(1990). http://dx.doi.org/10.1378/chest.98.5.1244 CHETBF 0012-3692 Google Scholar
J. Lee et al.,
“Noninvasive in vivo monitoring of methemoglobin formation and reduction with broadband diffuse optical spectroscopy,”
J. Appl. Physiol., 100
(2), 615
–622
(2006). http://dx.doi.org/10.1152/japplphysiol.00424.2004 JAPYAA 0021-8987 Google Scholar
K. Maslov, G. Stoica and L. V. Wang,
“In vivo dark-field reflection-mode photoacoustic microscopy,”
Opt. Lett., 30
(6), 625
–627
(2005). http://dx.doi.org/10.1364/OL.30.000625 OPLEDP 0146-9592 Google Scholar
H. F. Zhang et al.,
“Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging,”
Nat. Biotechnol., 24
(7), 848
–851
(2006). http://dx.doi.org/10.1038/nbt1220 NABIF9 1087-0156 Google Scholar
K. Maslov et al.,
“Optical-resolution photoacoustic microscopy for in vivo imaging of single capillaries,”
Opt. Lett., 33
(9), 929
–931
(2008). http://dx.doi.org/10.1364/OL.33.000929 OPLEDP 0146-9592 Google Scholar
L. V. Wang,
“Multiscale photoacoustic microscopy and computed tomography,”
Nat. Photonics, 3
(9), 503
–509
(2009). http://dx.doi.org/10.1038/nphoton.2009.157 1749-4885 Google Scholar
S. Hu and L. V. Wang,
“Photoacoustic imaging and characterization of the microvasculature,”
J. Biomed. Opt., 15
(1), 011101
(2010). http://dx.doi.org/10.1117/1.3281673 JBOPFO 1083-3668 Google Scholar
L. V. Wang and S. Hu,
“Photoacoustic tomography: in vivo imaging from organelles to organs,”
Science, 335
(6075), 1458
–1462
(2012). http://dx.doi.org/10.1126/science.1216210 SCIEAS 0036-8075 Google Scholar
L. V. Wang and H. Wu, Biomedical Optics: Principles and Imaging, 1st ed.Wiley, Hoboken, NJ
(2007). Google Scholar
J. Yao et al.,
“Label-free oxygen-metabolic photoacoustic microscopy in vivo,”
J. Biomed. Opt., 16
(7), 076003
(2011). http://dx.doi.org/10.1117/1.3594786 JBOPFO 1083-3668 Google Scholar
Y. Zhou et al.,
“Photoacoustic microscopy of bilirubin in tissue phantoms,”
J. Biomed. Opt., 17
(12), 126019
(2012). http://dx.doi.org/10.1117/1.JBO.17.12.126019 JBOPFO 1083-3668 Google Scholar
Y. Zhou et al.,
“Handheld photoacoustic microscopy to detect melanoma depth in vivo,”
Opt. Lett., 39
(16), 4731
–4734
(2014). http://dx.doi.org/10.1364/OL.39.004731 OPLEDP 0146-9592 Google Scholar
Z. Chen, S. Yang and D. Xing,
“In vivo detection of hemoglobin oxygen saturation and carboxyhemoglobin saturation with multiwavelength photoacoustic microscopy,”
Opt. Lett., 37
(16), 3414
–3416
(2012). http://dx.doi.org/10.1364/OL.37.003414 OPLEDP 0146-9592 Google Scholar
P. Hai et al.,
“Near-infrared optical-resolution photoacoustic microscopy,”
Opt. Lett., 39
(17), 5192
–5195
(2014). http://dx.doi.org/10.1364/OL.39.005192 OPLEDP 0146-9592 Google Scholar
Y. Zhou, J. Yao and L. V. Wang,
“Optical clearing-aided photoacoustic microscopy with enhanced resolution and imaging depth,”
Opt. Lett., 38
(14), 2592
–2595
(2013). http://dx.doi.org/10.1364/OL.38.002592 OPLEDP 0146-9592 Google Scholar
M. C. Kohn et al.,
“Pharmacokinetics of sodium nitrite-induced methemoglobinemia in the rat,”
Drug Metab. Dispos., 30
(6), 676
–683
(2002). http://dx.doi.org/10.1124/dmd.30.6.676 DMDSAI 0090-9556 Google Scholar
Y. Zhou et al.,
“Calibration-free absolute quantification of particle concentration by statistical analyses of photoacoustic signals in vivo,”
J. Biomed. Opt., 19
(3), 037001
(2014). http://dx.doi.org/10.1117/1.JBO.19.3.037001 JBOPFO 1083-3668 Google Scholar
L. L. Randeberg et al.,
“Methemoglobin formation during laser induced photothermolysis of vascular skin lesions,”
Lasers Surg. Med., 34
(5), 414
–419
(2004). http://dx.doi.org/10.1002/(ISSN)1096-9101 LSMEDI 0196-8092 Google Scholar
S. Prahl,
“Optical absorption of hemoglobin,”
http://omlc.org/spectra/hemoglobin/ Google Scholar
BiographyMin Tang is currently a senior undergraduate student in the Department of Biomedical Engineering at Washington University in St. Louis. Her research interests include tissue engineering and its related applications. Yong Zhou is currently a graduate student in biomedical engineering at Washington University in St. Louis, under the supervision of Dr. Lihong V. Wang, Gene K. Beare distinguished professor. His research focuses on the development of photoacoustic imaging systems. Ruiying Zhang received her BS in optical information science and technology from Wuhan University in Hubei, China. She is currently a PhD student in the Department of Biomedical Engineering at Washington University in St. Louis. Her research interests include optical and photoacoustic imaging with biomedical applications. Lihong Wang, the Beare distinguished professor at Washington University, has published 420 journal articles (, ) and delivered 400 keynote/plenary/invited talks. His laboratory published the first functional photoacoustic CT and three-dimensional photoacoustic microscopy. He received the Goodman Award for his Biomedical Optics textbook, NIH Director’s Pioneer Award, OSA Mees Medal, IEEE Technical Achievement and Biomedical Engineering Awards, SPIE Britton Chance Biomedical Optics Award, and an honorary doctorate from Lund University, Sweden. |