1 January 2010 Slider-adjusted softcopy ruler for calibrated image quality assessment
Author Affiliations +
J. of Electronic Imaging, 19(1), 011009 (2010). doi:10.1117/1.3271133
ISO 20462 part 3 standardized the hardcopy quality ruler and a softcopy quality ruler based on a binary sort approach involving paired comparisons. The new softcopy ruler method described here utilizes a slider bar to match the quality of the ruler to that of the test image, which is found to substantially reduce the time required per assessment (30 to 15.5 s), with only a modest loss of precision (standard deviations of 2.5 to 2.9 just noticeable differences). In combination, these metrics implied a 20% improvement in the standard error of the mean achievable in a fixed amount of judging time. Ruler images calibrated against the standard quality scale of ISO 20462 are generated for 21 scenes, at 31 quality levels each, achieved through variation of sharpness, while other attributes are held near their preferred positions. The images are bundled with documentation and a MATLAB source code for a graphical user interface that administers softcopy ruler experiments, and these materials are donated to the International Imaging Industry Association for distribution. In conjunction with a specified large flat panel display, these materials should enable users to conduct softcopy quality ruler experiments with minimum effort, and should reduce the barriers to performing calibrated psychophysical measurements.
Elaine W. Jin, Brian W. Keelan, "Slider-adjusted softcopy ruler for calibrated image quality assessment," Journal of Electronic Imaging 19(1), 011009 (1 January 2010). https://doi.org/10.1117/1.3271133