Open Access
14 September 2017 Comparison of oxyhemoglobin and deoxyhemoglobin signal reliability with and without global mean removal for digit manipulation motor tasks
Swethasri Dravida, Jack Adam Noah, Xian Zhang, Joy Hirsch
Author Affiliations +
Abstract
Functional near-infrared spectroscopy (fNIRS) could be well suited for clinical use, such as measuring neural activity before and after treatment; however, reliability and specificity of fNIRS signals must be ensured so that differences can be attributed to the intervention. This study compared the test–retest and longitudinal reliability of oxyhemoglobin and deoxyhemoglobin signals before and after spatial filtering. In the test–retest experiment, 14 participants were scanned on 2 days while performing four right-handed digit-manipulation tasks. Group results revealed greater test–retest reliability for oxyhemoglobin than deoxyhemoglobin signals and greater spatial specificity for the deoxyhemoglobin signals. To further characterize reliability, a longitudinal experiment was conducted in which two participants repeated the same motor tasks for 10 days. Beta values from the two tasks with the lowest and highest test–retest reliability, respectively, in the spatially filtered deoxyhemoglobin signal are reported as representative findings. Both test–retest and longitudinal methods confirmed that task and signal type influence reliability. Oxyhemoglobin signals were more reliable overall than deoxyhemoglobin, and removal of the global mean reduced reliability of both signals. Findings are consistent with the suggestion that systemic components most prevalent in the oxyhemoglobin signal may inflate reliability relative to the deoxyhemoglobin signal, which is less influenced by systemic factors.

1.

Introduction

Functional near-infrared spectroscopy (fNIRS) is a neuroimaging technique that records changes in blood oxygen levels, which are used as a proxy for localized neural activity. Recent advances in fNIRS hardware allow for whole-brain imaging in ecologically valid contexts and have prompted a dramatic increase in fNIRS research.1 Of particular interest are longitudinal studies, including studies that focus on changes in brain activity underlying learning and training.24 fNIRS is a relatively inexpensive, radiation-free method of obtaining continuous or repeated measurements that can be used to evaluate learning, training, intervention, or neurofeedback. For these applications, it is necessary to understand the reliability of the NIRS signal with respect to changes in oxyhemoglobin (OxyHb), deoxyhemoglobin (deOxyHb), and systemic effects, particularly when signal changes may reflect either the outcome of a treatment or signal attenuation.

Reliability is defined as the reproducibility of a measurement.5 Variation in the reliability of neural recordings can come from many sources, including equipment, signal-to-noise ratio, and participant variability. Test–retest reliability is an indicator of consistency in repeated measurements made with one particular method or tool.6 A number of reports have previously investigated test–retest reliability using fNIRS. Some of these reports compared reliability in blood oxygen saturation across devices.7 In one study, Yoshitani et al. showed that the type of NIRS machine and the methodology used to obtain signals can influence the measures of blood oxygen saturation (SO2) differentially in the presence of changing CO2 concentration in the blood. A number of methodological issues were reported for discrepancies, including how blood saturation was measured by each machine, the influence of extracranial blood flow on both measures, and the source of light used for measurements (laser diode versus LED). Reliability in tissue saturation in infants8 has also been investigated. This study reported test–retest and inter-rater reliability for changes in hemoglobin measures as well as oxygen saturation using NIRS on infants during resting state. The results showed that SO2 measures were reliable both day to day as well as between raters, but significant differences in hemodynamic measures were found between baseline measures and across raters. Errors in placement of the single measurement channel were one potential source of error suggested by the authors. Functional NIRS has also been evaluated for reliability with respect to its use in cognitive screening.9 This study showed mixed results for the reliability of OxyHb and deOxyHb in multiple areas of the frontal lobe but suggested OxyHb may be more reliable for some types of cognitive tasks. Visual and auditory stimulation,10 as well as motor output tasks,11 have also been tested for reliability. In the 2006 paper, the authors showed that OxyHb signals during a passive visual viewing task were more reliable than deOxyHb. In their 2007 study, they found that deOxyHb showed more localized responses in a finger-thumb tapping task, but reliability was low for both oxy and deOxyHb signals. The authors suggest that differences in probe placement may have contributed to some of the variability. While there is general agreement about basic mechanisms of action relating to tissue saturation and changes in hemoglobin concentration during functional activity, the relative reliability of OxyHb and deOxyHb remains an active area of research. The goal of this experiment was to build on what has been previously reported and evaluate the effects of global mean removal on the reliability of OxyHb and deOxyHb signals.

Functional NIRS records changes in oxyhemoglobin and deoxyhemoglobin concentrations. The specific changes in hemodynamic signals recorded with fNIRS reflect underlying neural activity but may also contain multiple sources of systemic effects.1214 Two techniques are commonly used for removing systemic components from fNIRS signals. The first is short channel separation, which has been shown to be able to remove a localized artifact that is non-hemodynamic in its temporal activation profile; however, removal of artifacts that are very similar in temporal response to neural activity, such as changes in blood pressure,15 may also regress out true neural responses. The second technique is a principle components analysis (PCA) spatial filter14 that removes activity distributed across the entire cortex, which has been shown to be effective in isolating neural responses. We evaluate this spatial filter to determine how systemic components affect the reliability of fNIRS recordings.

Here, we investigate the effects of signal and task type on the reliability of fNIRS data. The overall goal of this study was to compare the reliability of fNIRS signals in the motor cortex in a test–retest experiment. Specifically, we obtained whole-head fNIRS recordings during a series of digit manipulation tasks in which participants perform stress ball squeezing, finger-thumb tapping, double finger-thumb tapping, and a finger-thumb tapping task in which participants tapped specific digits against their thumb when cued by a number. Expected responses in the contralateral motor cortex were observed for all tasks across participants on day one and day two. We compared reliability from day one to day two in OxyHb and deOxyHb signals in all tasks both before and after spatial filtering of systemic components. We specifically assessed whether OxyHb or deOxyHb was a more reliable signal for each of the four motor tasks. Finally, we determined how the OxyHb and deOxyHb signals varied in a longitudinal experiment in which two participants repeated the same four motor tasks for 10 days.

2.

Test–Retest Experiment Methods

2.1.

Participants

Fourteen participants (4 male, 10 female; mean age: 26.9+/9.5 years; 100% right-handed 16) took part in the experiment over 2 days. Participants provided written informed consent in accordance with guidelines approved by the Yale University Human Investigation Committee (HIC #1501015178). All data were obtained at the Yale School of Medicine, New Haven, Connecticut. Each person was compensated for participation in the study.

2.2.

Paradigm

In the test–retest experiments, participants completed four tasks that required right-handed digit manipulation. For the first task (“ball squeeze”), participants squeezed an elastic stress ball in response to cues presented on a computer screen. During the second task (“double finger tap”), participants tapped each finger sequentially against the thumb twice per cue. For the third run (“finger tap”), participants tapped each finger sequentially against the thumb once per cue. During the fourth run (“follow the number”), a number from 1 through 4 appeared randomly on the screen. Participants were instructed to tap the first finger against the thumb in response to “1,” the middle finger in response to “2,” the ring finger in response to “3,” and the pinky finger in response to “4.” Each run consisted of six blocks. Each block consisted of 20 s of task followed by 10 s of rest, during which participants were instructed to focus on a crosshair on the screen and keep their hands still. There were 24 cues presented every 0.83 s during the 20-s task block.

2.3.

Signal Acquisition

Data were acquired using a multichannel, continuous wave Shimadzu LABNIRS system (LABNIRS, Shimadzu Corp., Kyoto, Japan), which consists of emitters that connect to laser diodes at three wavelengths (780, 805, and 830 nm). Each participant was fitted with an optode cap with predefined distances of 2.75 or 3 cm depending on the size of the individual’s head. The cap was placed so that the most anterior optode-holder was positioned 1  cm above nasion and the most posterior opode holder 1 cm below inion. These anatomical landmarks were chosen to maximize the chance that the cap was placed on a single participant’s head the same way each day. Hair was removed from the channel area prior to placement of each optode using a lighted fiber optic probe (Daiso, Hiroshima, Japan). Thirty-two emitters and detectors were arranged in a 105-channel layout covering the full head [Fig. 1(a)]. The resistance in each channel was measured prior to recording and adjustments were made until the channel resistance met the minimum LABNIRS requirements.4,17,18 Signals were down-sampled 10-fold during the analysis for an effective sample rate of 1.0 s.

Fig. 1

Channel layouts. (a) For the test–retest experiment, 32 detectors and emitters were arranged in a 105 channel layout, represented by the blue circles. This layout covered the frontal, temporal, parietal, and occipital lobes. Black ovals surround 29 channels used for the ROI. (b) For the longitudinal experiment, 32 detectors and 29 emitters were arranged in a 98 channel layout. Black ovals surround 23 channels used for the ROI.

NPH_5_1_011006_f001.png

2.4.

Optode Localization

Following signal acquisition, the optodes were removed from the cap, but the cap was left on the participant for the purpose of optode localization. Anatomical locations of optodes with respect to the standard 10 to 20 system19 head landmarks nasion, inion, Cz, T3 (left tragus), and T4 (right tragus) were determined using a Patriot 3-D Digitizer (Polhemus, Colchester, Vermont) and previously described linear transform techniques.2023 The NIRS-SPM software24 was used with MATLAB (Mathworks, Natick, Massachusetts) to determine Montreal Neurological Institute (MNI) coordinates for each channel. The corresponding anatomical locations for each channel were determined using the Talairach atlas.25,26

2.5.

Signal Processing

A modified Beer–Lambert equation was used to convert raw fNIRS data to deoxyhemoglobin and oxyhemoglobin concentrations, and wavelet detrending was applied to these values. A fourth-degree polynomial was used to model and remove the baseline drift from the raw signal. For each participant, channels were automatically removed from the analysis if the root mean square of the raw data trace was 10 times that of the average for that participant. Comparisons between “clean” and “raw” data refer to data that did or did not undergo global mean removal, respectively. To generate the “clean” data, global systemic effects were removed using a spatial filter14 prior to hemodynamic modeling. The assumption underlying the use of a spatial filter is that neural activity due to the task, in this case related to finger movements, would result in activity localized to the contralateral motor cortex. Therefore, any activity present across a larger area of the brain is most likely due to global systemic effects. The algorithm used here14 utilizes PCA and a high-pass Gaussian spatial filter to remove components of the data that are present throughout the brain. Raw and clean data were reshaped into 4×4×4×133 images, and SPM8 was used for first-level general linear model (GLM) analysis.

2.6.

Contrast Comparisons

The GLM for fNIRS was used to generate contrast comparisons for each task versus rest.27 The 30-s experimental blocks, which included the 20-s task blocks and 10 s of rest, were convolved with the hemodynamic response function and modeled to fit the data. This resulted in individual beta values for each participant for every task. Beta values were obtained for all channels. One-tailed t-tests were used to generate group-level data in SPM8. Results were rendered at a threshold of p<0.005.

2.7.

Test–Retest Reliability

To evaluate the reliability of activity in the motor cortex from day 1 to day 2, each participant’s channel locations were converted to MNI space. Each participant’s data were then registered to the median channel location of both days using a nonlinear interpolation method. Once in normalized space, registered beta values were used to calculate test–retest reliability over 2 days. Beta values in all channels from all four tasks from both days were averaged, and the channel with the maximum beta value in a preidentified region of interest (ROI) was identified for each participant [black ovals in Fig. 1(a)]. The ROI comprised 29 channels in the left hemisphere, covering premotor, primary-motor, and supplementary motor areas. The channel with the maximum average beta value, the channel of interest, differed across participants. Once the channel of interest was identified, beta values in that channel were extracted for each task from both days for each participant. The intraclass correlation coefficient (ICC) was used to compare the degree of reliability between the beta values on day 1 versus day 2. A MATLAB script was used to generate the ICCs for each signal type (deOxyHb and OxyHb) and each processing type (raw and clean) for each digit manipulation task.

2.8.

Similarity of Day-to-Day Cap Placement

The reliability of the cap placement from day to day was confirmed by taking the channel of interest for each participant and calculating the distance between the MNI coordinates for this channel on day 1 and the MNI coordinates for the same channel on day 2. The average distance between the channel of interest on day 1 and day 2 was 9.5±6.7  mm, confirming that variations in cap placements on both days were within the spatial resolution of 3 cm.

In this study, the single channel with the maximum beta value in the ROI was used to identify beta values as the measure of reliability because data from a single channel reflect the most specific local neural activity from each participant. This was intended to eliminate variability in the group location of activity due to variation in head shape across individuals. Variations in the location of the channel of interest for a single subject between day 1 and day 2 were within the spatial resolution of a single channel and, therefore, contributions to measures of reliability were not detectable. Within an individual subject, neural activity related to the task was restricted to a few channels in the primary motor or premotor/supplementary motor cortex with peak activity in one. Only in the group results, when the data were interpolated across subjects, did the combined activity cover a larger area of cortex. Using an average of the beta values in the entire area in a single individual would have therefore resulted in averaging “zeros” from channels with no significant activity, reducing the chance of comparing real activity from day to day.

3.

Test–Retest Results

3.1.

Contrast Results

The group-level results for all combined tasks versus the rest in the test–retest experiment are shown in Fig. 2 and areas in the left motor regions are reported in the tables in the Appendix. The results of the group-level contrast from each individual task are also shown in the Appendix. As predicted, each of the right-handed digit manipulation tasks resulted in activity in the left premotor, primary motor, and supplementary motor cortices. Results are presented for raw and clean data (Fig. 2, columns) for each signal type (OxyHb and deOxyHb, Fig. 2, rows). Consistent with prior studies,1315 raw OxyHb data showed a distributed pattern of activity that became localized when the spatial filter was used, while deOxyHb signals were localized to motor cortex for both raw and clean results.

Fig. 2

Results of all tasks contrast, p<0.005. The top row represents the group-averaged deOxyHb data; bottom row represents OxyHb data. (a) Results of raw deOxyHb data from day 1 and day 2. (b) Results of clean (spatial filter applied) deOxyHb data from day 1 and day 2. (c) Results of raw OxyHb data from day 1 and day 2. (d) Results of clean (spatial filter applied) OxyHb data from day 1 and day 2.

NPH_5_1_011006_f002.png

3.2.

Test–Retest Signal Reliability

ICCs were used as a measure of test–retest signal reliability. The ICC values were determined for each task and both types of signal: deOxyHb versus OxyHb with and without global mean removal. The overall ICC value for each signal type was also calculated using the beta values from all tasks from both days. The ICCs are shown in Table 1. When collapsed across raw and clean data, the ICC values for the four tasks obtained from the OxyHb signal were significantly greater than those obtained from the deOxyHb signal (one-tailed paired t-test, p=0.048). When collapsed across OxyHb and deOxyHb data, the ICC values for the four tasks using the raw data were significantly greater than the ICC values for the clean data (one-tailed paired t-test, p=0.0086).

Table 1

Test–retest ICC for each task and for the combination of all tasks.

DeoxyHbOxyHb
RawCleanRawClean
Ball squeeze0.59060.38510.81940.7086
Double tap0.59220.45390.84630.8307
Single tap0.68150.56870.73740.5142
Follow the number0.65800.67220.58780.5843
All tasks0.61880.50200.76590.6588

4.

Longitudinal Experiment

We compared the amount of systemic component versus neural signals in these tasks by conducting a second experiment (referred to as the longitudinal experiment) in which two participants performed the same four tasks every day for 10 days. The basis for this experiment was the expectation that when a participant undergoes the same task every day, neural signals will attenuate over time due to a repetition effect.2830 The hypothesis for this experiment was twofold. First, we predicted that tasks that generate more systemic artifacts would show less attenuation in the OxyHb data over the course of the 10 days than tasks that generate fewer artifacts. Second, we hypothesized that deOxyHb data would show similar attenuation in all tasks, as this signal is less affected by systemic artifacts.12,14,15

5.

Longitudinal Experiment Methods

5.1.

Participants

Two right-handed participants (one 25-year-old female and one 42-year-old male) participated in the longitudinal experiment and were tested for 10 days. As above, participants provided written informed consent in accordance with guidelines approved by the Yale University Human Investigation Committee (HIC #1501015178), and all data were obtained at the Yale School of Medicine, New Haven, Connecticut.

The task paradigms, signal acquisition, and signal processing methods used were the same as in the test–retest experiment (see Secs. 2.22.6 above). For this experiment, 32 emitters and 29 detectors were arranged in a 98-channel layout [Fig. 1(b)], as coverage of the occipital lobe was deemed unnecessary. The ROI consisted of 23 channels in the left hemisphere [black ovals in Fig. 1(b)].

5.2.

Intraparticipant Signal Consistency

The same channel registration method described in the first experiment was used to register the data from all 10 days to one set of channel locations for each participant. To evaluate interscan variability, registered beta values from each channel were averaged over 10 days for each participant. The channel with the maximum average beta value in the left motor cortex ROI was identified for each participant, and beta values in this channel were identified for every task performed over 10 days for each participant using raw and clean signal data. As with the test–retest experiment, the channel of interest was selected for each participant. Main effects from the ball squeeze and follow the number tasks are shown below. These two tasks were chosen because they showed the greatest difference in test–retest reliability in the clean, deOxyHb signal. Out of the four tasks, the ball squeeze task showed the lowest reliability (ICC=0.3567) and the follow-the-number task showed the highest reliability (ICC=0.6264) using the deOxyHb signal with the spatial filter, which was consistent with the least amount of systemic artifact. We compared the longitudinal beta values using the deOxyHb and OxyHb signals with and without the spatial filter from both of these tasks for each participant over the course of 10 days.

5.3.

Regression Slope Tests

The beta values in the channel of interest were plotted over the 10 days for each participant in each task. A trend line was fitted to the data, and a regression slope test was performed on each trend line, to evaluate whether the slope was significantly different from zero. In a regression slope test, a t statistic is obtained by dividing the slope of the line by the standard error of the slope. This t statistic was then converted to a p value using the degrees of freedom (number of points -2). A p value less than 0.05 was considered to be significant, namely that the slope of the trend line over the 10 days was significantly different from zero.

6.

Longitudinal Experiment Results

Both participants completed the four tasks of experiment 1 every day for 10 days. Here, we compare the results from the ball squeeze task and the follow the number task using the OxyHb and deOxyHb signals, with and without the spatial filter. The graphs in Fig. 3 show the beta values and trend lines for each signal type over the course of the 10 days for participants 1 and 2. Red points and lines represent data using the OxyHb signal and blue points and lines represent the deOxyHb signal. Triangular points and darker colors represent raw data and circular points and lighter colors represent clean (spatially filtered) data. We refer to “attenuation” over the 10 days if the slope of the line was negative and significantly different from zero (p<0.05). Slopes of each trend line are shown in Table 2. For subject 1, no signal showed attenuation over the 10 days during the ball squeeze task; although, the clean deOxyHb signals showed a negative trend (p=0.067). In the follow-the-number task, however, all signals showed attenuation (p<0.05) except the raw deOxyHb signal, which showed a trend (p=0.084). For subject 2, no signals showed attenuation, either in the ball squeeze or the follow-the-number task.

Fig. 3

Results of 10-day longitudinal study. Top row represents data from participant 1; bottom row represents data from participant 2. Left column shows result of the ball squeeze task; right column shows result of the follow the number task. Daily beta values and trend lines are shown. Red represents OxyHb; blue represents deOxyHb. Dark colors and triangles represent raw data; lighter colors and circles represent clean data.

NPH_5_1_011006_f003.png

Table 2

Slopes of functions in Fig. 3. Asterisks (*) indicate significance (p<0.05); (−) indicates negative slope.

DeOxyHbOxyHb
RawCleanRawClean
Subject 1Ball squeeze5.878.371.363.09
Follow the number6.5811.27*13.00*9.70*
Subject 2Ball squeeze0.413.933.986.31
Follow the number8.313.9713.379.44

7.

Discussion

To study the test–retest reliability of fNIRS signals, we asked participants to perform four different motor tasks on two separate days. Overall, the OxyHb signal was shown to be more reliable than the deOxyHb signal, and the reliability was also higher for the raw signal than for signals that had undergone a spatial filter. To test the extent to which these signals were stable over time, a longitudinal study was conducted in which two participants performed the same four motor tasks for 10 days. A comparison of two representative tasks with the highest and lowest test–retest reliability in the clean deOxyHb signals (follow the number and ball squeeze, respectively) showed that these tasks elicit different levels of neural and global components in some participants. For the “ball squeeze” task, which had the lowest test–retest reliability using the clean deOxyHb data, neither participant showed attenuation in any signal, OxyHb or deOxyHb, with or without the spatial filter over the course of the 10 days. However, for the “follow the number” task, which showed the highest test–retest reliability in the clean deOxyHb signal, in one participant, signals showed attenuation over 10 days, indicating that this task may elicit less systemic noise in some subjects. This study is the first to our knowledge to systematically analyze the reliability of OxyHb and deOxyHb signals with and without a spatial filter, and our findings suggest that systemic components present in fNIRS signals may be individually specific and inflate day-to-day reliability relative to the underlying neural components. Further, the global mean may inform physiological processes associated with specific functional tasks and neural mechanisms, adding insight to our understanding of neurovascular interactions.

Prior studies have shown that the OxyHb signal is more susceptible to systemic artifacts than the deOxyHb signal12,14,15 and our results additionally indicate that the OxyHb signal is more reliable than the deOxyHb signal. One interpretation suggests that systemic effects are more similar day to day than neural effects. Reduced reliability for the clean signals relative to the raw signals also supports this interpretation. This reliability, however, comes at the cost of functional specificity, as the activity represented by the raw OxyHb signal was widely distributed rather than limited to left motor cortex and adjacent areas. Applying a spatial filter to these results improved the functional specificity but still showed higher reliability values when compared to the deOxyHb signal, which is known to be less susceptible to systemic effects.

The group findings also support the conclusion that the deOxyHb signal, while less reliable, was less affected by systemic components than OxyHb, suggested by the more localized region of activity in Fig. 2. The reduced reliability observed for the deOxyHb signal, assumed to be primarily neural in origin, raises important questions about the nature of the interaction between systemic and neural effects between tasks and across days, and about strategies to improve signal acquisition and processing.

For the Ball squeeze task in the longitudinal experiment, the beta values for the OxyHb were higher than for the deOxyHb throughout the 10 days for all tasks in both subjects. Even when the spatial filter was applied to the OxyHb signals, the beta values remained high in both participants without evidence of attenuation. Similarly, the deOxyHb signal did not show significant attenuation for either participant during this task, even after application of the spatial filter. One interpretation of this result is that both signals obtained during this task were more influenced by systemic components. This is consistent with the group results for this task, which show widespread, non-specific activation in both hemispheres in the raw, OxyHb signals (see Appendix, Fig. 4). It is possible that the global components in the signals elicited by this task masked any putative signal attenuation over the course of the 10 days.

Fig. 4

Results of ball squeeze task, p<0.005. The top row represents the group-averaged deOxyHb data; bottom row represents OxyHb data. (a) Results of raw deOxyHb data from day 1 and day 2. (b) Results of clean (spatial filter applied) deOxyHb data from day 1 and day 2. (c) Results of raw OxyHb data from day 1 and day 2. (d) Results of clean (spatial filter applied) OxyHb data from day 1 and day 2.

NPH_5_1_011006_f004.png

By contrast, the task with the highest reliability in the test–retest experiment using the clean, deOxyHb signal was follow the number, which had a cognitive component that the other tasks did not. For the follow the number task, participants were asked to move a specific finger in response to the numbered cue, requiring increased attention to execute an unpredictable sequence of finger movements. In the test–retest experiment, this task showed low reliability in the OxyHb signals, but higher reliability in the deOxyHb and especially in the clean data. This is consistent with the hypothesis that global components in the data lead to higher reliability, and this task may either elicit less systemic artifacts or the global components may be more effectively separated from neural signals in this task using our method of global mean removal. In the longitudinal experiment, for one participant, this task showed attenuation over 10 days in all signal types, supporting the hypothesis that it may not elicit as much global signal as the ball squeeze task for this subject. However, this attenuation was not present in the data from the second participant, showing that this effect was variable across participants. While the global systemic artifact increases the reliability of the data, using a task that elicits a less global signal may result in signals that are more likely to be neural in origin. However, further studies that directly record systemic measures are necessary to determine what, if any, task features cause increases or decreases in the systemic artifact accompanying neural signals.

Findings of this study suggest that day-to-day reliability of fNIRS recordings depends on both the signal and task used and that reliability may be inflated by systemic factors rather than neural activity. In general, neural and systemic components differentially affect OxyHb and deOxyHb signals. The deOxyHb signal was less reliable but the task-based effect was spatially specific. These factors are especially important in the design of pre/postintervention experiments as they influence the likelihood that changes in signals reflect neural effects of the treatment or intervention.

Fig. 5

Results of double tap task, p<0.005. The top row represents the group-averaged deOxyHb data; bottom row represents OxyHb data. (a) Results of raw deOxyHb data from day 1 and day 2. (b) Results of clean (spatial filter applied) deOxyHb data from day 1 and day 2. (c) Results of raw OxyHb data from day 1 and day 2. (d) Results of clean (spatial filter applied) OxyHb data from day 1 and day 2.

NPH_5_1_011006_f005.png

Fig. 6

Results of single tap task, p<0.005. The top row represents the group-averaged deOxyHb data; bottom row represents OxyHb data. (a) Results of raw deOxyHb data from day 1 and day 2. (b) Results of clean (spatial filter applied) deOxyHb data from day 1 and day 2. (c) Results of raw OxyHb data from day 1 and day 2. (d) Results of clean (spatial filter applied) OxyHb data from day 1 and day 2.

NPH_5_1_011006_f006.png

Appendices

Appendix:

Group-level Task Contrast Results

Group-level results from each of the motor tasks in the test–retest experiment are shown below (Figs. 47). Areas in the left motor cortex from each contrast are listed in Table 3 (day one) and Table 4 (day two).

Fig. 7

Results of follow the number task, p<0.005. The top row represents the group-averaged deOxyHb data; bottom row represents OxyHb data. (a) Results of raw deOxyHb data from day 1 and day 2. (b) Results of clean (spatial filter applied) deOxyHb data from day 1 and day 2. (c) Results of raw OxyHb data from day 1 and day 2. (d) Results of clean (spatial filter applied) OxyHb data from day 1 and day 2.

NPH_5_1_011006_f007.png

Table 3

Group-level GLM results from day one. Clusters of positive activity in the motor cortex and surrounding areas are listed. Horizontal lines separate results from each contrast (in bold). (−) on the x axis indicates left side. BA = Brodmann’s area. MNI coordinates were converted to Talairach coordinates to generate cluster labels.

SignalPeak MNI coordinatesPeak TP# voxelsBAAnatomical areaProbability
Ball squeeze task
OxyHb, Raw4818 626.400.00001191433Primary somatosensory cortex0.31
6Premotor and supplementary motor cortex0.29
1Primary somatosensory cortex0.15
2Primary somatosensory cortex0.13
4Primary motor cortex0.10
OxyHb, clean428 646.660.000008046Premotor and supplementary motor cortex0.79
3Primary somatosensory cortex0.12
DeOxyHb, raw4424 663.960.000632023Primary somatosensory cortex0.27
6Premotor and supplementary motor cortex0.25
1Primary somatosensory cortex0.16
2Primary somatosensory cortex0.15
4Primary motor cortex0.13
DeOxyHb, clean446 624.650.000163646Premotor and supplementary motor cortex0.80
3Primary somatosensory cortex0.11
Double tap task
OxyHb, raw4022 684.870.0001048026Premotor and supplementary motor cortex0.40
3Primary somatosensory cortex0.25
4Primary motor cortex0.17
1Primary somatosensory cortex0.12
OxyHb, clean404 644.260.000346986Premotor and supplementary motor cortex0.92
DeOxyHb, raw3814 625.430.0000418116Premotor and supplementary motor cortex0.71
3Primary somatosensory cortex0.19
DeOxyHb, clean4420 646.890.0000020056Premotor and supplementary motor cortex0.35
3Primary somatosensory cortex0.28
1Primary somatosensory cortex0.16
4Primary motor cortex0.11
Single tap task
OxyHb, raw2622 704.930.0000945366Premotor and supplementary motor cortex0.58
4Primary motor cortex0.27
3Primary somatosensory cortex0.14
OxyHb, clean4410 604.500.000217056Premotor and supplementary motor cortex0.67
3Primary somatosensory cortex0.21
DeOxyHb, Raw5010 564.200.000386616Premotor and supplementary motor cortex0.58
3Primary somatosensory cortex0.21
DeOxyHb, clean4418 544.860.0001011023Primary somatosensory cortex0.36
6Premotor and supplementary motor cortex0.25
1Primary somatosensory cortex0.19
4Primary motor cortex0.13
Follow the number task
OxyHb, raw448 626.330.0000154296Premotor and supplementary motor cortex0.74
3Primary somatosensory cortex0.16
OxyHb, clean564 485.340.000047346Premotor and supplementary motor cortex0.79
DeOxyHb, raw468 605.440.000038466Premotor and supplementary motor cortex0.70
3Primary somatosensory cortex0.20
DeOxyHb, clean468 605.760.000029116Premotor and supplementary motor cortex0.70
3Primary somatosensory cortex0.20
All tasks
OxyHb, raw4820 626.430.00001142793Primary somatosensory cortex0.31
6Premotor and supplementary motor cortex0.23
1Primary somatosensory cortex0.18
2Primary somatosensory cortex0.16
OxyHb, clean428 645.890.000019476Premotor and supplementary motor cortex0.79
3Primary somatosensory cortex0.12
DeOxyHb, raw4610 604.980.0000813756Premotor and supplementary motor cortex0.62
3Primary somatosensory cortex0.22
4Primary motor cortex0.10
DeOxyHb, clean326 666.260.0000115716Premotor and supplementary motor cortex1.00

Table 4

Group-level GLM results from day two. Clusters of positive activity in the motor cortex and surrounding areas are listed. Horizontal lines separate results from each contrast (in bold). (−) on the x axis indicates left side. BA = Brodmann’s area. MNI coordinates were converted to Talairach coordinates to generate cluster labels.

SignalPeak MNI coordinatesPeak TP# VoxelsBAAnatomical areaProbability
Ball squeeze task
OxyHb, raw34 42 706.690.00000310625Somatosensory association cortex0.35
2Primary somatosensory cortex0.19
3Primary somatosensory cortex0.16
7Somatosensory association cortex0.15
OxyHb, clean42 2 483.200.00296616Premotor and supplementary motor cortex0.88
8Includes frontal eye fields0.12
DeOxyHb, raw5022 603.870.000752063Primary somatosensory cortex0.31
2Primary somatosensory cortex0.21
1Primary somatosensory cortex0.19
6Premotor and supplementary motor cortex0.11
DeOxyHb, clean5222 584.080.000491893Primary somatosensory cortex0.31
2Primary somatosensory cortex0.22
1Primary somatosensory cortex0.17
40Supramarginal gyrus part of Wernicke’s area0.11
Double tap task
OxyHb, raw6020 484.730.0001326046Premotor and supplementary motor cortex0.24
2Primary somatosensory cortex0.23
3Primary somatosensory cortex0.19
1Primary somatosensory cortex0.17
40Supramarginal gyrus part of Wernicke’s area0.11
OxyHb, clean5412 524.740.000134856Premotor and supplementary motor cortex0.52
3Primary somatosensory cortex0.19
4Primary motor cortex0.12
DeOxyHb, raw4020 684.030.000555486Premotor and supplementary motor cortex0.48
3Primary somatosensory cortex0.24
4Primary motor cortex0.16
1Primary somatosensory cortex0.10
DeOxyHb, clean4020 684.370.000287866Premotor and supplementary motor cortex0.48
3Primary somatosensory cortex0.24
4Primary motor cortex0.16
1Primary somatosensory cortex0.10
Single tap task
OxyHb, raw5016 584.510.0002175216Premotor and supplementary motor cortex0.33
3Primary somatosensory cortex0.28
2Primary somatosensory cortex0.14
1Primary somatosensory cortex0.14
4Primary motor cortex0.10
OxyHb, clean5214 564.870.000102806Premotor and supplementary motor cortex0.42
3Primary somatosensory cortex0.22
1Primary somatosensory cortex0.13
2Primary somatosensory cortex0.12
4Primary motor cortex0.11
DeOxyHb, raw6014 464.210.000384406Premotor and supplementary motor cortex0.48
3Primary somatosensory cortex0.19
1Primary somatosensory cortex0.15
2Primary somatosensory cortex0.11
DeOxyHb, clean6014 464.630.000166056Premotor and supplementary motor cortex0.48
3Primary somatosensory cortex0.19
1Primary somatosensory cortex0.15
2Primary somatosensory cortex0.11
Follow the number task
OxyHb, raw4414 646.620.0000038706Premotor and supplementary motor cortex0.56
3Primary somatosensory cortex0.27
OxyHb, clean2410 744.950.000096436Premotor and supplementary motor cortex0.98
DeOxyHb, raw6420 344.910.00009130640Supramarginal gyrus part of Wernicke’s area0.26
6Premotor and supplementary motor cortex0.23
2Primary somatosensory cortex0.16
1Primary somatosensory cortex0.14
DeOxyHb, Clean6416 324.880.000106436Premotor and supplementary motor cortex0.31
2Primary somatosensory cortex0.14
40Supramarginal gyrus part of Wernicke’s area0.14
43Subcentral area0.13
1Primary somatosensory cortex0.11
All tasks
OxyHb, raw4632 546.710.000001965040Supramarginal gyrus part of Wernicke’s area0.45
2Primary somatosensory cortex0.27
1Primary somatosensory cortex0.18
OxyHb, clean5214 564.750.000134806Premotor and supplementary motor cortex0.42
3Primary somatosensory cortex0.22
1Primary somatosensory cortex0.13
2Primary somatosensory cortex0.12
4Primary motor cortex0.11
DeOxyHb, Raw6014 463.870.000759116Premotor and supplementary motor cortex0.48
3Primary somatosensory cortex0.19
1Primary somatosensory cortex0.15
2Primary somatosensory cortex0.11
DeOxyHb, clean6014 464.050.000528836Premotor and supplementary motor cortex0.48
3Primary somatosensory cortex0.19
1Primary somatosensory cortex0.15
2Primary somatosensory cortex0.11

Disclosures

This work was partially supported by NIH Medical Scientist Training Program Training Grant T32GM007205. The work also received partial supported by the National Institute of Mental Health of the National Institutes of Health under award number R01MH107513 (PI JH). The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health. Authors report no conflict of interest. The data reported in this paper are available upon request.

Acknowledgments

The authors thank Jenny Park and Pawan Lapborisuth for assistance with data collection.

References

1. 

D. A. Boas et al., “Twenty years of functional near-infrared spectroscopy: introduction for the special issue,” NeuroImage, 85 (Part 1), 1 –5 (2014). http://dx.doi.org/10.1016/j.neuroimage.2013.11.033 Google Scholar

2. 

D. Leff et al., “Comparing prefrontal responses evoked by a visuomotor task and a cognitive problem solving task: a longitudinal fNIRS evaluation in surgical trainees,” NeuroImage, 47 S190 (2009). http://dx.doi.org/10.1016/S1053-8119(09)72127-5 NEIMEF 1053-8119 Google Scholar

3. 

S. Koike et al., “Association between rostral prefrontal cortical activity and functional outcome in first-episode psychosis: a longitudinal functional near-infrared spectroscopy study,” Schizophr. Res., 170 (2–3), 304 –310 (2016). http://dx.doi.org/10.1016/j.schres.2016.01.003 SCRSEH 0920-9964 Google Scholar

4. 

Y. Ono et al., “Frontotemporal oxyhemoglobin dynamics predict performance accuracy of dance simulation gameplay: temporal characteristics of top-down and bottom-up cortical activities,” NeuroImage, 85 461 –470 (2014). http://dx.doi.org/10.1016/j.neuroimage.2013.05.071 NEIMEF 1053-8119 Google Scholar

5. 

L. G. Portney and M. P. Watkins, Foundations of Clinical Research: Applications to Practice, Prentice Hall, Upper Saddle River, New Jersey (2000). Google Scholar

6. 

J. P. Weir, “Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM,” J. Strength Cond. Res., 19 (1), 231 –240 (2005). Google Scholar

7. 

K. Yoshitani et al., “A comparison of the INVOS 4100 and the NIRO 300 near-infrared spectrophotometers,” Anesth. Analg., 94 (3), 586 –590 (2002). http://dx.doi.org/10.1097/00000539-200203000-00020 Google Scholar

8. 

J. Menke et al., “Reproducibility of cerebral near infrared spectroscopy in neonates,” Biol. Neonate, 83 (1), 6 –11 (2003). http://dx.doi.org/10.1159/000067006 Google Scholar

9. 

A. Watanabe et al., “Cerebrovascular response to cognitive tasks and hyperventilation measured by multi-channel near-infrared spectroscopy,” J. Neuropsychiatry Clin. Neurosci., 15 (4), 442 –449 (2003). http://dx.doi.org/10.1176/jnp.15.4.442 Google Scholar

10. 

M. M. Plichta et al., “Event-related functional near-infrared spectroscopy (fNIRS): are the measurements reliable?,” NeuroImage, 31 (1), 116 –124 (2006). http://dx.doi.org/10.1016/j.neuroimage.2005.12.008 NEIMEF 1053-8119 Google Scholar

11. 

M. Plichta et al., “Event‐related functional near‐infrared spectroscopy (fNIRS) based on craniocerebral correlations: reproducibility of activation?,” Hum. Brain Mapp., 28 (8), 733 –741 (2007). http://dx.doi.org/10.1002/(ISSN)1097-0193 Google Scholar

12. 

I. Tachtsidis and F. Scholkmann, “False positives and false negatives in functional near-infrared spectroscopy: issues, challenges, and the way forward,” Neurophotonics, 3 (3), 030401 (2016). http://dx.doi.org/10.1117/1.NPh.3.3.030401 Google Scholar

13. 

G. Strangman et al., “A quantitative comparison of simultaneous BOLD fMRI and NIRS recordings during functional brain activation,” NeuroImage, 17 (2), 719 –731 (2002). http://dx.doi.org/10.1006/nimg.2002.1227 NEIMEF 1053-8119 Google Scholar

14. 

X. Zhang, J. A. Noah and J. Hirsch, “Separation of the global and local components in functional near-infrared spectroscopy signals using principal component spatial filtering,” Neurophotonics, 3 (1), 015004 (2016). http://dx.doi.org/10.1117/1.NPh.3.1.015004 Google Scholar

15. 

E. Kirilina et al., “The physiological origin of task-evoked systemic artefacts in functional near infrared spectroscopy,” NeuroImage, 61 (1), 70 –81 (2012). http://dx.doi.org/10.1016/j.neuroimage.2012.02.074 NEIMEF 1053-8119 Google Scholar

16. 

R. C. Oldfield, “The assessment and analysis of handedness: the Edinburgh inventory,” Neuropsychologia, 9 (1), 97 –113 (1971). http://dx.doi.org/10.1016/0028-3932(71)90067-4 NUPSA6 0028-3932 Google Scholar

17. 

J. A. Noah et al., “fMRI validation of fNIRS measurements during a naturalistic task,” J. Visualized Exp., 100 e52116 (2015). http://dx.doi.org/10.3791/52116 Google Scholar

18. 

A. Tachibana et al., “Parietal and temporal activity during a multimodal dance video game: an fNIRS study,” Neurosci. Lett., 503 (2), 125 –130 (2011). http://dx.doi.org/10.1016/j.neulet.2011.08.023 NELED5 0304-3940 Google Scholar

19. 

G. H. Klem et al., “The ten-twenty electrode system of the International Federation,” Electroencephalogr. Clin. Neurophysiol., 52 (3), 3 –6 (1999). Google Scholar

20. 

A. T. Eggebrecht et al., “A quantitative spatial comparison of high-density diffuse optical tomography and fMRI cortical mapping,” NeuroImage, 61 (4), 1120 –1128 (2012). http://dx.doi.org/10.1016/j.neuroimage.2012.01.124 NEIMEF 1053-8119 Google Scholar

21. 

S. L. Ferradal et al., “Atlas-based head modeling and spatial normalization for high-density diffuse optical tomography: in vivo validation against fMRI,” NeuroImage, 85 (Part 1), 117 –126 (2014). http://dx.doi.org/10.1016/j.neuroimage.2013.03.069 Google Scholar

22. 

M. Okamoto and I. Dan, “Automated cortical projection of head-surface locations for transcranial functional brain mapping,” NeuroImage, 26 (1), 18 –28 (2005). http://dx.doi.org/10.1016/j.neuroimage.2005.01.018 NEIMEF 1053-8119 Google Scholar

23. 

A. K. Singh et al., “Spatial registration of multichannel multi-subject fNIRS data to MNI space without MRI,” NeuroImage, 27 (4), 842 –851 (2005). http://dx.doi.org/10.1016/j.neuroimage.2005.05.019 NEIMEF 1053-8119 Google Scholar

24. 

J. C. Ye et al., “NIRS-SPM: statistical parametric mapping for near-infrared spectroscopy,” NeuroImage, 44 (2), 428 –447 (2009). http://dx.doi.org/10.1016/j.neuroimage.2008.08.036 NEIMEF 1053-8119 Google Scholar

25. 

J. L. Lancaster et al., “Automated labeling of the human brain: a preliminary report on the development and evaluation of a forward-transform method,” Hum. Brain Mapp., 5 (4), 238 –242 (1997). http://dx.doi.org/10.1002/(SICI)1097-0193(1997)5:4<>1.0.CO;2-T Google Scholar

26. 

J. L. Lancaster et al., “Automated Talairach atlas labels for functional brain mapping,” Hum. Brain Mapp., 10 (3), 120 –131 (2000). http://dx.doi.org/10.1002/(ISSN)1097-0193 Google Scholar

27. 

K. J. Friston et al., “Statistical parametric maps in functional imaging: a general linear approach,” Hum. Brain Mapp., 2 (4), 189 –210 (1994). http://dx.doi.org/10.1002/hbm.v2:4 Google Scholar

28. 

R. N. Henson and M. D. Rugg, “Neural response suppression, haemodynamic repetition effects, and behavioural priming,” Neuropsychologia, 41 (3), 263 –270 (2003). http://dx.doi.org/10.1016/S0028-3932(02)00159-8 NUPSA6 0028-3932 Google Scholar

29. 

K. Grill-Spector, R. Henson and A. Martin, “Repetition and the brain: neural models of stimulus-specific effects,” Trends Cognit. Sci., 10 (1), 14 –23 (2006). http://dx.doi.org/10.1016/j.tics.2005.11.006 Google Scholar

30. 

A. Pannese and J. Hirsch, “Self-face enhances processing of immediately preceding invisible faces,” Neuropsychologia, 49 (3), 564 –573 (2011). http://dx.doi.org/10.1016/j.neuropsychologia.2010.12.019 NUPSA6 0028-3932 Google Scholar

Biography

Swethasri Dravida is a graduate student at Yale School of Medicine. She received her BS degree in mathematics and brain and cognitive sciences from Massachusetts Institute of Technology in 2013. Her current research interests include using functional near-infrared spectroscopy and EEG to study social interaction, especially in clinical contexts, such as autism.

Jack Adam Noah received his PhD in biomedical sciences from Marshall University School of Medicine in 2003. He is an associate research scientist at Yale School of Medicine in the Department of Psychiatry and the Brain Function Laboratory. His research interests include functional near-infrared spectroscopy and integration of other multimodal and behavioral recording techniques for applications in communication and social interactions, neurofeedback, and cognitive neuroimaging.

Xian Zhang received his PhD in psychology and visual science from Columbia University in New York in 2003. He is an associate research scientist in the Brain Function Laboratory in the Department of Psychiatry, Yale School of Medicine. His research interests include computational neuroscience, signal processing, and neuroimaging technologies, such as EEG, fNIRS, and fMRI and their applications in psychiatry, vision science, social interactions, and decision making.

Joy Hirsch received her PhD in psychology and visual science from Columbia University and is now a professor of psychiatry and neurobiology, Yale School of Medicine, and a professor of neuroscience, University College London. She is also the director of the Brain Function Laboratory at Yale University. Her research is focused on investigations of neural circuitry that underlies human–social interactions using multimodal neuroimaging techniques, including fNIRS, fMRI, EEG, eye-tracking, and behavioral measures. Prior to recruitment to Yale, she was a director of the fMRI research center at Columbia University.

CC BY: © The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
Swethasri Dravida, Jack Adam Noah, Xian Zhang, and Joy Hirsch "Comparison of oxyhemoglobin and deoxyhemoglobin signal reliability with and without global mean removal for digit manipulation motor tasks," Neurophotonics 5(1), 011006 (14 September 2017). https://doi.org/10.1117/1.NPh.5.1.011006
Received: 8 March 2017; Accepted: 21 August 2017; Published: 14 September 2017
Lens.org Logo
CITATIONS
Cited by 71 scholarly publications.
Advertisement
Advertisement
KEYWORDS
Reliability

Somatosensory cortex

Signal attenuation

Spatial filters

Neurophotonics

Near infrared spectroscopy

Medicine

RELATED CONTENT


Back to Top