1 September 2011 Simple method for the implementation of subaperture stitching interferometry
Author Affiliations +
Abstract
A simple positioning method is proposed to easily implement a circular subaperture stitching test when the tested optics can be covered by one circle subapertures. In this situation, the border of the phase data image is used to locate the position of the subapertures. The simulation results show that it can provide pixel-level positioning accuracy when the quality of the data image is good. Furthermore, an optimization algorithm is introduced to reduce the positioning error and minimize the mismatch in the overlapping area. Finally, we study the applicability of this method to a subaperture stitching test of a parabolic surface. The stitching results are consistent with the full-aperture test results.
© (2011) Society of Photo-Optical Instrumentation Engineers (SPIE)
Pengfei Zhang, Pengfei Zhang, Hong Zhao, Hong Zhao, Bingcai Liu, Bingcai Liu, Fen Gao, Fen Gao, Jin Huang, Jin Huang, } "Simple method for the implementation of subaperture stitching interferometry," Optical Engineering 50(9), 095601 (1 September 2011). https://doi.org/10.1117/1.3617454 . Submission:
JOURNAL ARTICLE
9 PAGES


SHARE
Back to Top