1 September 2005 Characterizing the thermally induced structural changes to intact porcine eye, part 1: second harmonic generation imaging of cornea stroma
Hsin-Yuan Tan, Shu-Wen Teng, Wen Lo, Wei-Chou Lin, Sung-Jan Lin, Shiou-Hwa Jee, Chen-Yuan Dong
Author Affiliations +
Abstract
We characterize the structural changes of porcine corneal structures from 25 to 90°C using second harmonic generation (SHG) microscopy. Our results show that porcine stroma undergoes several distinct stages of structural changes between 25 and 90°C. A decrease in SHG intensity from 30 to 45°C and the existence of SHG intensity peaks at 53, 65, and 77°C correlate to distinct structural alterations of the corneal stroma. At higher temperatures, the SHG intensity decreases and a baseline in SHG signal is reached at 90°C. Our results demonstrate that SHG microscopy is a useful technique for obtaining qualitative and quantitative information of thermally treated corneal fibers without histological or labeling procedures. With additional developments, SHG imaging may be developed into an effective imaging technique for in vivo characterization of cornea structural changes.

1.

Introduction

The ability to monitor corneal structural changes is important in many ophthalmologic applications. Surgical procedures such as conductive keratoplasty and laser thermokeratoplasty depend on the structural alteration of corneal structure in achieving vision correction.1, 2 Since the cornea is a highly transparent object, the development of an effective imaging technique to obtain both qualitative and quantitative information of corneal structural changes without histological or labeling procedures can be a useful technology in guiding surgery and other therapeutic procedures in ophthalmology. Presently, histological techniques remain the most commonly used imaging platform in characterizing corneal changes.3, 4, 5, 6 However, the development of nonlinear optical microscopic techniques offers an exciting imaging modality capable of circumventing the drawbacks of conventional histological procedures. While second harmonic generation (SHG) was used to image crystalline structures in the 1970s, the biomedical applications of nonlinear optical microscopy flourished with the introduction of two-photon fluorescence microscopy pioneered by Webb’s group in 1990.7, 8, 9 There are a number of important advantages in the applications of nonlinear optical microscopy. First, since the excitation probability is proportional to the square of excitation intensity, sample excitation only occurs effectively at the focal point. Therefore, microscopic imaging with this technique results in images with excellent axial-depth discrimination without using confocal detection. In addition, since photodamage only occurs at the focal point, the overall specimen damage is greatly reduced. Finally, since the near-infrared laser sources used in multiphoton microscopy are absorbed and scattered less than the ultraviolet or visible photons used in one-photon excitation microscopy, multiphoton imaging allows greater sample depths to be achieved without histological procedures.10

In harmonic generation imaging, the nonlinear polarization effect at a high electric field can be used to explore a sample’s microscopic structures. In general, the polarization P of a material can be expressed as

Eq. 1

P=χ1E+χ2EE+χ3EEE+,
where χ1 , χ2 , and χ3 are, respectively, the first-, second-, and third-order susceptibility tensors, and E and represent the external electric field and tensor product operation, respectively. In a material with noncentrosymmetric symmetry, a nonvanishing second-order susceptibility tensor χ2 contributes to a second harmonic generation (SGH) signal, where the angular frequency of the incident electric field frequency ω is converted into photons with frequency 2ω .11 In particular, it is known that the unique 3-D molecular structure of collagen 1 leads to SHG signal and that such a signal can lead to imaging of the cornea stroma.12, 13, 14, 15 In this work, we demonstrate the application of SHG microscopy to obtain qualitative and quantitative information of thermal damage to cornea in intact porcine eyes. Our results show that SHG microscopy can be applied to characterize structural changes to the cornea without histological or labeling procedures.

2.

Methods

2.1.

Second harmonic generation microscopy

The experimental setup of our SHG microscope is similar to a multiphoton microscope previously described.11 In this experiment, the 880-nm output of a diode-pumped solid state (DPSS) laser (Millennia X, Spectra Physics, Mountain View, California) pumped, titanium-sapphire laser (Tsunami, Spectra Physics) was used as the SHG source. To control the laser power and circularize the laser output, a combination of a half-wave plate, polarizer, and quarter-wave plate was used. The circularly polarized laser is guided toward an x-y scanner system (Model 6220, Cambridge Technology, Cambridge, Massachusetts), where angular deviations along the x and y axes are achieved. The scanned beam is directed into an upright microscope (E800, Nikon, Japan) using additional optics. The input of the microscope was modified to accommodate a pair of lenses for beam expansion. The 880-nm laser source is first beam expanded and then reflected toward the focusing, oil immersion objective (Plan Fluor, 20× NA 0.75) by a dichroic mirror (720DCSPXR, Chroma Technology, Brattleboro, Vermont). For the objective with NA of 0.75, we can estimate the size of the focal spot from diffraction theory. The radial and axial spot sizes are 1.22λNA and 4λNA2 ( λ is the laser wavelength used in focusing), respectively.16 For the wavelength of 880 nm, the radial and axial focal sizes are estimated to be 1.4 and 6.3μm . In this fashion, the angular deviation of the x-y scanning system is translated to linear scanning of the focal spot across the cornea specimens. An average power of around 24 mW at the specimens was used for second harmonic signal generation. The SHG signal generated from the corneal collagen fibers was collected in the back-scattering geometry by the same focusing objective. After passing through the short-pass, dichroic mirror, an additional bandpass filter centered at 440 nm (HQ440/40, Chroma Technology) was used to isolate the SHG signal. The photodetector used in these experiments was a single-photon counting photomultiplier tube (R7400P, Hamamatsu, Japan).

In this fashion, a SHG scan of the cornea specimen can be achieved. Each image we acquired is composed of 256×256 pixels (pixel spacing 0.86μm ), and the measured intensity represents the detected SHG photons per pixel. To obtain both high resolution and large area imaging of the cornea specimens, an x-y sample scanning stage (H101, Prior Scientific, United Kingdom) was used to translate the cornea specimen after each 256×256 pixel image was acquired. The movement of the sample scanning stage allowed the acquisition of partially overlapping SHG images from different positions of the specimen. Each large area scan was composed of a 6×6 array of the 256×256 pixel SHG images, and they are later assembled to generate a large area image 880×880μm2 in size.

2.2.

Porcine cornea

The cornea specimens used in this experiment were freshly acquired from local markets at the earliest possible time after sacrifice. Intact porcine eyes were acquired from the markets at around 6 AM. The estimated sacrifice time of the pigs was around 3 AM. According to the vendor, the pigs were slaughtered at around 4 months of age using electric tools. Possible deterioration to the porcine eyes can lead to their opaqueness. However, the porcine eyes used in our experiments were examined to ensure optical clarity in the cornea. At each temperature, three sets of porcine eyes were used to ensure statistical significance in our results. As soon as the porcine eyes were brought back to the laboratory, extraocular muscles were removed and the eyes were immersed in PBS buffer at the ambient temperature. A temperature bath (B206, Firstek, Taiwan) was used to heat the PBS buffer in which the intact porcine eyes were immersed. The digital indicator of the temperature bath allowed the reading of the temperature reading to a precision of ±0.1°C . After the PBS bath reached the desired equilibrated temperature, the porcine eyeballs were placed into the heated buffer bath for 5 min. From a previous study in measuring the thermo-mechanical properties of porcine cornea, the treatment time of 5 min is a reasonable estimate for the porcine cornea to reach thermal equilibrium.17 In this work, we present data that include 18 temperatures ranging from 25 to 90°C. At the end of the thermal treatment cycle, the porcine eyes were removed and mounted inside an empty cover glass container filled with PBS buffer, covered with a standard number 1.5 cover glass, and mounted on the upright microscope for SHG imaging. By adjusting the relative distance between the objective and the cornea sample, the surface of the cornea can be found. Once a scanned SHG image of the corneal surface is acquired, sequential images between adjacent positions of the cornea can be acquired. The SHG images were acquired with the corneas still attached to the eyes, and no excision of the corneas was done. Since the natural state of the porcine cornea is a curved structure, we estimated that the SHG images obtained in this fashion were between 0 and 7μm from the corneal surface, and the measured SHG intensity represents an average value of the porcine cornea within this thickness. Since the porcine eyes were constantly placed in PBS buffer, they remain well hydrated. To acquire statistically significant results, at each temperature, three porcine eyes were used for SHG microscopic imaging. The analysis of the thermal effects on cornea collagen is completed in two ways. First, the large area SHG images are compared to the histological images. Furthermore, quantitative analysis is performed by averaging the SHG intensity across the large area scan. For each temperature, the results of the SHG intensity from three sets of porcine corneas were averaged and plotted.

After SHG imaging of the cornea specimens was completed, the samples were fixed in the formalin:PBS solution (1:9vv) for histological processing. The processing of the porcine eye specimens was completed within 3 h. Histological specimens of the thermally treated porcine corneas were prepared according to conventional histological procedures. The formalin:PBS stored porcine eyes were dehydrated and imbedded in paraffin. Thin sections with thicknesses around 5μm were prepared and labeled using hematoxylin and eosin (HE). The corneal collagen was labeled by eosin, which gives it the characteristic pinkish appearance. The histological images presented were obtained close to the corneal regions where the multiphoton imaging was performed.

3.

Results

Using SHG microscopy, we acquired large area scans of the porcine corneas treated for 5 min at different temperatures from 25 to 90°C. Shown in Fig. 1 are a representative set of the cross-sectional SHG images of the cornea stroma of 18 temperatures at 25, 30, 35, 40, 45, 50, 53, 56, 59, 62, 65, 68, 71, 74, 77, 80, 85, and 90°C. In each panel, the SHG images (left figures) are presented using the displayed color scale for indicating the minimum and maximum intensities used for display. For comparison, the corresponding HE images at each temperature are shown (right figures) for comparison.

Fig. 1

Large area second harmonic images (left figures: 880×880μm2 ) and HE images of porcine cornea after 5 min treatment at the respective temperatures.

054019_1_031504jbo1.jpg

In this manner, similar comparison between the SHG and HE images can be made. Visual examination of Fig. 1 reveals several important features. First, the collagen fibers associated with cornea stroma are clearly visible under SHG imaging. Furthermore, the SHG intensity changes as a function of temperature. Visual examination of the SHG images in Fig. 1 shows that with increasing temperature, distinct changes in SHG intensity occur. From 25 to 45°C, SHG intensity appears to decrease with increasing temperature. However, starting at 50°C, the SHG intensity increases and reaches maximum values between 50 and 71°C. With additional increase in temperature, SHG intensity starts to decrease. However, an additional maximum in SHG signal is observed at around 74 to 77°C. As the temperature continues to increase, the SHG signal decreases until 90°C, where the SHG intensity has reached a baseline value. The corresponding histological images show that at temperatures less than 53°C, the stroma collagen are organized into visible fibers. From 56 to 74°C, regions of the cornea appear to have been grouped into forming separate domains without the finer fibrous structures visible at lower temperatures. The appearance of cavities is also apparent at these higher temperatures. At temperatures higher than 77°C, the number of distinct domains decreases within the cornea. At 90°C, the histological image shows that the corneal collagen has merged into a continuum distribution of mass with no discernible microscopic features. To add statistical significance to our data, the intensity from the SHG images from two additional porcine eyes were measured and averaged. The statistical analysis of SHG intensity from the set of three porcine eyes at each temperature is shown in Fig. 2 .

Fig. 2

Second harmonic intensity of porcine cornea stroma as a function of treatment temperature (5 min).

054019_1_031504jbo2.jpg

The plot in Fig. 2 shows that at 25 and 30°C, the SHG intensities are essentially the same (within experimental error). In the higher temperature range between 35 and 45°C, SHG intensity decreased. As the temperature further increases, the SHG intensity first increases to a peak at 53°C before reaching a main peak at 65°C. With additional increase in temperature, the SHG signal first decreased and then increased to a secondary peak at around 74 to 77°C. As the temperature continues to increase, the SHG intensity monotonically decreases to the background intensity at 90°C. Note that these observations are difficult to confirm from the histological images alone. The sharp rise in SHG intensity at 65°C can be attributed to a sharp, irreversible structural change of the cornea stroma at that temperature.

4.

Discussion

By applying SHG imaging to thermally treated cornea specimens in intact porcine eyes, we have shown that the collagen fibers of cornea stroma undergo four distinct structural changes in the temperature range between 25 to 90°C. First, between 30 and 45°C, the cornea fibrous structures remain largely intact. With additional increase in temperature, the corneal SHG intensity starts to increase and first reaches a peak value at 53°C before reaching a main peak at 65°C. Histological examination of the cornea at 53°C shows that although the collagen fibers remain visible, they have grouped into domains separated by cavities. This phenomenon becomes even more apparent as the temperature increased. Finally, at 90°C, the cavities are no longer visible and the cornea specimen seems to have merged into one continuous structure. These observations suggest that the SHG signal peaks observed at 53, 65, and 74 to 77°C correspond to the organization of collagen fibers into locally dense bundles made possible by the thermal disruption of cross-linking elements in the corneal stroma. The existence of multiple peaks suggests that the reorganization of corneal collagen occurs at three distinct phases between 53 and 77°C, corresponding to different strengths of cross-linking within corneal collagen. The absence of organized histological structure and the lack of SHG signal at 90°C suggest that at sufficiently high temperatures, neither the cross-linking nor the hydrogen bonds within corneal stroma has the strength to maintain the noncentrosymmetric structure of collagen fibrils responsible for generating the SHG signal.

It is interesting to compare our results with the differential scanning calorimetry (DSC) data from porcine corneas published previously. It was shown that the porcine cornea starts to undergo thermal denaturation at 54.5°C. At higher temperatures, porcine cornea absorbs more heat, reaching a maximum absorption temperature at 64.8°C. As the temperature further increases, the slope in the DSC thermogram changes until a baseline value is reached at 81.8°C. It was suggested that the slope changes in a DSC thermogram between 64.8 and 81.8°C correspond to the existence of subprocesses.17 Since we detected changes in SHG intensity starting at 30°C, while the DSC thermogram did not reveal corresponding changes in heat flow, it seems that SHG imaging is a more sensitive technique capable of detecting more subtle changes in corneal structures. In addition, since the same primary maximum transition temperature was measured using both techniques (SHG 65°C; DSC 64.8°C), SHG imaging is able to detect the structural change measured using DSC. Furthermore, the temperature range where DSC data indicated the existence of subprocesses also corresponds well to the SHG intensity diagram. Specifically, the SHG intensity plot demonstrated a variation in slope and the existence of a secondary SHG peak at 77°C. Despite the similarities of the SHG and DSC results, several differences do exist. First, the difference in baseline temperature (SHG 90°C; DSC 81.8°C) may be interpreted by the fact that we used intact porcine eyes for SHG imaging, while small excised corneal specimens were used in DSC measurements. The additional mechanical support provided by the sclera in maintaining the corneal structure in intact eyes may alter the response of thermally treated corneal collagen. Secondly, SHG imaging reveals a local maximum at 53°C. Such a change is missing in the DSC data, suggesting that the microscopic SHG imaging technique is more sensitive in revealing microscopic structural changes than the macroscopic heat flow measurement using DSC.

This work demonstrates that the nonlinear imaging modality of second harmonic generation microscopy may be used to obtain qualitative and quantitative information of collagen structural alterations in the cornea. Although SHG intensity is a far-field optical technique with spatial resolution in the micron range, the changes in SHG intensity are sensitive to alterations in cornea structures responsible for the second-order susceptibility tensor χ2 and other changes at the tissue level. In addition, since SHG microscopy depends on the intrinsic fiber orientations for signal generation, invasive histological or labeling procedures are not needed to obtain structural information valuable in guiding surgery and other therapeutic procedures of the cornea. Furthermore, since the SHG signal is a polarization effect rather than molecular excitation used in fluorescence microscopy, there is minimal photodamage to the specimens. Therefore, unlike other optical imaging techniques, SHG microscopy has the potential to be developed into an effective imaging technique for in vivo characterization of corneal structures. Our results show that SHG microscopy can be a valuable addition to the repertoire of imaging techniques in determining corneal structures, and may be developed into an effective imaging technology useful in guiding surgery and characterizing tissue engineered products intended for corneal repair.

Acknowledgment

The authors acknowledge the support from the National Research Program for Genomic Medicine, National Science Council, Taiwan (NSC 93–3112–B-002–033 and 94–3112–B-002–015–Y) for this project

References

1. 

M. B. McDonald, P. S. Hersh, E. E. Manche, R. K. Maloney, J. Davidorf, and M. Sabry, “Conductive keratoplasty for the correction of low to moderate hyperopia: US clinical trial 1-year results on 355 eyes,” Ophthalmology, 109 (11), 1978 –1989 (2002). https://doi.org/10.1016/S0161-6420(02)01255-1 0161-6420 Google Scholar

2. 

R. Brinkmann, B. Radt, C. Flamm, J. Kampmeier, N. Koop and R. Birngruber, “Influence of temperature and time on thermally induced forces in corneal collagen and the effect on laser thermokeratoplasty,” J. Cataract Refractive Surg., 26 (5), 744 –754 (2000). https://doi.org/10.1016/S0886-3350(00)00310-2 0886-3350 Google Scholar

3. 

M. N. AsiyoVogel, R. Brinkmann, H. Notbohm, R. Eggers, H. Lubatschowski, H. Laqua, and A. Vogel, “Histologic analysis of thermal effects of laser thermokeratoplasty and corneal ablation using Sirius-red polarization microscopy,” J. Cataract Refractive Surg., 23 515 –526 (1997). 0886-3350 Google Scholar

4. 

D. D. Koch, T. Kohnen, J. A. Anderson, P. S. Binder, M. N. Moore, R. F. Menefee, G. L. Valderamma, and M. J. Berry, “Histologic changes and wound healing response following 10-pulse noncontact holmium:YAG laser thermal keratoplasty,” J. Refract. Surg., 12 (5), 623 –634 (1996). https://doi.org/10.1006/nimg.2000.0657 1081-597X Google Scholar

5. 

T. Kohnen, S. E. Husain, and D. D. Koch, “Corneal topographic changes after noncontact holmium:YAG laser thermal keratoplasty to correct hyperopia,” J. Cataract Refractive Surg., 22 (4), 427 –435 (1996). 0886-3350 Google Scholar

6. 

T. Tanaka, S. Furutani-Miura, M. Nakamura, and T. Nishida, “Immunohistochemical study of localization of extracellular matrix after holmium YAG laser irradiation in rat cornea,” Jpn. J. Ophthalmol., 44 (5), 482 –488 (2000). 0021-5155 Google Scholar

7. 

R. Hellwarth and P. Christensen, “Nonlinear optical microscopic examination of structure in polycrystalline ZnSe,” Opt. Commun., 12 (3), 318 –322 (1974). https://doi.org/10.1016/0030-4018(96)00063-6 0030-4018 Google Scholar

8. 

J. N. Gannaway and C. J.R. Sheppard, “1978. Second-harmonic imaging in the scanning optical microscope,” Opt. Quantum Electron., 10 435 –439 (1978). https://doi.org/10.1007/BF00620308 0306-8919 Google Scholar

9. 

W. Denk, J. H. Strickler, and W. W. Webb, “2-photon laser scanning fluorescence microscopy,” Science, 248 (4951), 73 –76 (1990). 0036-8075 Google Scholar

10. 

P. T.C. So, C. Y. Dong, B. R. Masters, and K. M. Berland, “Two-photon excitation fluorescence microscopy,” Annu. Rev. Biomed. Eng., 2 399 –429 (2000). https://doi.org/10.1146/annurev.bioeng.2.1.399 1523-9829 Google Scholar

11. 

S. H. Lee, Y. Liu, H. C. Chen, L. L. Chiou, G. T. Huang, W. Lo, and C. Y. Dong, “Optical biopsy of liver fibrosis by use of multiphoton microscopy,” Opt. Lett., 29 (22), 2614 –2616 (2004). https://doi.org/10.1364/OL.29.002614 0146-9592 Google Scholar

12. 

P. J. Campagnola and L. M. Lowe, “Second-harmonic imaging microscopy for visualizing biomolecular assay in cells, tissues and organisms,” Nat. Biotechnol., 21 (11), 1356 –1360 (2003). https://doi.org/10.1038/nbt894 1087-0156 Google Scholar

13. 

W. R. Zipfel, R. M. Williams, R. Christie, A. Y. Nikitin, B. T. Hyman, and W. W. Webb, “Live tissue intrinsic emission microscopy using multiphoton-excited native fluorescence and second harmonic generation,” Proc. Natl. Acad. Sci. U.S.A., 100 (12), 7075 –7080 (2003). https://doi.org/10.1073/pnas.0832308100 0027-8424 Google Scholar

14. 

A. Zoumi, A. Yeh, and B. J. Tromberg, “Imaging cells and extracellular matrix in vivo by using second-harmonic generation and two-photon excited fluorescence,” Proc. Natl. Acad. Sci. U.S.A., 99 (17), 11014 –11019 (2002). https://doi.org/10.1073/pnas.172368799 0027-8424 Google Scholar

15. 

A. T. Yeh, N. Nassif, A. Zoumi, and B. J. Tromberg, “Selective corneal imaging using combined second-harmonic generation and two-photon excited fluorescence,” Opt. Lett., 27 (23), 2082 –2084 (2002). 0146-9592 Google Scholar

16. 

C. Y. Dong, P. T.C. So, C. Buehler, and E. Gratton, “Spatial resolution in pump-probe microscopy,” Optik (Jena), 106 7 –14 (1997). 0030-4026 Google Scholar

17. 

J. Kampmeier, B. Rodt, R. Birgruber, and R. Brinkmann, “Thermal and biomechanical parameters of porcine cornea,” Cornea, 19 (3), 355 –363 (2000). https://doi.org/10.1097/00003226-200005000-00020 0277-3740 Google Scholar
©(2005) Society of Photo-Optical Instrumentation Engineers (SPIE)
Hsin-Yuan Tan, Shu-Wen Teng, Wen Lo, Wei-Chou Lin, Sung-Jan Lin, Shiou-Hwa Jee, and Chen-Yuan Dong "Characterizing the thermally induced structural changes to intact porcine eye, part 1: second harmonic generation imaging of cornea stroma," Journal of Biomedical Optics 10(5), 054019 (1 September 2005). https://doi.org/10.1117/1.2012987
Published: 1 September 2005
Lens.org Logo
CITATIONS
Cited by 46 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Second-harmonic generation

Cornea

Collagen

Microscopy

Harmonic generation

Temperature metrology

Optical fibers

Back to Top