1 October 1991 Design of an in-water spectrograph for irradiance measurements in the ocean
Author Affiliations +
Abstract
A low focal ratio (f/l.8) visible range (350 nm to 750 nm) spectrograph containing an aberration-corrected concave holographic grating and a 512-channel linear array image sensor has been designed for use in an in-water spectroradiometer. A ray-trace analysis using different input wavelengths has been made, so as to optimize and assess the optics. The design analysis also includes calculations on the expected resolution, system etendue, and the simulated response of the complete system to a known in-water spectrum. The modular design concept of the spectrograph can be exploited by using it as a basic building block for other spectral measurements in the ocean.
Elgar Stephen de Sa, Elgar Stephen de Sa, B. A.E. Desa, B. A.E. Desa, } "Design of an in-water spectrograph for irradiance measurements in the ocean," Optical Engineering 30(10), (1 October 1991). https://doi.org/10.1117/12.55956 . Submission:
JOURNAL ARTICLE
7 PAGES


SHARE
RELATED CONTENT

Folded path LWIR system for SWAP constrained platforms
Proceedings of SPIE (June 24 2014)
Optical Design With A Pocket Calculator
Proceedings of SPIE (June 30 1982)
Geometrical optics: some applications of the law of intensity
Proceedings of SPIE (September 06 2006)
Aberrations Of Holographic Gratings
Proceedings of SPIE (October 26 1983)
NOAO's next-generation optical spectrograph
Proceedings of SPIE (August 16 2000)

Back to Top