29 June 2017 High-precision CD measurement using energy-filtering SEM techniques
Author Affiliations +
J. of Micro/Nanolithography, MEMS, and MOEMS, 16(2), 024004 (2017). doi:10.1117/1.JMM.16.2.024004
Voltage contrast (VC) images obtained using an energy filter (EF) were used to measure the bottom surface of high-aspect-ratio structures. The VC images obtained using the conventional EF were sensitive to variations in wafer potential. Since CD-SEM metrology requires precise EF voltage control when using VC images, we developed an EF voltage correction method to be used at each measurement point. Consequently, bottom-edge measurement, independent of the wafer potential fluctuations, was achieved using the newly developed EF. Our developed technique is effective for CD-SEM metrology using VC images.
© 2017 Society of Photo-Optical Instrumentation Engineers (SPIE)
Daisuke Bizen, Makoto Sakakibara, Makoto Suzuki, Yoshinori Momonoi, Hajime Kawano, "High-precision CD measurement using energy-filtering SEM techniques," Journal of Micro/Nanolithography, MEMS, and MOEMS 16(2), 024004 (29 June 2017). https://doi.org/10.1117/1.JMM.16.2.024004 Submission: Received 5 April 2017; Accepted 12 June 2017
Submission: Received 5 April 2017; Accepted 12 June 2017


Using the analytical linescan model for SEM metrology
Proceedings of SPIE (March 28 2017)
Revisiting mask contact hole measurements
Proceedings of SPIE (October 20 2006)
Survey on pattern dimension measurement
Proceedings of SPIE (August 04 1993)