16 September 2013 Elastographic mapping in optical coherence tomography using an unconventional approach based on correlation stability
Author Affiliations +
J. of Biomedical Optics, 19(2), 021107 (2013). doi:10.1117/1.JBO.19.2.021107
Abstract
An approach to elastographic mapping in optical coherence tomography (OCT) using comparison of correlation stability of sequentially obtained intensity OCT images of the studied strained tissue is discussed. The basic idea is that for stiffer regions, the OCT image is distorted to a smaller degree. Consequently, cross-correlation maps obtained with compensation of trivial translational motion of the image parts using a sliding correlation window can represent the spatial distribution of the relative tissue stiffness. An important advantage of the proposed approach is that it allows one to avoid the stage of local-strain reconstruction via error-sensitive numerical differentiation of experimentally determined displacements. Another advantage is that the correlation stability (CS) approach intrinsically implies that for deformed softer tissue regions, cross-correlation should already be strongly decreased in contrast to the approaches based on initial reconstruction of displacements. This feature determines a much wider strain range of operability than the proposed approach and is favorable for its free-hand implementation using the OCT probe itself to deform the tissue. The CS approach can be implemented using either the image elements reflecting morphological structure of the tissue or performing the speckle-level cross-correlation. Examples of numerical simulations and experimental demonstrations using both phantom samples and in vivo obtained OCT images are presented.
© 2014 Society of Photo-Optical Instrumentation Engineers (SPIE)
Vladimir Yu. Zaitsev, Lev A. Matveev, Alexandr L. Matveyev, Grigory V. Gelikonov, Valentin M. Gelikonov, "Elastographic mapping in optical coherence tomography using an unconventional approach based on correlation stability," Journal of Biomedical Optics 19(2), 021107 (16 September 2013). http://dx.doi.org/10.1117/1.JBO.19.2.021107
JOURNAL ARTICLE
13 PAGES


SHARE
KEYWORDS
Optical coherence tomography

Tissues

Speckle

Image processing

Tissue optics

Image compression

In vivo imaging

RELATED CONTENT

CdS nanoparticle light-emitting diode on Si
Proceedings of SPIE (June 06 2002)
Fundamentals Of Topographic Substrate Leveling
Proceedings of SPIE (January 01 1988)
Top-down vertical itemset mining
Proceedings of SPIE (March 04 2015)
Excimer laser in art restoration
Proceedings of SPIE (May 04 1993)

Back to Top