21 April 2015 Digital holographic movie by using a point diffraction interferometer
Author Affiliations +
Optical Engineering, 54(4), 044104 (2015). doi:10.1117/1.OE.54.4.044104
A method to obtain a digital holographic movie by means of a point diffraction interferometer is described. By using a parallel aligned liquid crystal wave plate of size 3×3  cm2, a phase shifting interferometric technique is implemented. The optical setup is able to operate at 10  frames/s. Each frame can be digitally refocused to reconstruct different planes of the three-dimensional (3-D) object. By changing the frame, the object can be refocused in a different time. As an example, we show a movie which contains two objects that are separated by 160 mm. The movie shows how, for a given time (a fixed hologram frame), we can focus at different planes (separated 0.1 mm) of the 3-D object, and by changing the frame the movement of the object can be observed.
© 2015 Society of Photo-Optical Instrumentation Engineers (SPIE)
Claudio Lemmi, Claudio N. Ramírez, Juan Campos, "Digital holographic movie by using a point diffraction interferometer," Optical Engineering 54(4), 044104 (21 April 2015). https://doi.org/10.1117/1.OE.54.4.044104