1 January 1992 Measurements of the operating characteristics of a large-area avalanche photodiode
Author Affiliations +
Optical Engineering, 31(1), (1992). doi:10.1117/12.56040
Abstract
We have measured the dark current (Id) and noise equivalent power (NEP) of four large-area (~0.8 cm2) avalanche photodiodes (APD) to determine their sensitivity limit for detecting weak optical communication signals. We found that from room temperature down to about -10°C the Id decreased by one-half for every 8-deg drop in temperature and the NEP decreased by one-half for every 16-deg drop in temperature. Below this temperature, the NEP leveled off at somewhat less than 5 pW in a 100-kHz bandwidth. We describe the measurement technique, present an analysis of the data, and discuss the statistical properties of these APDs according to the model developed by McIntyre et al.
Frederick Martin, Gerald Entine, Richard Farrell, "Measurements of the operating characteristics of a large-area avalanche photodiode," Optical Engineering 31(1), (1 January 1992). http://dx.doi.org/10.1117/12.56040
JOURNAL ARTICLE
5 PAGES


SHARE
KEYWORDS
Avalanche photodetectors

Signal to noise ratio

Signal detection

Interference (communication)

Temperature metrology

Sensors

Avalanche photodiodes