27 November 2013 Cryogenic testing of a unimorph-type deformable mirror and theoretical material optimization
Author Affiliations +
Abstract
The testing of a lightweight unimorph-type deformable mirror (DM) for wavefront correction in cryogenic instruments is reported. The presented mirror manufactured from the titanium alloy TiAl6V4 with a piezoelectric disk actuator was cooled to 86 K and characterized for thermally induced deformation and the achievable piezoelectric stroke between room temperature and 86 K. Through a finite element analysis, we obtained a first approximation in determining the exact temperature-dependent coefficient of thermal expansion (CTE) of the piezo material PIC151. Simulations were based on dilatometer measurements of the CTE of the TiAl6V4 mirror base between room temperature and 86 K. These investigations will enable the improvement of the athermal design of a unimorph-type DM.
© 2014 Society of Photo-Optical Instrumentation Engineers (SPIE)
Matthias Goy, Matthias Goy, Claudia Reinlein, Claudia Reinlein, Jan Kinast, Jan Kinast, Nicolas Lange, Nicolas Lange, } "Cryogenic testing of a unimorph-type deformable mirror and theoretical material optimization," Journal of Micro/Nanolithography, MEMS, and MOEMS 13(1), 011107 (27 November 2013). https://doi.org/10.1117/1.JMM.13.1.011107 . Submission:
JOURNAL ARTICLE
7 PAGES


SHARE
RELATED CONTENT

A cryogenic 'set-and-forget' deformable mirror
Proceedings of SPIE (July 21 2016)
Developments of piezo deformable mirrors
Proceedings of SPIE (July 26 2016)
Design, processing, and materials for large-stroke actuators
Proceedings of SPIE (February 05 2007)
Tests of nanometer class structural actuators at 30 and 300...
Proceedings of SPIE (September 28 2004)
Ultra-Precision Linear Actuator for optical systems
Proceedings of SPIE (October 23 2000)
Athermalized embedding of actuators in cryogenic mirrors
Proceedings of SPIE (September 17 2009)

Back to Top