1.IntroductionSkin cancer cells are known to produce a highly fluorescent porphyrin called protoporphyrin IX (PpIX), when aminolevulinic acid (ALA) is applied,1, 2, 3 and its use is approved for photodynamic treatment of superficial forms of squamous cell carcinoma (SCC) and basal cell carcinoma (BCC). For thicker skin carcinomas, a major concern has been the inability to measure the amount of PpIX production that is occurring at deep tumor locations. Adjuvant methods to stimulate PpIX could work, such as differentiation therapy,4 and better tools are needed to assess if enhanced PpIX production is obtained in individual subjects. The goal of the current study is to develop and test a system that can quantify PpIX concentrations in skin tumor tissue by directly measuring the signal emitted from the tissue surface, while simultaneously quantifying the tumor margin with high frequency ultrasound (HFUS). Preclinical development and testing of this device was the subject of this study, with full calibration, tissue phantom testing, and a pilot study in a preclinical model. This approach to guide the interpretation of the fluorescence signal5, 6, 7 is beneficial because subsurface tomography with light is quite challenging. Subsurface diffuse optical tomography without any additional imaging is known to be inaccurate8, 9 because of the ill-posed numerical inversion problem. High scatter and absorption attenuation contribute to a nonlinear relationship between detected signal and PpIX concentration. Image-guided fluorescence tomography10 with HFUS should allow characterization of skin layers and tumor PpIX concentrations. Hybrid ultrasound/optical imaging was demonstrated by other researchers, most notably substantial developments in breast tumor imaging by Zhu 11 In this work, the hardware and software12 were designed for automated calibration and were tested in phantoms, along with an initial preclinical demonstration. 2.Materials and MethodsThe system [schematic in Fig. 1 ] has been assembled from low-cost, commercially available products and specifically designed to be as portable and modular as possible. There are four source and five detection channels that are automated through computer control. The lasers in the four-source module (ThorLabs, Newton, New Jersey, model MCSL635) are centered at wavelength at power. Laser outputs couple into fibers, and intensities are electronically controlled from LabView controlled data acquisition (DAQ) cards (National Instruments, Austin, Texas, model USB 6009). All four sources were stable to within 0.5 to 4% over a time period of , and repeatable to within 1 to 4% for successive system starts. In detection, five compact USB-coupled spectrometers (Ocean Optics, Dunedin, Florida, model USB2000+) are used for each fiber, with a wavelength resolution of and spectral bandwidth of . An inline filter holder (OceanOptics, model FHS-UV) with a long pass filter (ThorLabs, FEL0650) is used to remove the source signals while allowing passage of the PpIX fluorescence, peaked at wavelength. Source and detector fibers alternate linearly along the length of the tissue contact probe [Fig 1] just adjacent to the ultrasound probe. The holder protects the fibers while also immobilizing them above gradient index (GRIN) lenses (Newport Corporation, Irvine, California, model LGI630-6), that focus them below the probe surface, matching the height of the clear gel coupling the ultrasound system to the tissue surface. Ultrasound imaging was conducted with a Vevo 770 (VisualSonics, Toronto, Ontario) using either an RMV-708 ( maximum frequency; axial and lateral resolution with field of view) or a RMV-704 ( maximum frequency; axial and lateral resolution with field of view) scan head. For in-vivo imaging, mice were anesthetized with about 2.5% isoflurane initially and reduced to 1.5% during imaging, and were positioned on a thermoregulated platform. The scan head/optical detector complex was held in place during imaging acquisition. An ultrasound snapshot was taken in the tumor plane, and then the sample is moved until it is in the plane of the optical sources and detectors. The software acquires background levels and sequenced each of the four lasers while capturing all five detector spectra. The signal in the spectrum that was not part of the PpIX peak was due to broadening of the laser source and autofluorescence. The data are automatically calibrated for individual response, and autofluroescence is removed. Simulations were done to validate the accuracy of our system’s measurements using the finite element-based NIRFast Matlab software.8 System validation was performed using heterogeneous tissue phantoms using 1% Intralipid™ for scattering and 0.002% India ink for absorption,13 with 5% Tween-20 to monomerize the PpIX. This was mixed with 1% agarose (Sigma Aldrich, Saint Louis, Missouri) in water heated to the boiling point, and then cooled at for to create solid fluorescent phantoms. Imaging of two-layer gelatin phantoms was performed with the PpIX concentration of the bottom layer fixed at , and the top layer varied from . The reverse case was also imaged—holding the top layer constant at and varying the bottom layer from . 3.ResultsThe results of all two-layer phantom experiments are displayed in Figs. 1 and 1. Interestingly, the recovery of fluorescence yield is always perfectly accurate in the layer that has the higher fluorescence. Yet in both the lower and upper layers, when the fluorescence is lower than the opposite layer, the recovery is not fully accurate. This figure shows the experimental validation of the system in a controlled manner. As might be expected, when the fluorescence is very low, there is a higher fluorescence recovered, because the signal from the opposite layer is presumably causing some overestimation of the lower region. Figure 2 demonstrates the ability of the system to give reasonable reconstructed images for three-layer gelatin phantoms. For these experiments, a thin layer of gelatin with PpIX was placed over a bump of gelatin with a different concentration of PpIX. The bump sizes were . The bottom layer consisted of gelatin with no PpIX fluorescence. This accurately simulated the situation seen when imaging subcutaneous tumors in mice. The top layers of the image were segmented, and a Matlab routine created the finite element meshes in Fig. 2.14 Each region of the mesh was assumed to be homogeneous in fitting for fluorescence in the tissue types. Figure 2 shows recovery of a simulated tumor region with higher fluorescence than the skin, and Fig. 2 shows recovery when the simulated tumor region was lower than the skin. All procedures using animals were approved by the Institutional Animal Care and Use Committee. The rat U251 gliosarcoma cells were implanted in phosphate buffered saline (PBS) at with into the nude mice skin and grown for a -diam tumor. Tumors were imaged after ALA injection prior. Figure 2 shows a typical result for a subcutaneous tumor in a mouse. Mouse skin is highly fluorescent compared to the tumor, as expected. These results were verified with ex-vivo fluorescence scanning of the tissues (GE Healthcare Typhoon) to validate the images. These images indicate that the skin contains nearly four times the fluorescence found in U251 tumors [Fig. 2]. The shape of the tumor matches exactly the shape of the fluorescent overlay, since the ultrasound image was used to guide the solution. 4.DiscussionAccurate quantification of PpIX production in skin tumors remains an ongoing challenge. PpIX production and treatment efficacy are unclear for deeper tumors, yet methods to enhance production are available. High-frequency ultrasound provides a clear structural image that allows us to combine anatomical information with fluorescence data for reconstruction algorithms. In creation of an ultrasound-guided fluorescence recovery system, the system integration was straightforward and modular, and phantom testing provided a way to validate the system. The problem of subsurface tomography is known to be confounded when there is an upper layer that is significantly more fluorescent than the lower layer. Intuitively, it is possible to realize that as the upper layer fluorescence level increases, eventually the lower layer signal will be lost in the noise of the detection system as the upper layer dominates the detected signal. As such, there will always be a lower limit, below which the lower fluorescence layer cannot be effectively quantified or even detected with decreasing depth or with decreasing contrast. In the experimental case here, when the tumors have lower PpIX production than the overlying skin, and as shown in Fig. 2, the more fluorescent layer of the skin tends to dominate the reconstruction algorithm. The simulations and phantom data indicate that the system has a sufficiently good signal-to-noise region to recover tumor fluorescence images down to several millimeters depth, but the lower layer is most inaccurate due to confounding information in the upper layer. The image segmentation still must be user-guided to avoid errors from the speckle and noise in the ultrasound images, but the segmentation process of region growing works well with just seconds of user guidance. 5.ConclusionsA system development study creating the first high-frequency ultrasound-guided fluorescence tomography system is initiated for imaging skin tumors. Simulations and phantoms studies show that the system works well. Phantom results demonstrate the ability to determine fluorescence in multilayer situations mimicking skin tumors, and initial in-vivo imaging is promising. Preclinical studies are ongoing to analyze the system performance with various shapes, sizes, depths, PpIX concentrations, and to improve the recovered contrast values. AcknowledgmentsThe authors are extremely grateful to Subhadra Srinivasan, Hamid Dehghani, and Keith Paulsen for productive discussions about the algorithm development. This work has been funded by NIH Program Project P01CA84203. ReferencesJ. Kennedy,
“Endogenous protoporphyrin IX, a clinically useful photosensitizer for photodynamic therapy,”
J. Photochem. Photobiol., 14
(4), 275
–292
(1992). https://doi.org/10.1016/1011-1344(92)85108-7 Google Scholar
Z. Hua,
S. L. Gibson,
T. H. Foster, and
R. Hilf,
“Effectiveness of {delta}-aminolevulinic acid-induced protoporphyrin as a photosensitizer for photodynamic therapy in vivo,”
Cancer Res., 55
(8), 1723
–1731
(1995). 0008-5472 Google Scholar
Z. Malik,
G. Kostenich,
L. Roitman,
B. Ehrenberg, and
A. Orenstein,
“Topical application of 5-aminolevulinic acid, DMSO and EDTA: protoporphyrin IX accumulation in skin and tumours of mice,”
J. Photochem. Photobiol., B, 28
(3), 213
–218
(1995). https://doi.org/10.1016/1011-1344(95)07117-K 1011-1344 Google Scholar
B. Ortel,
N. Chen,
J. Brissette,
G. P. Dotto,
E. Maytin, and
T. Hasan,
“Differentiation-specific increase in ALA-induced protoporphyrin IX accumulation in primary mouse keratinocytes,”
Br. J. Cancer, 77
(11), 1744
–1751
(1998). 0007-0920 Google Scholar
Q. Zhu,
N. G. Chen,
D. Piao,
P. Guo, and
X. Ding,
“Design of near-infrared imaging probe with the assistance of ultrasound localization,”
Appl. Opt., 40
(19), 3288
–3303
(2001). https://doi.org/10.1364/AO.40.003288 0003-6935 Google Scholar
Q. Zhu,
S. H. Kurtzma,
P. Hegde,
S. Tannenbaum,
M. Kane,
M. Huang,
N. G. Chen,
B. Jagjivan, and
K. Zarfos,
“Utilizing optical tomography with ultrasound localization to image heterogeneous hemoglobin distribution in large breast cancers,”
Neoplasia, 7
(3), 263
–270
(2005). https://doi.org/10.1593/neo.04526 1522-8002 Google Scholar
C. M. Carpenter,
B. W. Pogue,
S. Jiang,
H. Dehghani,
X. Wang,
K. D. Paulsen,
W. A. Wells,
J. Forero,
C. Kogel,
J. B. Weaver,
S. P. Poplack, and
P. A. Kaufman,
“Image-guided optical spectroscopy provides molecular-specific information in vivo: MRI-guided spectroscopy of breast cancer hemoglobin, water, and scatterer size,”
Opt. Lett., 32
(8), 933
–935
(2007). https://doi.org/10.1364/OL.32.000933 0146-9592 Google Scholar
D. S. Kepshire,
S. C. Davis,
H. Dehghani,
K. D. Paulsen, and
B. W. Pogue,
“Subsurface diffuse optical tomography can localize absorber and fluorescent objects but recovered image sensitivity is nonlinear with depth,”
Appl. Opt., 46
(10), 1669
–1678
(2007). https://doi.org/10.1364/AO.46.001669 0003-6935 Google Scholar
D. Kepshire,
S. C. Davis,
H. Dehghani,
K. D. Paulsen, and
B. W. Pogue,
“Fluorescence tomography characterization for sub-surface imaging with protoporphyrin IX,”
Opt. Express, 16
(12), 8581
–8593
(2008). https://doi.org/10.1364/OE.16.008581 1094-4087 Google Scholar
S. C. Davis,
H. Dehghani,
J. Wang,
S. Jiang,
B. W. Pogue, and
K. D. Paulsen,
“Image guided diffuse optical fluorescence tomography implemented with Laplacian-type regularization,”
Opt. Express, 15
(7), 4066
–4082
(2007). https://doi.org/10.1364/OE.15.004066 1094-4087 Google Scholar
Q. Zhu,
T. Durduran,
V. Ntziachristos,
M. Holboke, and
A. G. Yodh,
“Imager that combines near-infrared diffusive light and ultrasound,”
Opt. Lett., 24
(15), 1050
–1052
(1999). https://doi.org/10.1364/OL.24.001050 0146-9592 Google Scholar
H. Dehghani,
M. E. Eames,
P. K. Yalavarthy,
S. C. Davis,
S. Srinivasan,
C. M. Carpenter,
B. W. Pogue, and
K. D. Paulsen,
“Near infrared optical tomography using NIRFAST: algorithm for numerical model and image reconstruction,”
Commun. Numer. Methods Eng.,
(2008)
(1069-8299) Google Scholar
B. W. Pogue and
M. S. Patterson,
“Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry,”
J. Biomed. Opt., 11
(4), 041102
(2006). https://doi.org/10.1117/1.2335429 1083-3668 Google Scholar
H. Ghadyani,
J. Sullivan, and
Z. Wu,
“Boundary recovery for Delaunay tetrahedral meshes using local topological transformations,”
Finite Elem. Anal. Design, 46
(1–2), 74
–83
(2010). https://doi.org/10.1016/j.finel.2009.06.022 0168-874X Google Scholar
|