|
1.IntroductionIt is much easier to construct a numerical model of the human eyeball nowadays than it was ago due to advances in professional software programs for construction design based on finite element analysis (FEA). Such programs allow the construction of models of a complete eye globe with complicated geometry that possess both nonlinear and anisotropic materials.1, 2 However, most of the work done with such numerical tools has been dedicated to the specific elements of the eye globe, and in particular to the cornea and its mechanical properties, before and after corneal refractive surgery.3, 4, 5 Also, there has been a continuous effort to model and analytically describe the mechanical properties of the eye using closed-form expressions.6, 7 Thus, it would appear that biomechanical modeling of the eyeball should have been resolved and that the accuracy of such a model would only be a matter of performing a larger number of iterations to find the numerical solution. However, notwithstanding the efforts that are being made toward development of accurate algorithms, current eye models are still far from describing the behavior of a real human eye. The reason for this is rather prosaic. Despite the eye’s apparent structural simplicity, the in vivo mechanical properties of the human eye have not been categorically described. Using the words of Shin 8 in referring to the cornea, “experimental data is [often] meagre and flawed.” Detailed knowledge of the structure of all eyeball tissue components (i.e., cornea, sclera, iris, lens, choroid, and retina) as well as their material properties (nonlinear and anisotropic) is needed. Two of these eyeball components, the cornea and the sclera, are fairly well described when it comes to their geometries, but their material properties have been disputed. 8, 9, 10, 11, 12, 13, 14 On the other hand, knowledge of the in vivo mechanical properties of the other components of the eye is very limited. As a result, most reported biomechanical models of the human eyeball contain the cornea and the sclera, and sometimes the optic nerve,15 but omit the other components. Another deficiency in the majority of reported biomechanical models of the eyeball is the developers’ apparent low interest in the optics of the eye. Most authors develop their models as if the eye was a strictly mechanical structure while its optics was just a simple consequence of the mechanical parameters, which are often chosen ad hoc. Subsequently, this often leads to problems with accurate mechanical identification. To date, optical properties of the eye are hardly used to identify the mechanical parameters of the eyeball model.16 In this work we postulate that the optical functions of the eye have strongly influenced its mechanical structure; that it is the optics of the eyeball that took, in the evolution process, control over the mechanics (in terms of geometry and material parameters) and subjected it toward its needs.17 It is well known from studies on a variety of species that there is a direct role of vision in the material properties of the eye and in regulation of its growth.18, 19 Therefore, it is highly likely that the material properties of the eye must have been selected by nature to optimize the optics and visual function in the first place. Thus, biomechanical modeling of the eyeball should include some relationships between the mechanical and optical parameters of the eye so the goal of developing an accurate mechanical eyeball model can be achieved. Using this concept, we develop a numerical model of an eyeball in which the structural parameters (in terms of the eyeball geometry and its material properties) are linked to the optical function of the eye. This is achieved by controlling in the model all essential optical functions of the eye while still assuming material properties from the range of those available in the literature experimental results.20, 21, 22, 23 By combining the mechanical and optical functions of the eye in the model, the number of free model parameters significantly decreases, which makes the model more robust and the comparison between any two model conditions more tractable. 2.MethodsA model of the eyeball is defined as a set of geometrical and material parameters in the design of a mechanical construction that can be solved using the finite element method (FEM). In this view, the type of the elements used or the particular solution parameters of the FEM is of some importance, as they may have a significant impact on the accuracy of the solution. 2.1.The FEM ModelThe model that we use to link the mechanical properties of the eye to its optical functions is built from a 2-D quadrilateral 8-node body of revolution elements. More than 500 of such elements were used. The solution parameters include both the nonlinear material effects as well as the changes in the construction configuration under loading. A typical distribution of the density of elements used in our model is shown in Fig. 1 . The boundary conditions (model mounting) limit the movements of the construction as a rigid body; otherwise the model is allowed to move freely. The model includes three kinds of material properties corresponding to the cornea, sclera, and limbus (the circled area in Fig. 1). The only material that can remain linear in a model and satisfy optical self-adjustment is that of the limbus. Its Young’s modulus is set to . All numerical calculations have been performed using Cosmos/M™.24 2.2.Assumption of Optical Self-AdjustmentThe phenomenon of optical self-adjustment of the eye can be observed during an increase in intraocular pressure (IOP). One would expect that an increase in IOP could result in a slight expansion of the eyeball and the following sequence of actions:
2.3.Model GeometryWe approximate the anterior and posterior surfaces of the cornea by spheres similar to the Gullstrand—Le Grand model,27 making sure that the data follow the available knowledge based on experimental measurements. The nominal parameter values for the considered eyeball are shown in Table 1 for a model under no load. Changes of these parameters with the increasing level of IOP will be shown later. The sclera is modeled as a anterior radius sphere with varying thicknesses: near the limbus, in the equatorial area, and about in the foveal region (see Fig. 1). Table 1Main parameters of the considered model of the eyeball.
The corneal surfaces are better modeled by aspheric surfaces, such as an ellipsoid,31, 32 because those shapes correspond better to keratometric measurements of real corneas than a sphere. In our previous study on optical self-adjustment,16 we did consider an elliptic shape with eccentricity . This result, however, was achieved for a linear model. Here, we decided to use the classical spherical model of the cornea so we could first study the behavior of a model with nonlinear materials. 2.4.Boundary ConditionsThere is no agreement in the literature on how the model of the eyeball should be mounted despite the fact that there are many studies devoted to orbital mechanics of the eye.33, 34, 35, 36 For obvious reasons, those analytical models that consider the corneal surface only have either a roller or a fixed support.12, 13, 14 However, such simplified mountings are also considered in numerical models.3, 8, 37 As we will show later, this could lead to misinterpretation of the numerical results, particularly when dealing with the optical function of the eye. A recent in vivo study on corneal rigidity38 supports the assumption of free mounting the eyeball, which we will also adopt here. 2.5.MaterialsThe anterior surfaces of cornea and sclera have been well documented and their physical structures are known.39 However, the knowledge of their mechanical properties is less complete. It is known that the materials are nonlinear, anisotropic, and that under a large load, their rheological properties must be taken into account. Fortunately, not all of these aspects need always to be considered. In particular, for a model of a normal living eye, one can assume an isotropic and elastic material. However, this material must be nonlinear. Here we also restrict ourselves to only one layer of corneal tissue, and from this point onward we identify the cornea with the stroma. This simplification does not significantly reduce the accuracy of the solution,2 since it appears that the Young’s modulus of the Descemet’s membrane is much smaller than that of the stroma.40 The stress-strain functional relationship, , that can be used to characterize the eye surface materials can be expressed in the known exponential form39, 41 where and are constants related to material properties. This functional relationship has an important property that its derivative, known as the tangential modulus of elasticity, is nonzero for strain values approaching zero, i.e.,For the negative stress, we will assume that the material properties are governed by a linear relationship:The anisotropy of the secant modulus of elasticity, dependent on the sign of the strain, is associated with the molecular structures of the stroma and sclera.39 The constitutive Eqs. 1, 3 approximate mechanical functions of a real human cornea, particularly in a clinically relevant range of IOP. The secant modulus of elasticity is often expressed in a form . In our case, the secant modulus of elasticity is given byDespite the fact that expression 4 is a function, we will still call it a modulus. It should, however, be distinguished from the Young’s modulus, which is constant and used for linear materials only.In the analysis of the stress state present in ocular surfaces under IOP, we also need to consider the value of another variable: the Poisson’s ratio. The limit of the Poisson’s ratio for an isotropic incompressible material (e.g., water) is , and in some works it has been used to describe corneal tissue.3, 42 However, this limit value cannot be used in our modeling, because the stress-strain relationship in this case is no longer uniquely described. For this reason, we consider Poisson’s ratio values of the eye constructions values that are just below this limit. The problem is that Poisson’s ratios ranging from through to are being reported.2, 8, 37, 43, 44 However, this wide range of values is being disputed, because some of the considered values are supported by real measurements.1, 45 In some cases, the use of real measurements and the belief that they are correct may lead to an unrealistic situation. See, for example, the work of Pandolfi and Manganiello,37 where the chosen values of the secant modulus of elasticity and the Poisson’s ratio led to unrealistically low values of the bulk modulus. In our opinion, such a discussion is of no serious significance because the model solution only marginally depends on the Poisson’s ratio. If we assume that the bulk modulus of elasticity of considered soft tissues is of the same order as that of water ( ), that is , while their secant (Young’s) modulus of elasticity is about three orders smaller, i.e., , then the Poisson’s ratio is It is worth noting that varying the parameters and within the range of values that can be attributed to ocular tissues does not change this ratio significantly (see the mostly flat region of the relationship in Fig. 2 ). For this reason, we will assume in our modeling the value of .The material parameters of the considered biomechanical model of the eyeball have been chosen in a way so that the model results match those of the Goldmann applanation tonometry.46 Despite its deficiencies it is still the most widely accepted method of determining intraocular pressure.47, 48 In this technique, the cornea is modeled as a membrane filled with fluid under certain pressure. Then, using a specially calibrated probe, a small force is applied to the central -diameter flattened corneal area, which in turn exerts a force directly related to the internal pressure as per the so-called Imbert-Fick law. Identification of the corneal material parameters with the Goldmann’s test showed that, to adequately represent the performance of a real eye in our modeling, the following criteria must be met:
The assumption that the model satisfies the principle of optical self-adjustment leads to another structural condition. Specifically, for a given stress value, the secant modulus of the sclera must be several times larger than that of the cornea. By denoting this relationship by it follows that the material used for the sclera is given by the following stress-strain function:where the constant is the same as the one used for the cornea. We have determined ratio in our preliminary studies to be in the range between 4.6 and 6. This ratio has its significance even in a linear model of the eyeball49 and has its confirmation in experimental studies.9We have numerically validated this proposed nonlinear model by comparing its stiffness to that of a real eye.38, 50 In this particular aspect, material showed much better performance than that given by material . That is why in the remaining part of this paper we will only consider the corneal model realized from material . The material for the sclera, on the other hand, satisfies relationship 8 with . Finally, the main role of the limbus in the model is to “optically couple” the cornea and sclera so that optical self-adjustment is satisfied. The limbus is defined as an annular transition zone between the cornea and sclera. Histologically, at the limbus, the epithelium gradually thickens toward the sclera where it is replaced by conjunctival tissue. In our modeling, we simplify this limbus area to a limbus ring with mechanical properties that are between those of the cornea and sclera. Since the secant modulus of the cornea is close to and that of the sclera is times larger, i.e. , the modulus for the limbus must be set between these two values, say , so that the structure is not perturbed. 2.6.Optical System of the EyeballThe total optical power of the eye depends on the respective powers of the cornea and crystalline lens and their mutual positions (i.e., distance ). Figure 1 shows the optical system and the notation used. The parameters of the eyeball are given in Table 1. Changes in the pressure influence the optical power of the cornea (by changing its axial curvature ) as well as the distance between the cornea and the crystalline lens. The optical power of the eyeball is given by. while its focal length isHere it is assumed that the power of the lens is constant, but the distance and the power of the cornea,depend on the pressure . Both and are obtained from the FEM solution. The above formula describes the optical power of the anterior corneal surface that divides areas of significantly different refractive indices (i.e, for air, and for the cornea). The contribution of the posterior corneal surface to total power changes is just above 1%. However, this contribution is much lower when changes in optical power are considered. That is why we remain with formula (11) in all further calculations.The displacement of the focal point with respect to the back of the eye is influenced not only by the changes in optical power of the cornea-crystalline-lens interface, but also by the “optical” elongation of the eyeball, which is understood here as a shift of the secondary principal plane with respect to the back of the eye. Thus, displacement of the focal point is composed of the axial elongation of the sclera (i.e., axial translation of the crystalline lens ) and the change in the distance between the crystalline lens and the second principal plane (see Fig. 1), The distance is given bywhile the axial translation of the crystalline lens is obtained from the FEM solution.Finally, the displacement in focus (positive sign toward the cornea) is given by The function can be treated as a measure of optical blur on the retina. If its change is due to the intraocular pressure , then the criterion of optical self-adjustment can be analytically expressed asThe deformation of the sclera has a crucial role in the above criterion. Thus, studying optical self-adjustment in models that contain only the corneal surface that is fixed at its perimeter is an oversimplification.The property of optical self-adjustment determines the ratio of the corneal longitudinal modulus of elasticity to that of the sclera (parameter ). Together with the material properties of the cornea, they “automatically” determine the parameters of the sclera and limbus, hence reducing the number of free parameters used in the model. 3.Results3.1.Full ModelFirst, we consider a full model of the eyeball with standard geometry (see Table 1), material , and free movement mounting under internal load . The free model parameters include the thickness of the sclera ( near the limbus, in the equatorial area, and about in the foveal region), the central corneal thickness (CCT), peripheral corneal thickness adjacent to the limbus (PCT), central anterior radius of curvature, parameters and of the corneal material, and the ratio . Figure 4 shows the solutions of the FEM for several functions dependent on . The load was applied in steps and the FEM solutions were fast-converging. The solutions include , the displacement in the focus; , the central anterior corneal radius of curvature; and , the axial and radial displacements of the limbus; and , the axial displacement of the corneal apex. Comparing the displacement in the focus with the displacements in the corneal curvature and limbus, we note that they are all of the same order, say about . However, function shows that for the pressure larger than , the changes in displacement of focus are much smaller; thus, the model fullfills the criterion of optical self-adjustment. Note also that because the cornea has a flexible mount at the limbus, its radius of curvature increases with the pressure . Figure 5 shows the radial profile of the anterior cornel surface for the same seven loads considered in Fig. 4, i.e., from in steps of , and additionally for , for which the displacements are most rapid. 3.2.Fixed Cornea ModelIn many applications, it is a quite common practice to reduce the full model of the eyeball to a model of the cornea that is fixed at the limbus.5, 13, 47 However, such an approach significantly alters the results of the calculated optical power of the model because it significantly changes the location of the focal point with respect to the cornea. It also changes other optical functions of the eye that are important in biomechanical studies of the eyeball. The FEA solution for the fixed cornea model is similar to that of a model with a limbal ring that has infinitely high stiffness. However, two such models are not identical, because in the fixed corneal model the sclera expands. Figure 6 indicates that the optical mechanism of this model is different than that of the full model described earlier (see Fig. 4). The most important difference is in the shape of function . That is, unlike in the full model, the central anterior corneal radius of curvature decreases with an increase in . As a consequence, the focal distance in the fixed cornea model shortens and its amplitude gets larger than in the case of the full model. Also, the displacement of the focal point differs with changes in —it moves forward much more while previously it moved slightly backward. The reason for all of these differences between the two considered models is the dynamic behavior of the anterior corneal surface when it is fixed at the limbus (see Fig. 7 ). However, it is counterintuitive that these radically different boundary conditions lead also to a model that is optically self-adjusted in the range from [see function in Fig. 6]. It should be noted that it is not easy to achieve optical self-adjustment for the model. For the material , a deviation from criterion 7 and quickly puts the model “out of tune” in which function changes strongly in the whole range of considered pressures. 4.DiscussionWe have considered biomechanical models of a standard eyeball (surgically unaltered). The FEA solutions of the two considered models clearly indicate that the boundary conditions (in particular the way the cornea is fixed to the sclera) strongly influence the optics of the eyeball. The investigated case of the fixed cornea model is somewhat extreme. However, even for the model with the roller support of the cornea3, 13 at , it is not possible to achieve optical self-adjustment because this type of support does not fullfill condition 7. Thus, the most important feature of our proposed optically inspired model is its optical self-adjustment for intraocular pressure above . The principal condition for such behavior of the eye model is the constraint on the secant modulus of the sclera to be several times larger than that of the cornea. The Young’s modulus of the limbal ring, , also had to be chosen carefully. It is quite remarkable that these purely mechanical conditions were imposed simply by the optics. These modeling results have indicated that the increase of focal length , as well as the corresponding change in eye length , are functions of and are closely related for pressures above since their difference (equal to ) is almost constant. For example, for , the focal length changed by (from the clinically unseen in a real eye but biomechanically relevant case where ). If the length of the eye had not changed at the same time, one would expect that the focal point had moved by this value. However, in the optical self-adjustment model, the focus moved only by about , a difference of about (again, from the nominal point of ). Note that in a real eye, where the intraocular pressure may range between 10 and , the condition of optical self-adjustment results in changes of focal point that are not noticeable by a human. The solutions for the fixed cornea model (shown in Figs. 6 and 7 indicate that it is a drastically different model. The displacement of the second principal plane , despite originating mainly from the displacement of the crystalline lens [see Eq. 12], is much larger than in the full model. However, the largest difference can be seen in changes of the focal point with respect to the initial value of (for ). Not only has the change radically increased, but the sign also changed. Instead of moving by (backward), it moved by (forward). This leads to significant optical power changes: Thus, fixing the limbus results in a completely different optical model of the eyeball than in the case where the cornea is attached to the flexible sclera.The displacements of the limbus, although small, have a crucial impact on the optical power of the whole system being a function of the intraocular pressure . This functional relationship has an important role in the numerical studies of the eyeball. On the other hand, the displacements of the limbus caused by changes in depend on the material properties of both the sclera and the limbal ring. Therefore, it is important that these displacements are carefully considered in numerical models of the eyeball. AcknowledgmentsThe authors wish to thank Henryk Kasprzak for his encouragement, comments, and helpful suggestions. Part of this research was supported by the Australian Research Council 2007 Linkage Grant, LX0775988. ReferencesE. Uchio,
S. Ohno,
J. Kudoh,
K. Aoki, and
L. T. Kisielewicz,
“Simulation model of an eyeball based on finite element analysis on a supercomputer,”
Br. J. Ophthamol., 83 1106
–1111
(1999). 0007-1161 Google Scholar
H.-L. Yeh,
T. Huang, and
R. A. Schachar,
“A closed shell structured eyeball model with application to radial keratotomy,”
J. Biomech. Eng., 122
(5), 504
–510
(2000). https://doi.org/10.1115/1.1289626 0148-0731 Google Scholar
K. Anderson,
A. El-Sheikh, and
T. Newson,
“Application of structural analysis to the mechanical behaviour of the cornea,”
J. R. Soc., Interface, 1
(1), 3
–15
(2004). 1742-5689 Google Scholar
D. Cabrera Fernández,
A. M. Niazy,
R. M. Kurtz,
G. P. Djotyan, and
T. Juhasz,
“Finite element analysis applied to cornea reshaping,”
J. Biomed. Opt., 10
(6), 064018
(2005). https://doi.org/10.1117/1.2136149 1083-3668 Google Scholar
V. Alastrué,
B. Calvo,
E. Peña, and
M. Doblaré,
“Biomechanical modeling of refractive corneal surgery,”
J. Biomech. Eng., 128
(1), 150
–160
(2006). https://doi.org/10.1115/1.2132368 0148-0731 Google Scholar
P. R. Greene,
“Closed-form ametropic pressure-volume and ocular rigidity solutions,”
Am. J. Optom. Physiol. Opt., 62
(12), 870
–878
(1985). 0093-7002 Google Scholar
P. M. Pinsky,
D. van der Heide, and
D. Chernyak,
“Computational modeling of mechanical anisotropy in the cornea and sclera,”
J. Cataract Refractive Surg., 31
(1), 136
–145
(2005). 0886-3350 Google Scholar
T. J. Shin,
R. P. Vito,
L. W. Johnson, and
B. E. McCarey,
“The distribution of strain in the human cornea,”
J. Biomech., 30
(5), 497
–503
(1997). https://doi.org/10.1016/S0021-9290(97)84433-8 0021-9290 Google Scholar
S. L.-Y. Woo,
A. S. Kobayashi,
W. A. Schlegel, and
C. Lawrence,
“Nonlinear material properties of intact cornea and sclera,”
Exp. Eye Res., 14
(1), 29
–39
(1972). https://doi.org/10.1016/0014-4835(72)90139-X 0014-4835 Google Scholar
E. Sjøntoft and
C. Edmund,
“In vivo determination of Young’s modulus for the human cornea,”
Bull. Math. Biol., 49
(2), 217
–232
(1987). 0092-8240 Google Scholar
T. R. Friberg and
J. W. Lace,
“A comparison of the elastic properties of human choroid and sclera,”
Exp. Eye Res., 47 429
–436
(1988). https://doi.org/10.1016/0014-4835(88)90053-X 0014-4835 Google Scholar
J. Ø. Hjortdal,
“Regional elastic performance of the human cornea,”
J. Biomech., 29
(7), 931
–942
(1996). https://doi.org/10.1016/0021-9290(95)00152-2 0021-9290 Google Scholar
G. J. Orssengo and
D. C. Pye,
“Determination of the true intraocular pressure and modulus of elasticity of the human cornea,”
Bull. Math. Biol., 61
(3), 551
–572
(1999). 0092-8240 Google Scholar
C. Boote,
S. Dennis,
R. H. Newton,
H. Puri, and
K. M. Meek,
“Collagen fibrils appear more closely packed in the prepupillary cornea: optical and biomechanical implications,”
Invest. Ophthalmol. Visual Sci., 44
(7), 2941
–2948
(2003). https://doi.org/10.1167/iovs.03-0131 0146-0404 Google Scholar
A. J. Bellezza,
R. T. Hart, and
C. F. Burgoyne,
“The optic nerve head as a biomechanical structure: Initial finite element modeling,”
Invest. Ophthalmol. Visual Sci., 41
(10), 2991
–3000
(2000). 0146-0404 Google Scholar
M. Asejczyk-Widlicka,
D. W. Śródka,
H. Kasprzak, and
D. R. Iskander,
“Influence of intraocular pressure on geometrical properties of a linear model of the eyeball: Effect of optical self-adjustment,”
Optik (Stuttgart), 115
(11), 517
–524
(2004). 0030-4026 Google Scholar
H. Kasprzak,
“A model of inhomogeneous expansion of the cornea and stability of its focus,”
Ophthalmic Physiol. Opt., 17 133
–136
(1997). 0275-5408 Google Scholar
T. N. Wiesel and
E. Raviola,
“Myopia and eye enlargement after neonatal lid fusion in monkeys,”
Nature (London), 266 66
–68
(1977). 0028-0836 Google Scholar
F. Schaeffel,
A. Glasser, and
H. C. Howland,
“Accommodation, refractive error and eye growth in chickens,”
Vision Res., 28
(5), 639
–657
(1988). https://doi.org/10.1016/0042-6989(88)90113-7 0042-6989 Google Scholar
C. Edmund,
“Posterior corneal curvature and its influence on corneal dioptric power,”
Acta Ophthalmol., 72
(6), 715
–720
(1994). 0001-639X Google Scholar
S. Patel,
J. Marshall, F. W. Fitzke III,
“Refractive index of the human corneal epithelium and stroma,”
J. Refract. Surg., 11
(2), 100
–105
(1995). 1081-597X Google Scholar
Z. Liu,
A. J. Huang, and
S. C. Pflugfelder,
“Evaluation of corneal thickness and topography in normal eyes using the Orbscan corneal topography system,”
Br. J. Ophthamol., 83
(7), 774
–778
(1999). 0007-1161 Google Scholar
T. Eysteinsson,
F. Jonasson,
H. Sasaki,
A. Arnarsson,
T. Sverrisson,
K. Sasaki,
E. Stefánsson, Reykjavik Eye Study Group,
“Central corneal thickness, radius of the corneal curvature and intraocular pressure in normal subjects using non-contact techniques: Reykjavik eye study,”
Acta Ophthalmol. Scand., 80
(1), 11
–15
(2002). 1395-3907 Google Scholar
E. Rusinski,
(1994) Google Scholar
C. W. McMonnies and
G. C. Boneham,
“Experimentally increased intraocular pressure using digital forces,”
Eye Contact Lens, 33
(3), 124
–129
(2007). Google Scholar
C. W. McMonnies and
G. C. Boneham,
“Corneal curvature stability with increased intraocular pressure,”
Eye Contact Lens, 33
(3), 130
–137
(2007). Google Scholar
Y. Le Grand and
S. G. El Hage, Physiological Optics, 13 Springer-Verlag, Berlin-Heidelberg-New York
(1980). Google Scholar
P. M. Kiely,
G. Smith, and
L. G. Carney,
“The mean shape of the human cornea,”
Opt. Acta, 29
(8), 1027
–1040
(1982). 0030-3909 Google Scholar
M. Dubbelman,
H. A. Weeber,
R. G. L. van der Heijde, and
H. J. Völker-Dieben,
“Radius and asphericity of the posterior corneal surface determined by corrected Scheimpflug photography,”
Acta Ophthalmol. Scand., 80 379
–383
(2002). https://doi.org/10.1034/j.1600-0420.2002.800406.x 1395-3907 Google Scholar
M. Baumeister,
E. Terzi,
Y. Ekici, and
T. Kohnen,
“Comparison of manual and automated methods to determine horizontal corneal diameter,”
J. Cataract Refractive Surg., 30
(8), 374
–380
(2004). 0886-3350 Google Scholar
W. Lotmar,
“Theoretical eye model with aspherics,”
J. Opt. Soc. Am., 61 1522
–1529
(1971). 0030-3941 Google Scholar
H. L. Liou and
N. A. Brennan,
“Anatomically accurate, finite model eye for optical modeling,”
J. Opt. Soc. Am. A, 14
(8), 1684
–1695
(1997). https://doi.org/10.1364/JOSAA.14.001684 0740-3232 Google Scholar
T. Raphan,
“Modeling control of eye orientation in three dimensions. I. Role of muscle pulleys in determining saccadic trajectory,”
J. Neurophysiol., 79 2653
–2667
(1998). 0022-3077 Google Scholar
T. Haslwanter,
“Mechanics of eye movements: implications of the “orbital revolution,”
Ann. N.Y. Acad. Sci., 956 33
–41
(2002). 0077-8923 Google Scholar
J. L. Demer,
“Ocular kinematics, vergence, and orbital mechanics,”
Strabismus, 11
(1), 49
–57
(2003). Google Scholar
S. Schutte,
S. P. van den Bedem,
F. van Keulen,
F. C. T. van der Helm, and
H. J. Simonsz,
“A finite-element analysis model of orbital biomechanics,”
Vision Res., 46 1724
–1731
(2006). 0042-6989 Google Scholar
A. Pandolfi and
F. Manganiello,
“A model for the human cornea: constitutive formulation and numerical analysis,”
Biomech. Model. in Mechanobiol., 5
(4), 237
–246
(2006). Google Scholar
I. G. Pallikaris,
G. D. Kymionis,
H. S. Ginis,
G. A. Kounis, and
M. K. Tsilimbaris,
“Ocular rigidity in living human eyes,”
Invest. Ophthalmol. Visual Sci., 46
(2), 409
–414
(2005). 0146-0404 Google Scholar
Y. C. Fung, Biomechanics: Mechanical Properties of Living Tissues, Springer-Verlag, NY
(1993). Google Scholar
B. Jue and
D. M. Maurice,
“The mechanical properties of the rabbit and human cornea,”
J. Biomech., 19
(10), 847
–53
(1986). https://doi.org/10.1016/0021-9290(86)90135-1 0021-9290 Google Scholar
L. S. Nash,
P. R. Greene, and
C. S. Foster,
“Comparison of mechanical properties of keratoconus and normal corneas,”
Exp. Eye Res., 35 413
–423
(1982). 0014-4835 Google Scholar
M. R. Bryant and
P. J. McDonnell,
“Constitutive laws for biomechanical modelling of refractive surgery,”
J. Biomech. Eng., 118
(4), 473
–481
(1996). https://doi.org/10.1115/1.2796033 0148-0731 Google Scholar
S. L. Woo,
A. S. Kobayashi,
C. Lawrence, W. A. Schlegel,
“Mathematical model of the corneo-scleral shell as applied to intraocular pressure-volume relations and applanation tonometry,”
Ann. Biomed. Eng., 1
(1), 87
–98
(1972). 0090-6964 Google Scholar
J. Liu and
C. J. Robert,
“Influence of corneal biomechanical properties on intraocular pressure measurement,”
J. Cataract Refractive Surg., 31 146
–155
(2005). 0886-3350 Google Scholar
J. L. Battaglioli and
R. D. Kamm,
“Measurements of the compressive properties of scleral tissue,”
Invest. Ophthalmol. Visual Sci., 25
(1), 59
–65
(1984). 0146-0404 Google Scholar
H. Goldmann and
T. Schmidt,
“Applanation tonometry,”
Ophthalmologica, 134
(4), 221
–242
(1957). 0030-3755 Google Scholar
S. Shah,
“Accurate intraocular pressure measurement—the myth of modern ophthalmology,”
Ophthalmology (Philadelphia), 107
(10), 1805
–1807
(2000). 0161-6420 Google Scholar
R. P. Mills,
“If intraocular pressure measurement is only an estimate—then what,”
Ophthalmology (Philadelphia), 107
(10), 1807
–1808
(2000). 0161-6420 Google Scholar
M. Asejczyk-Widlicka,
D. W. Śródka,
H. Kasprzak, and
B. K. Pierscionek,
“Modelling the elastic properties of the anterior eye and their contribution to maintenance of image quality: the role of the limbus,”
Eye, 21
(8), 1087
–1094
(2007). 0950-222X Google Scholar
J. S. Friedenwald,
“Contribution to the theory and practice of tonometry,”
Am. J. Ophthalmol., 20 985
–1024
(1937). 0002-9394 Google Scholar
|