A self-calibrated electrical method to measure magnitude response of optical filters is proposed based on dual-frequency-shifted heterodyne. The combined response of optical modulation, filtering, and photodetection is determined from the first frequency-shifted heterodyne, while the reference response of optical modulation and detection is simultaneously obtained from the second frequency-shifted heterodyne, with which the magnitude response of optical filter under test is extracted and self-calibrated. Our method eliminates the extra separate calibration to correct the responsivity fluctuation in the optical modulation and detection. Moreover, it extends double frequency range due to both upper and lower frequency direction measurement at every swept frequency. Magnitude response of optical filter is experimentally measured with our method and compared to that with the conventional method to check its consistency.
© 2016 Society of Photo-Optical Instrumentation Engineers (SPIE)
Xinhai Zou, Xinhai Zou, Shangjian Zhang, Shangjian Zhang, Heng Wang, Heng Wang, Junwei Liu, Junwei Liu, Yali Zhang, Yali Zhang, Rongguo Lu, Rongguo Lu, Yong Liu, Yong Liu, } "Self-calibrated electrical measurement of magnitude response of optical filters based on dual-frequency-shifted heterodyne," Optical Engineering 55(5), 056105 (9 May 2016). https://doi.org/10.1117/1.OE.55.5.056105 . Submission: