1 August 1979 Fiber Optic Rotation Sensor (FORS) Laboratory Performance Evaluation
Author Affiliations +
Abstract
A single axis rotation sensor, utilizing a 200 m single mode optical fiber in a 30 cm diameter coil has been constructed and tested in the laboratory. A HeNe laser is the light source for the Sagnac interferometer-mode sensor. The outputs of Si detectors viewing two complementary interference patterns are electronically differenced to obtain a rotation dependent signal. Linear response over a rotation rate range of about 10-4 to 10-1 rad s-1 was obtained.
Raymond Goldstein, Willis C. Goss, "Fiber Optic Rotation Sensor (FORS) Laboratory Performance Evaluation," Optical Engineering 18(4), 184381 (1 August 1979). https://doi.org/10.1117/12.7972389 . Submission: