25 January 2017 Optimum display luminance dependence on ambient illuminance
Author Affiliations +
Abstract
Viewing high luminance displays under low light conditions causes unbearable glare. On the other hand, viewing low luminance displays under bright light conditions reduces visibility. We investigate the comfortable display luminance range for several different conditions of ambient illuminance through a psychophysical experiment, which involved 30 subjects. The obtained upper (lower) limits of the comfortable zone were 516 (113), 574 (116), 612 (130), 664 (154), 737 (177), 790 (204), and 836 ( 246 )    cd / m 2 , for ambient illuminances of 50, 100, 200, 500, 1000, 2000, and 5000 lx, respectively.
© 2017 Society of Photo-Optical Instrumentation Engineers (SPIE)
Seung-Ryeol Kim, Seung-Hyuck Lee, Dong-Hwan Jeon, Jeong-Sik Kim, Seung-Woo Lee, "Optimum display luminance dependence on ambient illuminance," Optical Engineering 56(1), 017110 (25 January 2017). https://doi.org/10.1117/1.OE.56.1.017110 . Submission: Received: 17 August 2016; Accepted: 4 January 2017
Received: 17 August 2016; Accepted: 4 January 2017; Published: 25 January 2017
JOURNAL ARTICLE
7 PAGES