1 May 2007 Assessment of an instrumented reinforced-concrete bridge with fiber-reinforced-polymer strengthening
Author Affiliations +
Abstract
Field instrumentation is investigated on an in-service highway bridge over a 2-year period. Extrinsic Fabry-Pérot interferometric (EFPI) strain sensors provide a permanent health-monitoring capability. The bridge is a reinforced-concrete (RC) structure that was repaired and strengthened using fiber-reinforced-polymer (FRP) wraps. A sensor network monitors the load-induced strain in the FRP reinforcement and the steel rebar. Colocated electrical resistance strain gauges and a finite element analysis are used for comparison. Both dynamic and static load characteristics are analyzed for a near-capacity truck. The fiber optic measurements are generally consistent with the comparison measurements and the analytical results; and they show no failure or degradation as opposed to the electrical resistance gauges. We demonstrate the implementation and the performance of in situ EFPI sensors in a long-term field environment. Embedded fiber optic sensors can provide the required information for the intelligent management of a transportation infrastructure.
© (2007) Society of Photo-Optical Instrumentation Engineers (SPIE)
Steve E. Watkins, Steve E. Watkins, James W. Fonda, James W. Fonda, Antonio Nanni, Antonio Nanni, } "Assessment of an instrumented reinforced-concrete bridge with fiber-reinforced-polymer strengthening," Optical Engineering 46(5), 051010 (1 May 2007). https://doi.org/10.1117/1.2740758 . Submission:
JOURNAL ARTICLE
10 PAGES


SHARE