1 March 2007 Real-time reflectance confocal microscopy: comparison of two-dimensional images and three-dimensional image stacks for detection of cervical precancer
Author Affiliations +
J. of Biomedical Optics, 12(2), 024021 (2007). doi:10.1117/1.2717899
Abstract
(Partial Abstract) Confocal microscopy can provide real-time, 2-D and 3-D images of the cellular morphology and tissue architecture features that pathologists use to detect precancerous lesions without the need for tissue removal, sectioning, and staining. The utility of 3-D confocal image stacks of epithelial tissue for detecting dysplasia has not yet been explored. We aim to extract morphometry and tissue architecture information from 2-D confocal reflectance images and 3-D image stacks from fresh, unstained cervical biopsies and compare their potential for detecting dysplasia. Nine biopsies are obtained from eight patients; confocal images are acquired pre- and postacetic acid at multiple epithelial depths in 1.5 μm-intervals. Postacetic acid images are processed to segment cell nuclei; after segmentation, 2-D images taken at 50 μm below the tissue surface, and the entire 3-D image stacks are processed to extract morphological and architectural features. Data are analyzed to determine which features gave the best separation between normal and high-grade cervical precancer. Most significant differences are obtained from parameters extracted from the 3-D image stacks. However, in all cases where the 2-D features were multiplicatively scaled by the depth of acquisition divided by the epithelial thickness or scaled by the scattering coefficient, the significance level is equal to or greater than the comparable feature extracted from the 3-D image stacks. A linear discriminant function previously developed to separate 19 samples of normal tissue and high-grade cervical precancer based on the nuclear-to-cytoplasm (N/C) ratio and epithelial scattering coefficient is prospectively applied to the nine biopsies examined to determine the accuracy with which it could separate normal tissue from cervical intra epithelial neoplasia (CIN) 2/3. For the entire data set of 28 biopsies, a sensitivity and specificity of 100% is produced using this discriminant function;
Thomas G. Collier, Martial Guillaud, Anais Malpica, Michelle Follen, Rebecca R. Richards-Kortum, "Real-time reflectance confocal microscopy: comparison of two-dimensional images and three-dimensional image stacks for detection of cervical precancer," Journal of Biomedical Optics 12(2), 024021 (1 March 2007). http://dx.doi.org/10.1117/1.2717899
JOURNAL ARTICLE
7 PAGES


SHARE
KEYWORDS
Biopsy

3D image processing

Confocal microscopy

Image segmentation

Scattering

Tissues

Reflectivity

RELATED CONTENT


Back to Top