1 October 1991 Design of an in-water spectrograph for irradiance measurements in the ocean
Author Affiliations +
Abstract
A low focal ratio (f/l.8) visible range (350 nm to 750 nm) spectrograph containing an aberration-corrected concave holographic grating and a 512-channel linear array image sensor has been designed for use in an in-water spectroradiometer. A ray-trace analysis using different input wavelengths has been made, so as to optimize and assess the optics. The design analysis also includes calculations on the expected resolution, system etendue, and the simulated response of the complete system to a known in-water spectrum. The modular design concept of the spectrograph can be exploited by using it as a basic building block for other spectral measurements in the ocean.
Elgar Stephen de Sa, Elgar Stephen de Sa, B. A.E. Desa, B. A.E. Desa, } "Design of an in-water spectrograph for irradiance measurements in the ocean," Optical Engineering 30(10), (1 October 1991). https://doi.org/10.1117/12.55956 . Submission:
JOURNAL ARTICLE
7 PAGES


SHARE
RELATED CONTENT

Aesthetic message of holography
Proceedings of SPIE (January 31 1991)
Adjustable Mosaic Grating Mounts
Proceedings of SPIE (February 09 1981)
NOAO's next-generation optical spectrograph
Proceedings of SPIE (August 15 2000)

Back to Top