1 March 1989 Data Analysis In Fiber Optic Testing Of Cylindrical Optics
Joseph M. Geary
Author Affiliations +
Abstract
Optical fiber testing of positive power cylindrical optics is shown to be bisensitive. This means that the resulting interferogram is twice as sensitive along the cylindrical (zero power) axis as along the orthogonal (power) direction. The analysis of such interferograms is discussed.
Joseph M. Geary "Data Analysis In Fiber Optic Testing Of Cylindrical Optics," Optical Engineering 28(3), 283212 (1 March 1989). https://doi.org/10.1117/12.7976936
Published: 1 March 1989
Lens.org Logo
CITATIONS
Cited by 8 scholarly publications and 8 patents.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Fiber optics tests

Optical testing

Data analysis

Fiber optics

Optical fibers

Back to Top