3 February 2017 Heating system of shutter house for the Antarctic Bright Stars Survey Telescope
Author Affiliations +
Abstract
A heating system for the mechanical shutter for the Antarctic Bright Stars Survey Telescope (BSST) is introduced. The system consists of a thermal insulation shutter house and a heating control box. The key design of the thermal-insulation shutter house is introduced. The heating control algorithm based on fuzzy-proportional–integral–derivative is designed to improve the performance of the system. A secure control algorithm for power MOSFET is necessary in extremely cold environments. The system has been tested in the cryogenic environment for 4 weeks, which proved that the heating system has the characteristics of low temperature adaption, high accuracy of the temperature control, remote operation, and detection. As a part of the BSST, the system has been running successfully for over half a year at Zhongshan Station, Antarctica.
© 2017 Society of Photo-Optical Instrumentation Engineers (SPIE)
Jie Chen, Jian Wang, Shucheng Dong, Fengxin Jiang, Minghao Jia, Hongfei Zhang, "Heating system of shutter house for the Antarctic Bright Stars Survey Telescope," Journal of Astronomical Telescopes, Instruments, and Systems 3(1), 015001 (3 February 2017). https://doi.org/10.1117/1.JATIS.3.1.015001 . Submission: Received: 24 July 2016; Accepted: 9 January 2017
Received: 24 July 2016; Accepted: 9 January 2017; Published: 3 February 2017
JOURNAL ARTICLE
7 PAGES