Abstract
An optical accelerometer with a bulk-micromachined silicon proof mass and a microfiber loop resonator (MLR) sensor was developed. The MLR was fixed on the surface of the cantilever beam. The proof mass and cantilever beam were fabricated with a two-mask process. An accelerometer with a range of ±20 g and output sensitivity 624.7 mV/g was fabricated. The design, simulation, fabrication, and preliminary results are presented.
© (2010) Society of Photo-Optical Instrumentation Engineers (SPIE)
Chang-Lun Hou, Yu Wu, Xu Zeng, Shuangshuang Zhao, Qiaofen Zhou, Guoguang Yang, "Novel high sensitivity accelerometer based on a microfiber loop resonator," Optical Engineering 49(1), 014402 (1 January 2010). https://doi.org/10.1117/1.3294883 . Submission: