Open Access
1 September 2011 Color stability of maxillofacial silicone with nanoparticle pigment and opacifier submitted to disinfection and artificial aging
Marcela Filie Haddad, Marcelo Coelho Goiato, Daniela Micheline dos Santos, Amalia Moreno, Aldieris Alves Pesqueira, Nuno Filipe D'almeida
Author Affiliations +
Abstract
The purpose of this study was to evaluate the color stability of a maxillofacial elastomer with the addition of a nanoparticle pigment and/or an opacifier submitted to chemical disinfection and artificial aging. Specimens were divided into four groups (n = 30): group I: silicone without pigment or opacifier, group II: ceramic powder pigment, group III: Barium sulfate (BaSO4) opacifier, and group IV: ceramic powder and BaSO4 opacifier. Specimens of each group (n = 10) were disinfected with effervescent tablets, neutral soap, or 4% chlorhexidine gluconate. Disinfection was done three times a week during two months. Afterward, specimens were submitted to different periods of artificial aging. Color evaluation was initially done, after 60 days (disinfection period) and after 252, 504, and 1008 h of artificial aging with aid of a reflection spectrophotometer. Data were analyzed by three-way ANOVA and Tukey test (α = 0.05). The isolated factor disinfection did not statistically influence the values of color stability among groups. The association between pigment and BaSO4 opacifier (GIV) was more stable in relationship to color change (△E). All values of △E obtained, independent of the disinfectant and the period of artificial aging, were considered acceptable in agreement with the norms presented in literature.

1.

Introduction

The prosthetic rehabilitation of facial defects has, as an objective, the aesthetic restoration and reestablishment of self-esteem of mutilated patients.1, 2, 3, 4 Color is the most important parameter used by patients in the evaluation of facial prostheses.1, 5, 6, 7, 8, 9 Color change is one of the needs of substitution, which unfortunately occurs in a short period of time.5, 9, 10, 11, 12, 13

Silicone prostheses are considered color effective for about six months up to one year, and afterward must be redone.4, 9, 10, 12 The instability of observed color is attributed to the constant exposition to ultraviolet (UV) light, air pollution, pigment additions, 3, 4, 13, 14, 15, 16, 17, 18, 19 and the use of cleansing products.9, 11, 20, 21

Literature has shown that intrinsic addition of opacifiers to facial silicones promoted longer color maintenance.17, 18, 19 Among the opacifiers commercially available, Barium sulfate (BaSO4) is mentioned. It consists in a white powder, insoluble in water and organic fluids, used in the industry to achieve the white color in paints, glass, and photographic papers. In dentistry, it is used as an opacifier of endodontic cements22, 23 and in medicine as radiographic contrast. It is also added to sunscreens due to the physical capacity of UV shielding24, 25 and to obtain an enhanced appearance in cosmetics.26 However, literature is scarce about the interrelation of opacifier addition to facial silicones, mainly when the material is submitted to the process of chemical disinfection and artificial aging.

The present study had the purpose to verify color stability of Silastic MDX4-4210 facial silicone alone, with the addition of ceramic nanoparticles associated or not to a BaSO4 opacifier submitted to several chemical disinfection procedures and latter submitted to artificial aging.

The null hypotheses were that the studied factors have no significant influence over the values of specimen color changes.

2.

Materials and Methods

Specimens were made using a metallic cylindrical flask, with 10 cavities with a diameter of 30 mm and 6 mm in height.5, 16, 27, 28 The silicone Silastic MDX4-4210 Silicone (Dow Corning Corporation, Midland, Michigan) was handled in agreement with the manufacturer's instructions, at a controlled room temperature 23 + 2°C and relative humidity of 50 + 10%. One hundred twenty specimens were made, and according to the experimental condition, divided into four groups of 30 specimens each, named as GI: Plain silicone – no pigment or opacifier; GII: silicone pigmented with ceramic powder (Clarart, Brasília, DF, Brazil); GIII: silicone with the addition of BaSO4 (Wako, Osaka, Japan); GIV: silicone pigmented with ceramic powder and the addition of BaSO4.

For groups that received the addition of nanoparticle pigments and/or opacifier (GII, GIII, and GIV), pigments were weighed with a precision digital scale, equivalent to 0.2% by weight3, 4, 16, 29 of the necessary silicone to fill up the space of the metallic flask. Each pigment was mixed into the silicone on a glass plate with the aid of a stainless steel spatula to obtain a homogeneous mixture.3, 4, 16

All silicone combinations were inserted inside the flask and leveled on the surface with a metal spatula to maintain the uniform thickness. Each silicone combination was confined inside the flask with the external surface exposed to the environment for 72 h. After that period, each specimen was carefully separated from the metallic flask.3, 4, 5, 27, 28

Initial color for all specimens was registered. All color values were obtained using a UV reflection spectrophotometer (Model UV-2450, Shimadzu, Kyoto, Japan), according to the previously described method,4, 5, 16, 17, 18, 19 with the color changes calculated by means of the CIE L*a*b* system.30 The “L” axis is known as brightness and extends from 0 (black) to 100 (perfect white). The coordinate “a” represents the amount of red (positive values) and of green (negative values), while the coordinate “b” represents the amount of yellow (positive values) and of blue (negative values). This system calculates the value of E (color change), between two readings, by means of the formula:

[TeX:] \documentclass[12pt]{minimal}\begin{document}\begin{equation*} \Delta {\rm E = [(}\Delta {\rm L)}^{\rm 2} {\rm + (}\Delta {\rm a)}^{\rm 2} {\rm + (}\Delta {\rm b)}^{\rm 2} {\rm]}^{{\rm 1/2}} {\rm.} \end{equation*}\end{document} ΔE=[(ΔL)2+(Δa)2+(Δb)2]1/2.
Ten specimens of each group were disinfected with one of the following substances: Efferdent alkaline peroxide effervescent (Ef) tablets (Pfizer Consumer Healthcare, Morris Plains, New Jersey),5, 27, 28 neutral soap (Ns) (Johnson & Johnson, São José dos Campos, SP, Brazil),5, 27, 28 and 4% solution of chlorhexidine (Cl) (Naturativa, Araçatuba, SP, Brazil).31, 32

The process of chemical disinfection was accomplished three times a week for 60 days.5, 27, 28, 32 For disinfection with Efferdent, specimens were immersed for 15 min in a container containing an effervescent tablet dissolved in 250 mL of warm water with an initial temperature of 37°C and afterward rinsed in running water.5, 27, 28 Specimens washed with neutral soap were thoroughly scrubbed with it by hand friction for 30 s and rinsed in running water.32 Specimens disinfected with chlorhexidine were immersed in the solution for 10 min and rinsed in running water.31 After each disinfection procedure, all specimens were stored in a lightproof black box (no incidence of natural or artificial light), with controlled conditions of temperature (23 ± 2°C) and relative humidity (50 ± 10%), to avoid the occurrence of possible color changes.3, 4, 16

After the 60-day disinfection period, new color readings were accomplished and specimens were subsequently submitted to an artificial aging process for nonmetallic bodies (Ultraviolet B/condensation – ASTM).33 For the artificial aging, specimens were positioned in the artificial aging chamber (Equilam, Diadem, SP, Brazil) and submitted to alternated periods of ultraviolet light and darkness with condensation of distilled water saturated in oxygen. Each aging cycle was accomplished in 12 h. In the first 8 h, ultraviolet light irradiance was at a temperature of 60 ± 3°C. In the following 4 h, a dark condensation period was at a temperature of 45 ± 3°C. In this way, 1008 artificial aging hours were accomplished simulating deterioration caused by rain, dew, and UV light (both direct and indirect sunlight irradiance). Specimens were removed for more color readings in the intervals 252, 504, and final 1008 h of artificial aging,3, 4, 16 totaling five readings.

The values of color change (E) were submitted to the variance analysis (ANOVA) for three factors, followed by the Tukey test (p < 0.05).

3.

Results

Obtained results are shown in Tables 1, 2. Considering the pigment, regardless of disinfectant and period, the analysis of variance (ANOVA) reveled a statistically significant difference (P < 0.0001) (Table 1). Additionally, the period statistically affected the color alteration of the samples (P < 0.001; ANOVA). No difference in color change was noted among the disinfectants regardless of pigment and period (P > 0.05; ANOVA). The interaction among period, disinfectant, and pigment was statistically significant (P < 0.001; ANOVA) (Table 1). All the studied factors, when associated, significantly influenced the values of △E of the specimens.

Table 1

Results of three-way repeated-measures ANOVA. [*P < 0.05 denotes statistically significant difference.]

SourcedfSSMSFP
Disinfectant20.1180.0590.8510.430
Pigment324.4558.152117.648<0.0001*
Disinfectant × pigment618.3753.06344.200<0.0001*
Between subjects1087.4830.069
Period317.2425.747118.892<0.0001*
Period × Disinfectant61.1530.1923.9740.001*
Period × Pigment95.0870.56511.692<0.0001*
Period × Disinfectant × Pigment1817.9460.99720.625<0.0001*
Within subjects32415.6630.048

Table 2

Mean values (SD) of △E for Silastic in the groups with different chemical disinfections. [Ns = Neutral soap; Ef = efferdent evervescent tablets; Cl = 4% clorexidine. Averages followed by the same capital letter in the column and for the same letter in lower case in the line did not significantly differ (p <0.05).]

Groups
PeriodDisinfectantGIGIIGIIIGIV
60 daysNs1.07 (0.23) Aa1.26 (0.18) Aa0.43 (0.13) Ab0.25 (0.08) Ab
Ef0.55 (0.10) Ba1.21 (0.12) Ab1.22 (0.10) Bb0.33 (0.13) Aa
Cl1.14 (0.22) Aa0.77 (0.17) Bab0.93 (0.29) Bab0.53 (0.17) Ab
252 hNs2.04 (0.33) Aa1.69 (0.27) Aa0.65 (0.21) Ab0.45 (0.11) Ab
Ef1.39 (0.11) Ba1.22 (0.26) Ba1.29 (0.24) Ba1.00 (0.23) Ba
Cl0.99 (0.26) Ba0.81 (0.15) Ba1.74 (0.32) Cb1.16 (0.17) Ba
504 hNs1.97 (0.23) Aa0.94 (0.17) Ab1.12 (0.23) ABb0.93 (0.24) Ab
Ef1.41 (0.30) Ba1.38 (0.23) Ba0.91 (0.20) Ab0.74 (0.21) Ab
Cl1.17 (0.22) Bab0.93 (0.25) Ab1.45 (0.32) Ba1.13 (0.25) Aab
1008 hNs2.07 (0.49) Aa0.76 (0.19) Ab1.27 (0.29) Ac0.71 (0.11) Ab
Ef1.57 (0.24) Ba1.50 (0.28) Ba1.36 (0.27) Aab1.08 (0.27) Ab
Cl1.63 (0.23) Ba1.39 (0.34) Bab1.30 (0.16) Aab1.07 (0.14) Ab

In Table 2, E values are shown for each group in the several experimental periods for each disinfectant type. Group GI (soap disinfection) showed the highest color change for all experimental periods. For group GII (chlorhexidine disinfection), specimens presented the lowest values of E among all other periods, except for 1008 h of artificial aging. For groups GIII and GIV, specimens submitted to soap disinfection showed the lowest color change in comparison to others in all of the experimental periods, except for 504 h of artificial aging.

4.

Discussion

Prostheses made with silicones are considered effective for six months up to one year, having the need of substitution due to color instability, deterioration of the texture, and margins and decrease of resistance. This occurs in function of the effects of ultraviolet rays, deposition of microscopic residues on surface porosities, use of skin adhesives, by continuous patient handling and cleansing. 4, 5, 6, 8, 9, 10, 12, 14, 17, 27, 28, 34

The results of this study support rejection of the null hypotheses. In Table 1, when the studied factors (disinfection, pigment, and period) were associated, color changes were seen in specimens.

In Table 2, when comparing the values of E of each group in the different experimental periods, specimens of group GI disinfected with neutral soap exhibited the highest color change for all of the experimental periods.

In the present study, neutral soap (chemically inert) was considered as a control disinfection product.5 The disinfection of specimens with this product is done through digital friction, what is considered a negative point; because this technique can remove nanoparticles (pigments) on the superficial layer of the material. This fact can justify the highest color change presented in specimens of groups GI and GII after 60 days of disinfection with neutral soap (Table 2).

As seen in Table 1, disinfection alone did not significantly influence the value of E. It can be assumed that the color change presented by group GI (Table 2) is a consequence of a small but continuous liberation of by-products during the silicone polymerization seen after 60 days of disinfection and during the different periods of artificial aging.5 This could cause not only the dimensional change of silicone (contraction) but also changes in its chromatic pattern. The amount of each one of those factors, as well as the different types of solar irradiation, different degrees of humidity, and temperature variations, have an effect on these materials.5, 11

However, when the BaSO4 is added to specimens (groups GIII and GIV), the color change is lower than specimens disinfected with other substances (Table 2).

Physical sunshields, as Barium sulfate (BaSO4), Titanium dioxide (TiO2), and Zinc oxide (ZnO) present the advantages of safety, effectiveness, and blockage of ultraviolet rays. Due to their capacity of solar light reflectance and dispersion, in function of the size of their particles and their film thickness formed on the skin.24, 25, 35

Opacifiers consist of inorganic particles that remain in suspension when incorporated in sunscreen formulas. The size of these particles is extremely important for solar blockage effectiveness of the suntan lotion and for the aesthetic appearance of the cosmetic product.26 As BaSO4 is composed by nanoparticles, it has the capacity to accomplish strong union to the polymeric chain of the silicone.16, 36 This also occurs when it is associated to ceramic pigments avoiding pigment removal through the repeated execution of the disinfection technique with neutral soap for 60 days.

In Table 2, group GII presents a significant reduction of color change after 504 and 1008 h of aging when compared to the changes shown after 60 days of disinfection with soap and after 252 h of artificial aging.

In the first moment, it seemed that specimens returned to the initial color have a tendency for color stabilization on part of the ceramic. In that case, it can be thought that during the aging period of 252 h, nanoparticle pigments not united to the polymeric molecular chain suffered oxidation by the action of UV light,16, 34 leaving the color of the material more unstable. In 1008 h, those nanoparticles were removed by the action of the artificial aging and the polymeric organic matrix began degradation, which disguised the results.16

Group GIV was the most stable for all of the aging periods when disinfected with neutral soap (Table 2). Once again, this proves that the association of opacifier and pigment favors their connection to the silicone polymer, without their removal during disinfection and also protects the material of degradation promoted by the exposure to UV rays of the artificial aging chamber.24, 25, 26, 35

In group GII, specimens disinfected with 4% chlorhexidine presented the lowest E values for all artificial aging periods, except for 1008 h.

The 4% chlorhexidine solution is biocompatible and the immersion disinfection technique is considered the most favorable in treating facial silicone prostheses.9 The lowest significant values of E presented by the different groups disinfected with chlorhexidine (Table 2), was noticed for group GIV after 60 days of disinfection with chlorhexidine and 1008 h of artificial aging. These values were even lower when compared to group GI and reinforce the concept that the association of ceramic nanoparticles and BaSO4 opacifier hinder their removal by the repeated chemical disinfection process and protects the silicone and the ceramic powder of deterioration promoted by artificial aging.

Specimens with BaSO4 addition and disinfected for 60 days with chlorhexidine presented E values statistically higher after 252 h of artificial aging when compared to other disinfection periods, but this change was not significant after 1008 h (Table 2).

When the different disinfectants are compared for each group (Table 2), it can be seen for group GI that those specimens disinfected with Efferdent presented the lowest value of E, which indicates a silicone polymeric matrix degradation that occurred independently of the nanoparticle addition. Group GIII specimens disinfected with neutral soap exhibited the lowest E values after 60 days of disinfection, sustaining the hypothesis that the BaSO4 opacifier constituted by nanoparticles accomplishing a strong union with the silicone polymeric matrix16, 26 were not removed by digital friction. After 1008 h of aging, group GII statistically presented a significant difference when disinfected with neutral soap.

The Efferdent effervescent tablets are alkaline peroxides, which can be used for cleaning both intra- and extra-oral prostheses.5, 37 This product basically acts by means of oxygen liberation, with the objective of loosening fragments and removing light stains.5 By this method, it is reasonable to think that the oxygen-based cleansers, although they remove small stains, also cause prostheses whitening as already cited in other studies.5, 37 In group GI, the color change presented by specimens after 60 days of disinfection with Efferdent was significantly lower than specimens submitted by other disinfection methods (Table 2).

The low change observed for group GI specimens when disinfected with Efferdent is more specifically due to the composition of the silicone, originally clear without color,28 not presenting, therefore pigment degradation with the continuous procedure of disinfection.

After the artificial aging periods, there was no statistically significant difference among values of E among specimens of group GI disinfected with Efferdent and with Chlorhexidine. However, these values were significantly lower than the values obtained for specimens disinfected with neutral soap (Table 2). This may suggest that the effervescent tablets did not expose the pigment or create porosities in the materials, which might facilitate color degradation, as all other groups had the same behavior as group GI. In other words, the color change that occurred after the aging cycles is due to the structural alteration presented by the silicone when exposed to temperature variations and light. As a result of aging, the silicone presents color change caused by intrinsic and extrinsic factors.16, 21 The intrinsic factors involve the fading of the colorless silicone.16 Usually, this intrinsic fading occurs with the material aging due to several physiochemical conditions, such as thermal changes and humidity. Extrinsic factors such as absorption and adsorption of substances can also cause fading.36, 37, 38, 39 Other associated factors are responsible for color instability, such as accumulation of stains, dehydration, infiltration, superficial roughness, chemical degradation and usage, oxidation during the carbon double reactions producing peroxide compounds, and the continuous formation of pigments due to the material degradation.16

In the evaluation of each group disinfected with Efferdent after 60 days and submitted to different periods of artificial aging (Table 2), there was a noticed an increase of color change after 252 h of artificial aging for all groups, however, this increase was statistically significant for only groups GI and GIV. This fact can be justified by silicone degradation, once all groups presented the same behavior as group GI.5, 11

Several studies 3, 4, 6, 17, 18, 19, 20 have mentioned the use of artificial aging chambers in the evaluation of color stability of maxillofacial materials. The device exposes specimens to similar conditions of accelerated weather such as radiation, temperature, and humidity.3, 4, 17, 28

When values of E in the different aging periods were compared for each group (Table 2), it was observed that artificial aging promoted color change in all experimental groups. For some authors,16, 27 the adverse effect caused by the artificial aging in the tested materials is due to the action of three factors that take place during the artificial aging: solar irradiation (light energy), temperature, and water (humidity). The exposure to ultraviolet light is known to considerably change the color of elastomers. This color change may be caused by intrinsic chemical alterations of the silicone or by the loss of certain color pigments that are not UV-resistant.3, 4, 20, 34

Other authors27, 28, 29, 30 also found similar results and affirmed that opacifiers can protect facial silicones from color degradation, by blocking the ultraviolet light, and consequent degradation of nanoparticle pigments and also of the own elastomeric structure through the same action observed when they are added to sun shielding lotions.24, 25, 26, 35

In agreement with NBS, a color change is considered very low when E < 1. The situation is clinically acceptable if 1 < △E < 3; and it is considered clinically perceptible if △E > 3.36, 38 In the present study, the observed color change ranged from 0.435 to 2.044 (Table 2), therefore, it was not clinically perceptible.

These results are in agreement with Mancuso 3 who affirmed that the color change presented by colorless specimens of silicone and specimens pigmented with ceramic powder were not clinically perceptible even after 1000 h of artificial aging, demonstrating success in the color maintenance of facial prostheses with inorganic nanoparticle ceramic.

It is also possible to affirm, that the association between the ceramic pigment and the BaSO4 opacifier results in lower values of color change rather than when only the pigment is separately added to the silicone, because the opacifier promotes the reflection of the ultraviolet rays protecting the silicone and the pigments against color degradation.39

Nevertheless, all of the associations accomplished in this study can be clinically applied, as they are in agreement with previously described literature norms.36, 38, 40

5.

Conclusion

Within the limitations of the study and based on the obtained results, the following conclusions in relation to the facial silicone were drawn:

  • 1. Color changes occurred in all experimental periods, for all studied associations.

  • 2. The association between ceramic nanoparticles and BaSO4 opacifier was the most stable condition in relation to color maintenance, without considering disinfection and the aging period.

  • 3. All E values obtained in the present study, independent of the disinfectant and of the period of artificial aging, were considered clinically acceptable.

References

1. 

M. C. Goiato, A. A. Pesqueira, C. R. Silva, H. Gennari-Filho, and D. M. dos Santos, “Patient satisfaction with maxillofacial prosthesis: literature review,” J. Plast. Reconst. Aesthet. Surg., 62 175 –180 (2009). https://doi.org/10.1016/j.bjps.2008.06.084 Google Scholar

2. 

D. M. Hecker, “Maxillofacial rehabilitation of a large facial defect resulting from na arteriovenous malformation utilizing a two-piece prosthesis,” J. Prosthet. Dent., 89 109 –113 (2003). https://doi.org/10.1067/mpr.2003.23 Google Scholar

3. 

D. N. Mancuso, M. C. Goiato, and S. F. C. Dekon, “Evaluation visual of color stability after accelerated aging of pigmented and non-pigmented silicones to be used in facial prostheses,” Indian J. Dent. Res., 20 77 –80 (2009). https://doi.org/10.4103/0970-9290.49073 Google Scholar

4. 

D. M. Mancuso, M. C. Goiato, and D. M. Santos, “Color stability after accelerated aging of two silicones, pigmented or not, for use in facial prostheses,” Braz. Oral. Res., 23 144 –148 (2009). https://doi.org/10.1590/S1806-83242009000200009 Google Scholar

5. 

M. C. Goiato, A. A. Pesqueira, D. M. dos Santos, A. C. Zavanelli, and P. P. Ribeiro, “Color stability comparison of silicone facial prostheses following disinfection,” J. Prosthodont., 18 242 –244 (2009). https://doi.org/10.1111/j.1532-849X.2008.00411.x Google Scholar

6. 

S. Kiat-amnuay, D. A. Johnston, J. M. Powers, and R. F. Jacob, “Color stability of dry earth pigmented maxillofacial silicone A-2186 subjected to microwave energy exposure,” J. Prosthodont., 14 91 –96 (2005). https://doi.org/10.1111/j.1532-849X.2005.00017.x Google Scholar

7. 

J. F. Lontz, “State-of-the-art materials used for maxillofacial prosthetic reconstruction,” Dent. Clin. North Am., 34 307 –325 (1990). Google Scholar

8. 

N. H. Tran, M. Scarbecz, and J. J. Gary, “In vitro evaluation of color change in maxillofacial elastomer through the use of an ultraviolet light absorber and a hindered amine light stabilizer,” J. Prosthet. Dent., 91 483 –490 (2004). https://doi.org/10.1016/j.prosdent.2004.02.021 Google Scholar

9. 

J. J. Gary and C. T. Smith, “Pigments and their application in maxillofacial elastomers: a literature review,” J. Prosthet. Dent., 80 204 –208 (1998). https://doi.org/10.1016/S0022-3913(98)70111-8 Google Scholar

10. 

T. Ishigami, “A facial prosthesis made of porcelain fused to metal: a clinical report,” J. Prosthet. Dent., 77 564 –567 (1997). https://doi.org/10.1016/S0022-3913(97)70095-7 Google Scholar

11. 

A. M. Guiotti and M. C. Goiato, “Dimensional changing and maintenance of details evaluations of a silicone for use in maxillofacial prosthesis,” J. Dent. Res., 82 250 (2003). Google Scholar

12. 

J. C. Lemon, M. S. Chambers, M. L. Jacobsen, and J. M. Powers, “Color stability of facial prostheses,” J. Prosthet. Dent., 74 613 –618 (1995). https://doi.org/10.1016/S0022-3913(05)80314-2 Google Scholar

13. 

P. C. Montgomery and S. Kiat-amnuay, “Survey of currently used materials for fabrication of extraoral maxillofacial prostheses in North America, Europe, Asia and Australia,” J. Prosthodont., 19 482 –490 (2010). https://doi.org/10.1111/j.1532-849X.2009.00538.x Google Scholar

14. 

S. P. Haug, C. J. Andres, and B. K. Moore, “Color stability and colorant effect on maxillofacial elastomers. Part III: weathering effect on color,” J. Prosthet. Dent., 81 431 –438 (1999). https://doi.org/10.1016/S0022-3913(99)80010-9 Google Scholar

15. 

S. P. Haug, C. J. Andres, C. A. Munoz, and G. Bernal, “Effects of environmental factors on maxillofacial elastomers: Part IV—Optical properties,” J. Prosthet. Dent., 68 820 –823 (1992). https://doi.org/10.1016/0022-3913(92)90210-2 Google Scholar

16. 

D. M. dos Santos, M. C. Goiato, M. A. Sinhoreti, A. U. Fernandes, P. P. Ribeiro, and S. F. Dekon, “Color stability of polymers for facial prosthesis,” J. Craniofac. Surg., 21 54 –58 (2010). https://doi.org/10.1097/SCS.0b013e3181c3b58e Google Scholar

17. 

S. Kiat-Amnuay, T. Mekayarajjananonth, J. M. Powers, M. S. Chambers, and J. C. Lemon, “Interactions of pigments and opacifiers on color stability of MDX4-4210/type A maxillofacial elastomers subjected to artificial aging,” J. Prosthet. Dent., 95 249 –257 (2006). https://doi.org/10.1016/j.prosdent.2005.12.006 Google Scholar

18. 

S. Kiat-Amnuay, J. C. Lemon, and J. M. Powers, “Effect of opacifiers on color stability of pigmented maxillofacial silicone A-2186 subjected to artificial aging,” J. Prosthodont., 11 109 –116 (2002). https://doi.org/10.1053/jopr.2002.124357 Google Scholar

19. 

S. Kiat-amnuay, M. Beerbower, J. Powers, and R. D. Paravina, “Influence of pigments and opacifiers on color stability of silicone maxillofacial elastomer,” J. Dent., 37 45 –50 (2009). https://doi.org/10.1016/j.jdent.2009.05.004 Google Scholar

20. 

M. W. Beatty, G. K. Mahanna, K. Dick, and W. Jia, “Color changes in dry-pigmented maxillofacial elastomer resulting from ultraviolet light exposure,” J. Prosthet. Dent., 74 493 –498 (1995). https://doi.org/10.1016/S0022-3913(05)80351-8 Google Scholar

21. 

J. J. Gary, E. F. Huget, and L. D. Powell, “Accelerated color change in a maxillofacial elastomer with and without pigmentation,” J. Prosthet. Dent., 85 614 –620 (2001). https://doi.org/10.1067/mpr.2001.114683 Google Scholar

22. 

A. M. Burgos, I. Braghetto, A. Csendes, F. Maluenda, O. Korn, J. Yarmuch, and L. Gutierrez, “Gastric leak after laparoscopic-sleeve gastrectomy for obesity,” Obes. Surg., 19 1672 –1677 (2009). https://doi.org/10.1007/s11695-009-9884-9 Google Scholar

23. 

M. A. Hungaro Duarte, G. D. de Oliveira el Kadre, R. R. Vivan, J. M. Guerreiro Tanomaru, M. Tanomaru Filho, and I. G. de Moraes, “Radiopacity of portland cement associated with different radiopacifying agents,” J. Endod., 35 737 –740 (2009). https://doi.org/10.1016/j.joen.2009.02.006 Google Scholar

24. 

F. P. Gasparro, M. Mitchnick, and J. F. Nash, “A review of sunscreen safety an efficacy,” Photochem. Photobiol., 68 243 –256 (1998). https://doi.org/10.1111/j.1751-1097.1998.tb09677.x Google Scholar

25. 

H. S. Tichy and B. Catlow, “Use of titanium dioxide in sun care products,” Soap and Perfum Cosmetology, 65 37 (1992). Google Scholar

26. 

A. Janousek, “Regulatory aspects of sunscreens in Europe,” Sunscreen development, evaluation and regulatory aspects, 215 –225 Marcel Dekker, New York (1997). Google Scholar

27. 

M. C. Goiato, A. A. Pesqueira, D. M. dos Santos, R. M. Antenucci, and P. P. Ribeiro, “Evaluation of dimensional change and detail re-production in silicones for facial prostheses,” Acta. Odontol. Latinoam., 21 85 –88 (2008). Google Scholar

28. 

M. C. Goiato, A. A. Pesqueira, D. M. dos Santos, and S. F. Dekon, “Evaluation of hardness and surface roughness of two maxillofacial silicones following disinfection,” Braz. Oral. Res., 23 49 –53 (2009). Google Scholar

29. 

R. Yu, A. Koran III, and R. G. Craig, “Physical properties of a pigmented silicone maxillofacial materials as a function of accelerated aging,” J. Dent. Res., 59 1141 –1148 (1980). https://doi.org/10.1177/00220345800590070801 Google Scholar

30. 

Standard Method for Calculation of Color Differences from Instrumentally Measured Color Coordinates (ASTM D2244-85), Annual Book of ASTM Standards, pp. 213 –218 (1989) Google Scholar

31. 

A. C. Pavarina, A. Z. Pizzolitto, A. L. Machado, C. E. Vergani, and E. T. Giampaolo, “An infection control protocol: effectiveness of immersion solutions to reduce the microbial growth on dental prostheses,” J. Oral Rehabil., 30 532 –536 (2003). https://doi.org/10.1046/j.1365-2842.2003.01093.x Google Scholar

32. 

M. C. Goiato, D. M. Santos, H. Gennari Filho, A. C. Zavanelli, S. F. Dekon, and D. N. Mancuso, “Influence of investment, disinfection, and storage on the microhardness of ocular resins,” J. Prosthodont., 18 32 –35 (2009). https://doi.org/10.1111/j.1532-849X.2008.00372.x Google Scholar

33. 

ASTM 53 – American Society for Testing Materials Norma 53. Google Scholar

34. 

D. A. Tipton and J. W. Lewis, “Effects of a hindered amine light stabilizer and a UV light absorber used in maxillofacial elastomers on human gingival epithelial cells and fibroblasts,” J. Prosthet. Dent., 100 220 –231 (2008). https://doi.org/10.1016/S0022-3913(08)60182-1 Google Scholar

35. 

S. R. Pinel, M. D. D. Fairhust, R. Gillie, M. A. Mitchnick, and N. Kollias, “Microfine zinc oxide is a superior ingredient to microfine titanium dioxide,” Dermatol. Surg., 26 309 –314 (2000). https://doi.org/10.1046/j.1524-4725.2000.99237.x Google Scholar

36. 

R. G. Craig and J. M. Powers, “Repeatability of a specially designed intraoral colorimeter,” J. Prosthet. Dent., 69 616 –619 (1993). https://doi.org/10.1016/0022-3913(93)90292-V Google Scholar

37. 

W. H. Langwell, “Cleansing of artificial dentures,” Br. Dent. J., 99 337 (1995). Google Scholar

38. 

M. C. Goiato, B. C. Zuccolotti, A. Moreno, D. M. dos Santos, A. A. Pesqueira, and S. F. C. Dekon, “Colour change of soft denture liners after storage in coffee and coke,” Gerodontology, 28 140 –145 (2011). Google Scholar

39. 

D. M. dos Santos, M. C. Goiato, A. Moreno, A. A. Pesqueira, and M. F. Haddad, “Influence of pigments and opacifiers on color stability of an artificially aged facial silicone,” J. Prosthodont., 20 205 –208 (2011). Google Scholar

40. 

K. Stathi, P. A. Tarantili, and G. Polyzois, “The effect of accelerated aging on performance properties of addition type silicone biomaterials,” J. Mater. Sci.: Mater. Med., 21 1403 –1411 (2010). https://doi.org/10.1007/s10856-010-3991-y Google Scholar
©(2011) Society of Photo-Optical Instrumentation Engineers (SPIE)
Marcela Filie Haddad, Marcelo Coelho Goiato, Daniela Micheline dos Santos, Amalia Moreno, Aldieris Alves Pesqueira, and Nuno Filipe D'almeida "Color stability of maxillofacial silicone with nanoparticle pigment and opacifier submitted to disinfection and artificial aging," Journal of Biomedical Optics 16(9), 095004 (1 September 2011). https://doi.org/10.1117/1.3625401
Published: 1 September 2011
Lens.org Logo
CITATIONS
Cited by 35 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Silicon

Nanoparticles

Barium

Ceramics

Ultraviolet radiation

Tablets

Chlorine

RELATED CONTENT


Back to Top