1.IntroductionGenerally, it is a difficult task for microscopic observation to study specimens in or covered with a turbid medium. This is particularly important if specimen changes are to be observed, such as activity and reactions of live cells. In this case, something more than phase contrast imaging is required. It has already been demonstrated that imaging through scattering media and turbid liquids is possible by digital holography.1–11 Separate holographic methods have been used for imaging through different turbid media, such as rotating diffuser,1 onion cell layer and cornea,2 milk,3,4 ground-glass diffuser,5–7 intralipid suspension,8 and biological tissue.9 However, a coherence-controlled holographic microscope6 (CCHM) invented and built by our group provided low-coherence mode with improved coherence gate effect7 (CGE). First, we examined this optical property in model situations.7,12 The positive experience obtained allowed the investigation of how preparation of biologically active phospholipids (BAPs) available only in turbid emulsion affects the cancer cells. BAPs are commonly considered to have positive influence on health.13 For the BAPs preparation, we used the anticancer activity that was already proved in the animal model in vivo and also in vitro.14 However, in the previous study, the mode of cancer cell death elicited by BAPs could not be established. This is an important aspect from the therapeutics point of view. Therefore, the aim of this study was to identify the course of events caused by the BAPs preparation that eventually leads to the determinantion of the cell death type. 2.Material and Methods2.1.Coherence-Controlled Holographic MicroscopeCCHM is an off-axis holographic system that interferometrically measures the optical phase shift of light passing through the specimen relative to the reference beam.6,15 The cell is a convenient thin and transparent specimen for this method. Nonaqueous components of the cell have similar specific refractive increments16 higher than water. Then, the amount of phase shift per pixel corresponds to cell dry mass distribution.16 From the quantitative information about phase shift in each pixel, the total dry mass of a whole cell can be calculated and expressed in picograms.17 Moreover, the changes of mass distribution with time bring invaluable information about cell motility. Consequently, the leading noninvasive application of CCHM is the use of quantitative phase imaging (QPI) for measurement of dry mass changes during long-term evaluation of the living cells activity18,19 and exploitation of CGE for imaging in turbid milieu. Optical setup of CCHM is shown in Fig. 1(a). The light from a light source (LS) passes through the aperture stop (AS) and interference filter (IF). These two elements enable selection of the degree of light coherence. Adjustable size of the aperture stop controls the spatial coherence, which substantially influences the imaging characteristics in transmission mode. Lateral resolution is better with a larger radius of the aperture stop, which corresponds to lower spatial coherence. Wider passband of the interference filter causes lower temporal coherence. These assumptions are fully described by Chmelik et al.12 and are generalized by Leith et al.20 As a result, imaging in transmitted-light setup is substantially affected by spatial coherence rather than temporal coherence (in contrast to optical coherence tomography2). Therefore, the interference filter, (10 nm FWHM), was chosen as a nonphototoxic wavelength for live cell imaging. After beam splitting, light passes through the achromatic interferometer [Fig. 1(a)] consisting of two separated optical paths—the object and the reference arm. Both arms are equipped by identical optical setups: condensers (C), objectives (O), and tube lenses (TL). Off-axis holography is based on utilizing the first order of the diffraction grating (DG),12 which is placed in the reference arm. Object planes (SP, RO) and diffraction grating are optically conjugated with the output plane (OP). The interference fringe pattern, called a hologram in the output plane, is captured by CCD detector. Critical specification of the optical elements requires precise selection of condenser and objective lenses to the setup to be optically identical. Following parameters of the system are crucial: identical optical path length in both arms and zero mutual shift of the object and reference beams in the output plane. These parameters are adjusted before every measurement, and they are maintained automatically to get the highest contrast of the interference fringes (i.e., imaging signal). Observation through a scattering or turbid media [Fig. 1(b)] is possible due to CGE.6,7,12 Due to the possibility of using tunable degree of temporal and spatial coherence of light source,6 CCHM enables only the ballistic light (light that goes through specimen without being scattered) to interfere with the reference wavefront. The light that is scattered by specimen does not contribute to interference and, therefore, is filtered. Consequently, there is a limited contribution of light scattered in out-of-focus planes of the specimen to the image. As a result, an improved in-focus image contrast arises and investigation of the intracellular dynamics is made possible. 2.2.Cell Culture and TreatmentsHuman colorectal adenocarcinoma cell line DLD-1 (ATCC® CCL221™), kindly provided by AREKO Ltd., Prague, Czech Republic, and human breast adenocarcinoma cell line MCF-7 were used. Cells were cultivated at 37°C in a humidified incubator with 3.5% in standard medium (Eagle’s minimum essential medium based on Hanks balanced salt solution enriched with nonessential amino acids and 1 mM sodium pyruvate, with 1 g , 10% calf serum, 80 mM gentamicin, and 2 mM L-glutamine). Observation medium F10 was prepared without phenol red. 20 mM TES (N-[tris(hydroxymethyl)methyl]-2-aminoethanesulfonic acid, 2-[(2-hydroxy-1, 1-bis(hydroxymethyl)ethyl)amino]ethanesulfonic acid) buffer (Sigma T5691) was used to set a pH of 7.4. For microscopy, trypsinized cells were seeded in subconfluent density and hermetically closed in the static observation chamber (Figs. 2, 3, 5, and 6), which consists of two coverslips and an annular ring spacer. The volume of the chamber is 0.7 ml with 4 mm inner height for BAPs preparation in emulsion, which constitutes the strong diffusing layer between the coverslips. For observation in perfusion mode with online changes of medium (Fig. 4), the -Slide I Leuer flow chamber (Ibidi Company) with 0.8 mm inner height was used. Cells were measured under standard laboratory conditions. A temperature of 37°C was constantly maintained in the environmental box for CCHM. BAPs were provided by AREKO Ltd., Prague, Czech Republic. Sodium dichloroacetate (DCA, Sigma 347795) as a potential anticancer drug21 was dissolved in phosphate buffered saline (pH 7.4), filtered, and diluted in cultivation medium. 2.3.Criteria for Cell Death EvaluationDynamic morphology of the treated cells that were observed led to the determination of cell death mode.22,23 Apoptosis, a programmed cell death, manifest features of dynamic morphology as a retraction of the cell into spherical shape that shows exaggerated zeiosis, which is a fast appearing and disappearing protrusions bulging at the tips and eventually splitting off the cell to form apoptotic bodies. Complete dismantling of the cell body is a desired trait of harmless removal of cell residues, because this does not initiate inflammation. Necrosis is an accidental cell death; dynamic morphology shows a variety of shape irregularities and damage to membrane integrity, such as blebs or blisters formation, which while bursting release cytoplasmic material, thus stimulating inflammatory response. Assessment of the cell death mode was derived from the course of dynamic morphology events, not merely from appreciation of cell morphology registered by a single image. 2.4.Image Acquisition and ProcessingIndividual holograms are captured by camera Ximea MR4021MC-BH (maximum speed capture 5 fps by full resolution of ). Captured holograms are processed in real time during the measuring process or in postprocessing procedure on PC (NVIDIA GeForce GTX 660, Intel Core i7, RAM 8 GB). The reconstruction of phase images from a captured hologram is based on carrier removal in the Fourier plane,24 and it is performed using self-developed software. During phase image processing, it is necessary to carry out the unwrapping procedure25 (Goldstein’s branch-cut) and background compensation26 based on least-squares fitting. These algorithms compensate deformation in phase images and allow single-cell segmentation and cell tracking in time-lapse sequence. Reprocessing speed comes up to 25 fps (GPU accelerated). All images in this paper represent resulting quantitative phase (QPI) captured by CCHM, and they have been adjusted to optimal contrast representation. 3.Results and Discussion3.1.Scattering Layer: Difference in Image Quality with Low and High Coherence of IlluminationAs mentioned earlier, reduction of spatial and temporal coherence allows for coherence gating. Spatially and temporally low-coherent illumination versus coherent illumination was used to obtain images of the same field of view. Figure 2 shows human breast adenocarcinoma cells MCF-7 embedded in 0.1% BAPs emulsion (4 mm layer thickness). CCHM equipped with a halogen lamp provides noninvasive illumination of the sample not exceeding at the sample plane. In addition, the object beam was weakened through the turbid medium (scattering coefficient ), and a neutral density filter was used in the reference arm to equilibrate intensity in both arms. The suppression of parasitic interferences is demonstrated in the case of low-coherent illumination even with single-shot acquisition [Fig. 2(a)] when a halogen lamp was used (interference filter , 10 nm FWHM, coherence width , and coherence length calculated in the object plane27). For demonstration of imaging with maximum coherence, it is necessary to use a laser because it is not possible to obtain point aperture stop in the setup. Therefore, the WhiteLase Supercontinuum laser with acousto-optic tunable filter (, 4 nm FWHM) was used [Figs. 2(b) and 2(c)]. The phase image made by the laser without averaging [Fig. 2(b)] contains phase residues,24 which preclude the successful phase unwrapping procedure during image processing. The average of 10 images [Fig. 2(c)] was used to reduce speckle noise and multiple scattering on quasistatic turbid microfluidics of phospholipid particles.4 Spatial noise11 (fluctuations among the pixels in one image) was calculated as the standard deviation of pixels from the area that does not contain cells (background) in Fig. 1: panel (a) (12 nm), panel (b) (113 nm), panel (c) (40 nm). This demonstrates that CCHM, especially if using low-coherent light, enables clear investigation of intracellular dynamics and reactions of cells to the treatment in high imaging quality and resolution (lateral resolution 900 nm by use of objectives). 3.2.Cell Reactions to Biologically Active Phospholipids in Static ModeColony of human colorectal adenocarcinoma cells DLD-1 (Fig. 3) offers two social situations for cells: First, it concerns cells along the colony edge, which are partly free from contacts with neighbor cells, and second, it deals with fully protected cells inside the colony. It was interesting to learn if there is a difference in the speed and efficiency of the BAPs-mediated damage. From Fig. 3, it is clear that cells around the edge were hit first, and the injury penetrated beyond them to steadily affect the whole colony. Considering this, it is not beyond reason that we in fact managed to mimic a similar course of events in an in vivo situation. Then, it may be worth considering to test screened anticancer drugs for their activity against in vitro colonies of growing and stationary cancer cells. 3.3.Cell Reactions to Biologically Active Phospholipids in Perfusion ModeCells of human breast adenocarcinoma line MCF-7 were planned to be repeatedly exposed to 0.5% BAPs in culture medium to see the course of events leading up to cell death (Fig. 4). In this way, necrosis or apoptosis can be determined. In Fig. 4, cells first show increasing of the fine granularity of cytoplasm and the coarse granularity around the nuclear membrane, then cessation of oscillating motion of perinuclear granules signals an irreversible step to cell death before the second application of BAPs [Fig. 4(e)]. Progressive deterioration of cells is speeded up by second BAPs challenge. This makes cells begin fast retraction due to rapidly releasing residual attachment to the culture substratum accompanied by an increasing amount of cell debris flowing in the medium. Loose cells, debris, and dead cells were washed out from the remaining cells. Final damage to the cell membrane is manifested by vigorous formation of large and bursting blisters leading to cell destruction by necrotic cell death. 3.4.Details of Intracellular Reactions to Biologically Active PhospholipidsHuman colorectal adenocarcinoma cells DLD-1 treated with emulsion of 0.15% BAPs in culture medium and observed with objective lens , NA 0.95 (Fig. 5), served a comparison with the effect of BAPs on MCF-7 cells. Again, decoration of nuclear membrane revealed the start of nuclear membrane indentation followed by cell body retractions, with decreasing cell integrity leading again to necrotic cell death. 3.5.Pilot Experiment: Biologically Active Phospholipids in Combination with DichloroacetateCCHM CGE offers an intriguing option of revealing the course of cell reactions to any drugs added to turbid media, which would otherwise remain obscure because only the end result will be seen. The most interesting aspect of these drug combinations is uncovering a putative synergism against cancer cells. We are interested in learning if BAPs-caused necrosis could be modified to apoptosis, which is the desired cancer cell-induced death by therapeutic intervention. For this purpose, 0.03% BAPs emulsion was used with the addition of 20 mM DCA to treat DLD-1 cells (Fig. 6). This is because DCA has been the focus of anticancer activity for some time28 and is shown to induce apoptosis in colorectal adenocarcinoma cells.29 In spite of controverting reports,30 after recent results,31,32 DCA is being reconsidered for its anticancer activity. Regardless of technical feasibility, an expected contribution of DCA to the final damage to cells has not been observed yet. However, the methods of ongoing investigations will have to be further perfected. 4.ConclusionCCHM, by providing CGE, makes single-shot registration of live cell activity in diffusive milieu possible. This advantage was used to determine the way BAPs have caused cancer cell death, whether programmed or accidental. In consequence, necrosis was identified as the mode of cell death elicited by BAPs preparation. We also attempted to examine possible synergism between BAPs and another drug added into the emulsion. In this case, it was DCA. The result of our preliminary experiment did not show any contribution of DCA to cell damage, at least at morphological level. However, using the technology for such examination was proven possible. This indicates a feasible practice for revealing cell activities that otherwise will remain unobserved. AcknowledgmentsThis work was supported by the project Excellent Teams (CZ.1.07/2.3.00/30.0005) from the European Social Fund, by CEITEC—Central European Institute of Technology (CZ.1.05/1.1.00/02.0068) from the European Regional Development Fund, by Czech Science Foundation (15-14612S), and by a Specific Research grant (FSI/STI-J-15-2752) of Brno University of Technology. ReferencesM. Tziraki et al.,
“Photorefractive holography for imaging through turbid media using low coherence light,”
Appl. Phys., 70
(1), 151
–154
(2000). http://dx.doi.org/10.1007/s003400050023 Google Scholar
P. Massatsch et al.,
“Time-domain optical coherence tomography with digital holographic microscopy,”
Appl. Opt., 44
(10), 1806
–1812
(2005). http://dx.doi.org/10.1364/AO.44.001806 APOPAI 0003-6935 Google Scholar
S. Li and J. Zhong,
“Dynamic imaging through turbid media based on digital holography,”
J. Opt Soc. Am, 31
(3), 480
–486
(2014). http://dx.doi.org/10.1364/JOSAA.31.000480 Google Scholar
V. Bianco et al.,
“Clear coherent imaging in turbid microfluidics by multiple holographic acquisitions,”
Opt. Lett., 37
(20), 4212
–4214
(2012). http://dx.doi.org/10.1364/OL.37.004212 OPLEDP 0146-9592 Google Scholar
G. Indebetouw and P. Klysubun,
“Imaging through scattering media with depth resolution by use of low-coherence gating in spatiotemporal digital holography,”
Opt. Lett., 25
(4), 212
–214
(2000). http://dx.doi.org/10.1364/OL.25.000212 OPLEDP 0146-9592 Google Scholar
T. Slaby et al.,
“Off-axis setup taking full advantage of incoherent illumination in coherence-controlled holographic microscope,”
Opt. Express, 21
(12), 14747
–14762
(2013). http://dx.doi.org/10.1364/OE.21.014747 Google Scholar
M. Lostak et al.,
“Coherence-controlled holographic microscopy in diffuse media,”
Opt. Express, 22
(4), 4180
–4195
(2014). http://dx.doi.org/10.1364/OE.22.004180 OPEXFF 1094-4087 Google Scholar
Y. Pan, R. Birngruber and R. Engelhardt,
“Contrast limits of coherence-gated imaging in scattering media,”
Appl. Opt., 36
(13), 2979
–2983
(1997). http://dx.doi.org/10.1364/AO.36.002979 APOPAI 0003-6935 Google Scholar
E. Leith et al.,
“Imaging through scattering media with holography,”
J. Opt. Soc. Am., 9
(7), 1148
–1153
(1992). http://dx.doi.org/10.1364/JOSAA.9.001148 JOSAAH 0030-3941 Google Scholar
M. Paturzo et al.,
“Microscopy imaging and quantitative phase contrast mapping in turbid microfluidic channels by digital holography,”
Lab Chip, 12
(17), 3073
–3076
(2012). http://dx.doi.org/10.1039/c2lc40114b LCAHAM 1473-0197 Google Scholar
G. Popescu, Quantitative Phase Imaging of Cells and Tissues, McGraw Hill, New York
(2011). Google Scholar
R. Chmelik et al.,
“The role of coherence in image formation in holographic microscopy,”
Prog. Opt., 59
(1), 267
–336
(2014). http://dx.doi.org/10.1016/B978-0-444-63379-8.00005-2 POPTAN 0079-6638 Google Scholar
D. Kullenberg et al.,
“Health effects of dietary phospholipids,”
Lipids Health Dis., 11
(3),
(2012). Google Scholar
V. Karafiat, P. Vesely and M. Dvorak,
“Egg yolk phospholipids enriched with 1-O-Octadecyl-2-Oleoyl-sn-Glycero-3-Phospho-(N-Palmitoyl) ethanolamine inhibit development of experimentally induced tumours,”
Folia Biol., 60
(5), 220
–227
(2014). Google Scholar
P. Kolman and R. Chmelik,
“Coherence-controlled holographic microscope,”
Opt. Express, 18
(21), 21990
–22003
(2010). http://dx.doi.org/10.1364/OE.18.021990 OPEXFF 1094-4087 Google Scholar
H. G. Davies et al.,
“The use of the interference microscope to determine dry mass in living cells and as a quantitative cytochemical method,”
J. Microsc. Sci., s3-95 271
–304
(1954). Google Scholar
A. F. Brown and G. A. Dunn,
“Microinterferometry of the movement of dry matter in fibroblasts,”
J. Cell Sci., 92
(3), 379
–389
(1989). JNCSAI 0021-9533 Google Scholar
H. Janeckova, P. Vesely and R. Chmelik,
“Proving tumour cells by acute nutritional/energy deprivation as a survival threat: a task for microscopy,”
Anticancer Res., 29
(6), 2339
–2345
(2009). ANTRD4 0250-7005 Google Scholar
B. Rappaz et al.,
“Noninvasive characterization of the fission yeast cell cycle by monitoring dry mass with digital holographic microscopy,”
J. Biomed. Opt., 14
(3), 034049
(2009). http://dx.doi.org/10.1117/1.3147385 JBOPFO 1083-3668 Google Scholar
E. N. Leith et al.,
“Optical sectioning by holographic coherence imaging: a generalized analysis,”
J. Opt. Soc. Am. A, 20
(2), 380
–387
(2003). http://dx.doi.org/10.1364/JOSAA.20.000380 JOSAAH 0030-3941 Google Scholar
S. Shahrzad et al.,
“Sodium dichloroacetate (DCA) reduces apoptosis in colorectal tumor hypoxia,”
Cancer Lett., 297
(1), 75
–83
(2010). http://dx.doi.org/10.1016/j.canlet.2010.04.027 CALEDQ 0304-3835 Google Scholar
J. Balvan et al.,
“Multimodal holographic microscopy: distinction between apoptosis and oncosis,”
PLoS One, 10
(3), e0121674
(2015). http://dx.doi.org/10.1371/journal.pone.0121674 POLNCL 1932-6203 Google Scholar
P. Golstein and G. Kroemer,
“Cell death by necrosis: towards a molecular definition,”
Trends Biochem. Sci, 32
(1), 37
–43
(2007). http://dx.doi.org/10.1016/j.tibs.2006.11.001 TBSCDB 0968-0004 Google Scholar
T. Kreis,
“Digital holographic interference-phase measurement using the Fourier-transform method,”
J. Opt. Soc. Am. A, 3
(6), 847
–855
(1986). http://dx.doi.org/10.1364/JOSAA.3.000847 JOSAAH 0030-3941 Google Scholar
D. C. Ghiglia and M. D. Pritt, Two-Dimensional Phase Unwrapping: Theory, Algorithms and Software, Wiley-Interscience, New York
(1998). Google Scholar
T. Zikmund et al.,
“Sequential processing of quantitative phase images for the study of cell behaviour in real-time digital holographic microscopy,”
J. Microsc., 256
(2), 117
–125
(2014). http://dx.doi.org/10.1111/jmi.12165 JMICAR 0022-2720 Google Scholar
M. Born and E. Wolf, Principles of Optics, 7th ed.Cambridge University Press, Cambridge
(1986). Google Scholar
E. D. Michelakis, L. Webster and J. R. Mackey,
“Dichloroacetate (DCA) as a potential metabolic-targeting therapy for cancer,”
Br. J. Cancer, 99
(7), 989
–994
(2008). http://dx.doi.org/10.1038/sj.bjc.6604554 BJCAAI 0007-0920 Google Scholar
B. M. Madhok et al.,
“Dichloroacetate induces apoptosis and cell-cycle arrest in colorectal cancer cells,”
Br. J. Cancer, 102
(12), 1746
–1752
(2010). http://dx.doi.org/10.1038/sj.bjc.6605701 BJCAAI 0007-0920 Google Scholar
K. M. Anderson et al.,
“In vitro effects of dichloroacetate and on hypoxic HeLa cells,”
Anticancer Res., 29
(11), 4579
–4588
(2009). ANTRD4 0250-7005 Google Scholar
Q. S. Chu et al.,
“A phase I open-labeled, single-arm, dose-escalation, study of dichloroacetate (DCA) in patients with advanced solid tumors,”
Invest New Drugs., 33
(3), 603
–610
(2014). http://dx.doi.org/10.1093/annonc/mdu331 ANONE2 0923-7534 Google Scholar
H. Shen et al.,
“Dual-targeting of aberrant glucose metabolism in glioblastoma,”
J. Exp. Clin. Cancer Res., 34
(14),
(2015). http://dx.doi.org/10.1186/s13046-015-0130-0 Google Scholar
BiographyJana Collakova is a PhD student at the Brno University of Technology. She received her BS degree in optics from the Palacky University in Olomouc in 2009 and MS degree in optics and precise mechanics from the Brno University of Technology in 2011. Her current research interests include digital holographic microscopy in turbid media and living cells imaging. Aneta Krizova is a PhD student at the Brno University of Technology. She received her BS and MS degrees in physical engineering from the Brno University of Technology in 2010 and 2012. Her current research interests include light microscopy, especially holographic microscopy and its applications. Vera Kollarova is a postdoctoral fellow at the Brno University of Technology. She received her BS and MS degrees in optics from the Palacky University in Olomouc in 2001 and 2003, respectively, and PhD degree in optics from same university in 2011. Her current research interests include holographic microscopy and imaging through scattering media. Zbynek Dostal is a PhD student at the Brno University of Technology. He received his BS degree in mechanical engineering in 2007 and MS degree in optics and precise mechanics in 2009 from the Brno University of Technology. He is a co-author of the CCHM patent for which he received the Werner von Siemens Excellence Award 2013. His current research interests include holographic microscopy, automation in microscopy, optical and mechanical design. Michala Slaba is a PhD student at the Brno University of Technology. She received her BS and MS degrees in physical engineering from the Brno University of Technology in 2008 and 2010. Her current research interests include wave optics, imaging theory and holographic microscopy. Pavel Vesely is a senior research scientist at the CEITEC, Brno University of Technology. He received his MD degree from the Charles University in Prague in 1961 and PhD degree in experimental biology from the Czechoslovak Academy of Sciences in 1965. He is the author of more than 100 journal papers. His lifelong research interests in cancer cell biology currently include domestication of coherence-controlled holographic microscopy in cell biology research. Radim Chmelik is a professor of applied physics at the Brno University of Technology. He received his MS degree in solid state physics from the Masaryk University in Brno in 1989, and his PhD degree in physical and materials engineering from the Brno University of Technology in 1997. He is the author of more than 40 journal papers. His current research interests include wave optics, imaging theory, advanced and 3-D light microscopy, and holographic microscopy. He is a member of SPIE and OSA. |