Microfluidic optical devices are particularly suited for point-of-care analyte testing (POCT), and recent works1,2 have acknowledged their potential role in cancer diagnostics, public health, and environment protection. To achieve POCT, simplicity, low cost, and portability are essential. Among various optical assays, the chemiluminescence (CL) immunoassay is a simple but ideal solution for POCT, which is based on specific antibody–antigen interaction coupled with horseradish peroxidase (HRP)-luminol- luminescent reaction. A microfluidic CL detection system eliminates the need for external focusing optics and excitation sources,3 unlike a fluorescence-based system.4 In CL immunoassays, emitted 425- to 450-nm light is conventionally detected as either current or voltage using off-chip charge-coupled devices, photomultiplier tubes, or on-chip silicon photodiodes. While off-chip sensors are difficult to miniaturize into portable devices,3 on-chip silicon detectors involve complex microfabrication, which restrains their use in inexpensive microfluidic systems.5 On the contrary, organic photodetectors (OPDs) can be fabricated at low cost by simple spin-coating or spray-coating. The advantage of realizing thin device architectures () onto glass or plastic substrates makes OPDs well suited for integrated opto-microfluidics. Thus, the combination of OPDs with microfluidic CL immunoassays holds promise for truly disposable and compact devices. Biosensor sensitivity is also of particular concern in POCT systems. However, the OPDs recently reported for integrated microfluidic systems6 are still inferior to their silicon counterparts in optoelectronic performance. Bulk heterojunction OPDs based on blends of poly(3-hexylthiophene) (P3HT) and acid methyl ester () (Ref. 5) typically show specific detectivities () of Jones, while the typical of Si photodetectors are Jones.7 The development of OPDs of improved detectivity is essential to realize integrated microfluidic devices of high sensitivity. Nevertheless, the sensitivity can also be improved by the enhancement of the CL-based detection. Gold nanoparticles (AuNPs) can act as an enhancer of HRP-luminol- CL reactions8 besides their use in surface plasmon resonance or fluorescence spectroscopy. The enhancing effect of AuNPs could be applied to immunoassays while keeping the simplicity of the assay procedure. Despite this, AuNPs-based CL immunoassays have not yet been exploited in opto-microfluidic devices. This work reports on the development of an integrated opto-microfluidic device to perform enhanced CL immunoassays using AuNPs and high-detectivity OPD. The motivation here is to realize a miniaturized ultrasensitive approach for simple inexpensive POCT systems. The device integrates a glass slide with immobilized AuNPs to a poly(dimethylsiloxane) (PDMS) microchannel, fabricated by standard replica molding. The setup is completed by the attachment of a bulk heterojunction OPD based on blend, prepared by spin-coating on indium tin oxide (ITO)-coated glass slide. The integrated device was assembled via PDMS-glass bonding by use of simple oxygen plasma. Rapid microfluidic CL immunoassays were conducted in close proximity to immobilized AuNPs, and subsequent CL signals were detected as photocurrent by the OPD. The integrated AuNP-CL device is shown in Fig. 1. The PDMS microchannel consisted of nine parallel channel segments connecting one inlet and one outlet. Each channel segment measured 280 μm in width and 80 μm in depth. Separated nanoparticle lines covered the channel segments, which were previously assembled on the cover glass using 280-μm-wide trenches patterned on an auxiliary PDMS layer [Fig. 1(a)]. A reversible bonding method was used for the auxiliary PDMS and cover glass, thus permitting easy demounting [Fig. 1(b)] of the parts before permanent attachment of the cover glass to the PDMS channel layer [Figs. 1(c) and 1(d)]. The area () occupied by the AuNP lines on the glass matched to the active area of the integrated OPD. The procedure of AuNP immobilization included pretreatment of the AuNP surface and glass surface with dithiodipropionic acid and 3-aminopropyltriethoxysilane, respectively, followed by covalent binding via carboxylamine coupling reaction. Unreacted carboxyl groups on the AuNPs were further combined with biotinylated IgG antibody using NeutrAvidin. This method formed a large stable sensing surface within the microchannel, enabling efficient capture of antigen along multiple nanoparticle lines. Detection of captured antigen is carried out employing a competitive binding immunoassay principle. The target competes with added target-HRP conjugate for binding to antibody-modified AuNPs [Fig. 1(d)]. After washing out of unbounded material, the luminol- substrate interacts with HRP, which catalyzes the luminescent reaction. The intensity of generated blue light () is inversely proportional to the concentration of target analyte. For these assay conditions, it is expected that of an OPD, which is commonly expressed by , where is the effective area of the OPD, is the electrical bandwidth, is the responsivity, and is the noise current, is majorly limited by the shot noise from the dark current. Thus, can simply be calculated from the measured photocurrent () and dark current () following where is the incident light intensity and is the elementary charge constant ().The bulk heterojunction active layer was employed for the integrated OPD, which has incorporated spin-coated poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) as the hole transport layer and thermally evaporated LiF/Al as the top electrode. The detector was realized applying the diode architecture whose fabrication was previously described.9 No protective encapsulation was used here. PCDTBT is remarkably stable against oxidation due to its deep highest occupied molecular orbital level.10 Furthermore, the high short-circuit photocurrent and low dark current of the photodiode result in high [Eq. (1)]. At zero bias, the calculated was Jones for the detector under light-emitting diode illumination at 428 nm peak wavelength with light intensity. Nevertheless, an enhanced leads to a reduced noise equivalent power (NEP) level as demonstrated by and an improved NEP means an enhanced signal-to-background-current ratio (S/B).The S/B ratio was determined for a number of AuNP-CL assay tests. For the assays, estradiol (E2), an important endocrine disrupting compound detected in various water samples, was used as a model target and spiked in phosphate-buffered saline (PBS). E2 may be carcinogenic to human epithelial cells.11 The tests were conducted after the nonspecific binding sites within the microchannel were blocked with a commercial blocking buffer. OPD photocurrent was measured immediately after 5-min exposure to the luminol (pH 11.2) and solution using a 236 Keithley source-measure unit. The photocurrent obtained with E2-HRP was defined as background for S/B determination. The S/B ratio varied with the size of the AuNPs [Fig. 2(a)]. The decreased response for the AuNPs with diameter was due to absorption of CL emission by the Au surface plasmon resonance (SPR) phenomenon.12 The wavelength of SPR related absorption red shifts with the increase of AuNP size. Furthermore, the active surface area of the nanoparticles decreases with increasing particle size, and this may explain the reduced S/B for 100-nm AuNPs. No significant change in the OPD response was observed for a microchannel containing both 60- and 10-nm AuNPs at similar concentration. The concentration of E2-HRP conjugate was also found to be related to enhanced S/B. The variation of E2-HRP concentration from 1 to has led to an increase in detector response [Fig. 2(b)], which has resulted from an increased CL emission intensity. Figure 3 shows the calibration curve for E2 in PBS after device optimization. The curve was normalized by subtracting the measured photocurrent from that of the control sample containing only E2-HRP, and the resultant photocurrent variation () was fitted to a three-parameter logarithm equation at best. On the basis of the logarithmic fit, the detection limit was , which contrasts with obtained by CL immunoassays employing no AuNPs [Fig. 3(a)]. Furthermore, the lowest limit of previously reported OPD-based CL detection using photodetectors was .6 A run cycle of the AuNP-CL assay would take , including sample incubation and CL signal detection. The stability of the sensor response is relevant to single-use disposable POCT devices because of the possibility of long-term storage for these devices. The OPD-integrated AuNP-CL system was thus tested with E2 every three days and stored under ambient conditions between each test. After 15 days, the photocurrent response of one OPD decreased by only 25% of its initial value, presumably due to a small decrease in the charge mobilities of PCDTBT.10 The integrated device was further challenged with human blood serum and real water samples. Water was spiked with E2 after sample filtration through 0.22-μm pore size filters, while serum contained E2 as detected by a conventional enzyme-linked immunosorbent assay. The results of shown in Fig. 3(b) indicated slight interferences from serum, surface water and wastewater effluent samples in the assays, which did not compromise the feasibility of E2 detection. The enhancement of CL light intensity in proximity to AuNP lines, the high detectivity, and stability of the OPD and the possibility of detection in various complex matrices make the integrated device very promising for POCT. Ultrasensitivity was accompanied by rapid assay development and low-cost device fabrication. Moreover, the device concept can be broadly applied to other medically and environmentally relevant analytes. AcknowledgmentsResearch is supported by Oslofjorfondet (regional kvalifiseringsstøtte, proj. no: 229857) and Research Council of Norway via long term support to NorFab (197411/V30). The authors acknowledge Nanjing University of S&T, XMU, and CAS Institute of Hydrobiology, in China, for the assistance to the experiments. We also thank Professors Nils Høivik, Ulrik Hanke for useful discussions. ReferencesJ. OzhikandathilM. Packirisamy,
“Silica-on-silicon waveguide integrated polydimethylsiloxane lab-on-a-chip for quantum dot fluorescence bio-detection,”
J. Biomed. Opt., 17
(1), 017006
(2012). http://dx.doi.org/10.1117/1.JBO.17.1.017006 JBOPFO 1083-3668 Google Scholar
X. ZhaoT. Dong,
“Multifunctional sample preparation kit and on-chip quantitative nucleic acid sequence-based amplification tests for microbial detection,”
Anal. Chem., 84
(20), 8541
–8548
(2012). http://dx.doi.org/10.1021/ac3020609 ANCHAM 0003-2700 Google Scholar
J. R. Wojciechowskiet al.,
“Organic photodiodes for biosensors miniaturization,”
Anal. Chem., 81
(9), 3455
–3461
(2009). http://dx.doi.org/10.1021/ac8027323 ANCHAM 0003-2700 Google Scholar
N. M. M. PiresT. Dong,
“A cascade-like silicon filter for improved recovery of oocysts from environmental waters,”
Environ. Technol., 35
(6), 781
–790
(2014). http://dx.doi.org/10.1080/09593330.2013.851280 ENVTEV 0959-3330 Google Scholar
V. Charwatet al.,
“Standardization of microfluidic cell cultures using integrated organic photodiodes and electrode arrays,”
Lab Chip, 13
(5), 785
–797
(2013). http://dx.doi.org/10.1039/c2lc40965h LCAHAM 1473-0197 Google Scholar
R. Ishimatsuet al.,
“An organic thin film photodiode as a portable photodetector for the detection of alkylphenol polyethoxylates by a flow fluorescence-immunoassay on magnetic microbeads in a microchannel,”
Talanta, 117 139
–145
(2013). http://dx.doi.org/10.1016/j.talanta.2013.08.044 TLNTA2 0039-9140 Google Scholar
X. Gonget al.,
“High-detectivity polymer photodetectors with spectral response from 300 nm to 1450 nm,”
Science, 325
(5948), 1665
–1667
(2009). http://dx.doi.org/10.1126/science.1176706 SCIEAS 0036-8075 Google Scholar
M. Yanget al.,
“Gold nanoparticle-based enhanced chemiluminescence immunosensor for detection of Straphylococcal Enterotoxin B (SEB) in food,”
Int. J. Food Microbiol., 133
(3), 265
–271
(2009). http://dx.doi.org/10.1016/j.ijfoodmicro.2009.05.029 IJFMDD 0168-1605 Google Scholar
N. M. M. Pireset al.,
“Integrated optical microfluidic biosensor using a polycarbazole photodetector for point-of-care detection of hormonal compounds,”
J. Biomed. Opt., 18
(9), 097001
(2013). http://dx.doi.org/10.1117/1.JBO.18.9.097001 JBOPFO 1083-3668 Google Scholar
A. J. Heeger,
“Semiconducting polymers: the third generation,”
Chem. Soc. Rev., 39
(7), 2354
–2371
(2010). http://dx.doi.org/10.1039/b914956m CSRVBR 0306-0012 Google Scholar
S. Yuet al.,
“17-Beta-estradiol induces neoplastic transformation in prostatic epithelial cells,”
Cancer Lett., 304
(1), 8
–20
(2011). http://dx.doi.org/10.1016/j.canlet.2011.01.003 CALEDQ 0304-3835 Google Scholar
G. Luet al.,
“Influence of the nanoscale structure of gold thin films upon peroxidase-induced chemiluminescence,”
App. Phys. Lett., 88
(2), 023903
(2006). http://dx.doi.org/10.1063/1.2162701 APPLAB 0003-6951 Google Scholar
|