17 October 2013 Research on zero-sum magnetic field integral technology of optical current sensors
Author Affiliations +
Abstract
An architecture based on the Faraday effect to minimize the crosstalk effect in optical current sensors (OCSs) is proposed. It was demonstrated that the magnetic field integral along a discrete loop can meet Ampere’s law under certain conditions, and the mathematical model of zero-sum points was given. Based on it, a zero-sum OCS (ZOCS) was proposed, which consists of several OCSs forming a symmetrical discrete loop. Ideally, the currents that flow outside the ZOCS do not contribute to the measurement of the currents inside it. The experimental results showed that the magnetic crosstalk-induced errors of ZOCS were less than 0.2%, and the influence of external current was reduced one order compared with conventional OCSs.
© 2013 Society of Photo-Optical Instrumentation Engineers (SPIE)
Shen-wang Li, Wen-bin Yu, Guo-qing Zhang, Zhi-zhong Guo, Yan Shen, "Research on zero-sum magnetic field integral technology of optical current sensors," Optical Engineering 52(10), 104105 (17 October 2013). https://doi.org/10.1117/1.OE.52.10.104105 . Submission: