12 October 2017 Influence of a wrinkle in terms of critical dimension variation caused by transmission nonuniformity and a particle defect on extreme ultraviolet pellicle
Author Affiliations +
Abstract
An extreme ultraviolet (EUV) pellicle is needed for the protection of EUV masks from defects, contaminants, and particles during the exposure process. However, the EUV pellicle can be easily deformed during the exposure process because it has an extremely thin thickness for high transmission of EUV lights. Due to the very thin thickness and the weak structure of the pellicle, a pellicle is easily deformed; a wrinkled pellicle causes an image distortion, which leads to critical dimension (CD) variation. In addition, a particle defect on an EUV pellicle can result from scanner building materials. Added materials of the particle defect on an EUV pellicle can also cause image distortion and CD variation. We investigated the impact of wrinkles and particle defects on the transmission and CD variation for the 5- and 3-nm nodes of isomorphic and anamorphic numerical aperture (NA) systems. The variation in transmission and the critical size of the particle defect with a wrinkled EUV pellicle were calculated to obtain the requirement of a CD variation of 0.2 nm for a EUV pellicle. As a result, a change in transmission of 1.9% (after two pass) resulted in a 0.2-nm variation in the CD for the anamorphic NA system (3-nm node), whereas a transmission variation of 1.3% (after two pass) caused a 0.2-nm CD variation in the isomorphic NA system (5-nm node). From these results, an allowable local tilt angle can be calculated; the allowable local tilt angle of an isomorphic NA system is 0.31 rad and that of an anamorphic NA system is 0.41 rad. When the particle defect is added on a wrinkled EUV pellicle, the critical size of the particle defect is 1.2    μ m for the 5-nm node and 2.2    μ m for the 3-nm node.
© 2017 Society of Photo-Optical Instrumentation Engineers (SPIE)
Guk-Jin Kim, Guk-Jin Kim, In-Seon Kim, In-Seon Kim, Sung-Gyu Lee, Sung-Gyu Lee, Michael Yeung, Michael Yeung, Min-Su Kim, Min-Su Kim, Jin-Goo Park, Jin-Goo Park, Hye-Keun Oh, Hye-Keun Oh, } "Influence of a wrinkle in terms of critical dimension variation caused by transmission nonuniformity and a particle defect on extreme ultraviolet pellicle," Journal of Micro/Nanolithography, MEMS, and MOEMS 16(4), 041008 (12 October 2017). https://doi.org/10.1117/1.JMM.16.4.041008 . Submission: Received: 27 April 2017; Accepted: 21 September 2017
Received: 27 April 2017; Accepted: 21 September 2017; Published: 12 October 2017
JOURNAL ARTICLE
4 PAGES


SHARE
RELATED CONTENT

Properties and performance of EUVL pellicle membranes
Proceedings of SPIE (October 22 2015)
EUV mask infrastructure readiness and gaps for TD and HVM
Proceedings of SPIE (November 10 2015)
EUV lithography imaging using novel pellicle membranes
Proceedings of SPIE (March 17 2016)
NXE pellicle offering a EUV pellicle solution to the...
Proceedings of SPIE (March 17 2016)
NXE pellicle: development update
Proceedings of SPIE (September 25 2016)
Pattern degradation with larger particles on EUV pellicle
Proceedings of SPIE (October 08 2018)

Back to Top