1 November 1997 Study of afterglow in x-ray phosphors for use on fast-framing charge-coupled device detectors
Author Affiliations +
Abstract
There is a need in the x-ray imaging community for phosphors with short persistence (I /Ib<0.1 to 0.01% in less than 0.5 ms). Persistence limits a detector’s performance by defining the minimum xray exposure discernible for a given time after a previous exposure, by ghosting of previous images, and by limiting the dynamic range. We characterize the persistence and relative light output of 25 commercially available and specially synthesized phosphors, five of which are gadolinium oxysulfide (Gd2O2S) with five different activators. The phosphor’s ‘‘practical efficiency’’ is presented for use with either front- or rearilluminated CCDs. The persistence of these phosphors is characterized as a function of x-ray intensity, exposure time, and, when possible, impurity concentrations. Each phosphor’s usefulness for particular x-ray imaging experiments is also discussed.
John A. Shepherd, John A. Shepherd, Sol M. Gruner, Sol M. Gruner, Mark W. Tate, Mark W. Tate, Melvin Tecotzky, Melvin Tecotzky, } "Study of afterglow in x-ray phosphors for use on fast-framing charge-coupled device detectors," Optical Engineering 36(11), (1 November 1997). https://doi.org/10.1117/1.601530 . Submission:
JOURNAL ARTICLE
11 PAGES


SHARE
RELATED CONTENT

Managing radiation degradation of CCDs on the Chandra X ray...
Proceedings of SPIE (September 17 2007)
High Resolution X-Ray-Tv-Sensors
Proceedings of SPIE (January 31 1985)
Thermal neutron imaging
Proceedings of SPIE (March 02 1995)

Back to Top