|
1.IntroductionBreast cancer is one of the highest occurrence rates of cancer among females and is still on the rise.1 By far, surgery remains the most viable option for breast cancer treatment. However, to increase the success rate of surgery, multiple cycles of neoadjuvant chemotherapy (3 to 6 months) are performed before the surgery to reduce the tumor size,2 and the tumor response from adjuvant chemotherapy could be confirmed by observing tumor volume change using mammography,3 ultrasound,4 and magnetic resonance imaging (MRI).5 However, it takes a few months to find if the adjuvant chemotherapy works on the tumor or not. Therefore, it is very important to develop a way to predict tumor response much earlier so that patients suffer less from the side effects of chemotherapy and thus enhance the quality of life. Compared with traditional imaging methods, diffuse optical technologies provide hemodynamics information such as blood volume, oxygenation, and flow from relatively deep tissue ().6 The system is low cost and safe with no radiation, and therefore, it is safe for daily monitoring tumor response to treatment. Recently, there have been various approaches to monitor tumor response during chemotherapy by utilizing diffuse optical imaging or tomography (DOI or DOT)7–9 and by combining two different optical techniques such as a combination of diffuse optical spectroscopy (DOS) with diffuse correlation spectroscopy (DCS).10 Diffuse optical spectroscopy/imaging (DOS/I) or DOT studies showed that there were significant differences of posttreatment oxy- (OHb), deoxy- (RHb), total (THb) hemoglobin, lipid, and water between responder and nonresponder compared with pretreatment.7,8 In the DOS with DCS study, chemotherapy caused significant changes in tumor versus normal blood flow contrast and concentrations of OHb, RHb, and lipid contrast compared with pretreatment.10 Others also have tried to detect or to monitor tumor response during chemotherapy by combination of diffuse optical tomography with other medical imaging modalities such as mammography,11 MRI,12 and ultrasound.13 There have also been interesting trials that applying a pressure on the breast,14 or vasoactive inhalational gases to the patient15 to detect tumors by causing a significant difference of hemodynamic contrast between normal (healthy) and tumor breast. In addition, there are reports of using the hemodynamic change during a breath-hold as a biomarker to predict tumor response to chemotherapy. Gunther et al.16 reported that THb and RHb concentration changes at two weeks after the first treatment are significantly different among pathologic complete response, pathologic partial response, and no response groups. They recently showed that kinetic parameters of deoxyhemoglobin change during a breath-hold show statistically significant differences between patients with pathologic complete response and without pathological complete response as determined 5 months after treatment initiation.17 However, it does not show longitudinal changes of hemodynamic parameters caused by a breath-hold during tumor growth and chemotherapy. Moreover, the breath-hold approach may not be suitable for patients, who have a lung disease, such as asthma.18 Connecting a ventilator to animals through tracheotomy will allow simulating a breath-hold in an animal study, but it prohibits a longitudinal study. Therefore, an inhalational gas intervention from hyperoxic to normoxic gas under anesthesia was applied to mimic the hemodynamic change caused by a breath-hold. In this study, a hyperoxic to normoxic gas intervention was applied to animals bearing breast tumor, and the hemodynamic changes during the mimicked breath-hold were compared with the change of tumor volume during tumor growth and chemotherapy. 2.Material and Methods2.1.Experimental SetupOur continuous-wave near-infrared spectroscopy (CWNIRS) system consists of two broadband light sources (tungsten halogen, HL-2000-HP, Ocean Optics) and two NIR spectrometers (600 to 1100 nm, USB 4000, Ocean Optics) as detectors. Two laptops were used to acquire and process the NIRS data. Each source and detector probe was fabricated to have bundled multimode optical fibers with 2-mm diameter and was placed on the top of breast tissue. The probe was carefully fixed on the breast with light pressure to minimize motion artifacts during the experiment. The nipple was centered between the source and detector fibers so that data can be taken from the same position on tumors as close as possible through experiments. Source and detector fibers were placed 5-mm apart. The inhalational gas intervention was performed using a gas mixer with an isoflurane vaporizer. We maintained 1.5% to 2% isoflurane to keep the anesthesia state of the animal and used a warm water pad to keep the animal body temperature and to prevent hypothermia under anesthesia state. 2.2.Animal ModelOne million of 13762 MAT B-III (CRL-1666, ATCC, Manassas, Virginia) rat breast cancer cells were inoculated onto a mammary fat pad of Fisher 344 female rats (180 to 200 g).19 Animals were divided into three groups (control, chemo, and early chemo group) with six animals per each group. To see the tumor volume dependence of tumor response to chemotherapy, chemo group (tumor volume ) received chemotherapy at day 7 post cell inoculation while early chemo group (tumor volume ) had chemotherapy at day 5 post cell inoculation. The detailed description of preparing animal breast tumor model can be found in our previous report. The size of the tumor was measured using a caliper daily, and its volume was calculated by ellipsoid volume formula. About 13,762 MAT B-III cancer cell line is known to highly respond to alkylating agents, such as cyclophosphamide. A single high dose of cyclophosphamide ( body weight) was administered via intraperitoneal (i.p.) injection to both chemo- and early chemo groups, whereas the control group received the same amount of saline. The procedures in this study were approved by the Institutional Animal Care and Use Committee of the Gwangju Institute of Science and Technology. 2.3.Experimental ProcedureInhalational oxygen gas modulation was performed automatically by a gas mixer system through a mask along with a continuous supply of isoflurane (1.5% to 2%). Baseline values were recorded for 3 min with 100% oxygen, and then the gas was switched to air for 10 min. Hemodynamic changes were monitored using CWNIRS for the entire 13 min of the protocol.5 The pulmonary oxygen saturation () values and heart rate (HR) were measured by a pulse oximeter (Mouse Ox, Starr Inc.) from a hind foot during the experiment. 2.4.Data AnalysisFor this study, we obtained reflectance intensities at five wavelengths (730, 750, 800, 830, and 850 nm) and applied the modified Beer–Lambert’s law to obtain concentration changes of oxy- (OHb), deoxy- (RHb), and total (THb) hemoglobin. The detailed description can be found in our previous report.19 Once the changes of OHb, RHb, and THb were acquired during a respiratory challenge, was measured starting from the time it starts falling for another minute when 100% oxygen was switched to air [Fig. 1(a)]. 2.5.Statistical AnalysisA two-tailed, paired sample -test was applied to examine whether and tumor volume decrease after reaching their maximum are significant from the maximum values. For instances, at day 2 postchemotherapy (day 11 in chemo group and day 9 in early chemo group) and the value at day 1 postchemotherapy were compared (day 10 in chemo group and day 8 in early chemo group). Tumor volume at day 3 postchemotherapy was also compared with the value at day 2 postchemotherapy. A -value of was considered as a statistically significant difference. 3.ResultsA representative change of OHb and RHb concentration from 100% oxygen to 21% oxygen inhalation is shown in Fig. 1. As the inhalation gas was switched to normoxic gas, value decreased from 97% to 91%, and heart rate increased from 320/min to 345/min at the end of air inhalation. The low value of air inhalation is due to the suppression of pulmonary function from isoflurane anesthesia effect.20 Therefore, 100% oxygen inhalation under anesthesia can represent the oxygen supply during air breathing in a patient, and 21% oxygen gas breathing can mimic the low oxygen delivery during a breath-hold in a patient. Figures 1(b)–1(d) show the absolute values of averaged dropped OHb concentration with tumor volume change from both the contralateral breast, , and tumor breast, , in control [Fig. 1(b)], chemo [Fig. 1(c)], and early chemo group [Fig. 1(d)]. As shown in Figs. 1(b)–1(d), the changes of in the contralateral breast for all groups kept almost same value during the whole experiment. In contrast, the changes of show different trends compared with the changes of as the tumor grows and during chemotherapy. As can be seen in Fig. 1(b), in tumor breast increased as tumors grow until the end of the experiment. The measurement was ceased at day 13 due to large tumor volume (), which had to be sacrificed. For the chemo group, cyclophosphamide was administrated at 7 days after cell inoculation when tumor size grew to in diameter. corresponded well with the change of tumor volume during tumor growth and chemotherapy. However, it should be emphasized that started to decrease 1 day earlier than tumor volume changes after chemotherapy (-value = 0.06 between day 1 and day 2 posttreatment). Figure 1(d) shows the result of early chemo group. As tumor response to chemotherapy can be different depending on tumor size at the time of chemotherapy start, chemotherapy was performed 2 days earlier than chemo group ( to of tumor diameter). The tumor showed a very rapid decrease in the volume after chemotherapy compared with chemo group, whereas the trend of change was similar, but much smaller in magnitude compared with chemo group due to small tumor size at the time of cyclophosphamide administration. at day 2 postchemotherapy (day 9) became significantly small compared with the value at day 1 postchemotherapy (day 8). This result again showed that started to decrease 1 day earlier than tumor volume changes after chemotherapy. Figure 2 shows the averaged changes of , , and along with the tumor growth and regression from chemo, early chemo, and control group. In chemo- and early chemo groups, both [Fig. 2(a)] and [Fig. 2(b)] continued to increase during tumor growth, and then returned to baseline after chemotherapy. The were obtained by subtracting the from Compared with and , values were relatively constant in all groups. It means the amount of and are similar to each other during inhalational oxygen gas intervention. 4.DiscussionIn this study, we monitored the change of OHb concentration during the inhalation of hyperoxic (100% oxygen) to normoxic (21% oxygen + 79% nitrogen) gas during tumor growth and after chemotherapy. The purpose of this protocol is to mimic a breath-hold, which has been applied in a clinical study to differentiate tumor from the nontumor. The voluntary breath-hold test has an advantage that it does not need an additional device or a machine to modulate inhalational oxygen concentration, but it may not be comfortable to patients, who are elderly or have respiratory diseases, such as asthma.18 Moreover, the breath-hold time may vary depending on subjects, and thus it can be hard to analyze the data and to conclude the results from many patients. The goal of this study was to apply a breath-hold to monitor tumor response to chemotherapy in an anesthetized animal model. Even though connecting a ventilator to animals through tracheotomy will allow us to simulate a breath-hold, it prohibits a longitudinal study such as collecting hemodynamic signals throughout tumor growth and chemotherapy. Therefore, respiratory challenges were designed to mimic the condition of breath-hold in human subjects as follows. In a normal condition, is close to 100% with an air inhalation, but it is much lower in an anesthetized animal (91% to 92%) during air inhalation due to a suppression of pulmonary function as can be seen in Fig. 1(a). Therefore, we applied 100% oxygen gas to make to around 98%, which mimics air breathing in a normal condition. Strohl et al.21 in 1984 showed that is falling with a rate of 0.16%/s during a breath-hold when initial was 97%. Thus, 30 s of breath-hold in Flexman et al.’s report will cause close to 92%, and therefore, drop in anesthetized animals from 100% oxygen gas to air inhalation can simulate a breath-hold condition in a patient. It became a question that what will be the minimum oxygen percentage in inhalational gas to make a safe condition in clinical trials. To answer this question, the literature was surveyed to find the degree of oxygen saturation and oxygen percentage in the air that does not cause health problems in humans. According to the Wilderness Medicine book,22 oxygen saturation is above 95% at an altitude below 2000 m, which has 16.3% as an effective oxygen. In the case of Denver (Colorado), which located at a high altitude (), the effective oxygen is about 17.3%, and Aspen at Colorado has of effective oxygen and 92% oxygen saturation due to a higher altitude () than Denver. Even with this low oxygen level, however, these cities are attractive places where many citizens and tourists can stay without having health problems. Therefore, a respiratory challenge from air to hypoxic (16% oxygen + 84% nitrogen) gas instead of a breath-hold may be suitable in clinical tests to provide a contrast between tumor and nontumor without having problems that a breath-hold test may cause. The reason why a respiratory challenge from 100% oxygen to air was not considered for clinical setting instead of air to hypoxic gas is that during air inspiration is already close to 100%, and thus 100% oxygen breathing does not improve much. Therefore, a switch from 100% oxygen to air-breathing cannot cause a significant change in tissue oxygenation. Compared with this, switching inhalational gas from air to 16% oxygen will make changing from 98% to , which may cause a sufficient change in tumor oxygenation while normal tissue maintains its oxygenation by autoregulatory vascular reactivity. The Hielscher group applied a voluntary breath-hold as a physiological intervention to cause a hemodynamic change in breast tissue, which was monitored by diffuse optical tomography imaging system. They found that the percentage change of RHb ( ) during a breath-hold shows a higher contrast than the percentage change of OHb () in tumor region.18 However, our results show that both and correlated well with tumor growth from all groups (Fig. 2). Recently, they reported the results of utilizing breath-hold-induced hemodynamic parameters to predict the response to neoadjuvant chemotherapy.17 They found that the kinetic parameters rather than the magnitude of Δ[RHb]% can better predict patients with the pathologic complete response and also nonresponders to neoadjuvant chemotherapy. In our study, kinetic parameters were not analyzed due to the lack of 100% inhalation after air breathing, but itself showed potential as a biomarker to predict the response to chemotherapy by showing a response one day earlier than tumor volume change (Fig. 1). However, there are some limitations and issues to be addressed in this study. First, this study does not include the data from “nonresponding” group, and therefore it is hard to know if the trend of is different in tumors not responding to cyclophosphamide. Even though this study does not have data from the nonresponding group, previous clinical studies showed that there exists a significant difference between pathologically complete response versus incomplete response group in terms of percentage change of total hemoglobin during the first cycle of adjuvant chemotherapy.23 Another study also showed that the trends of both blood flow and total hemoglobin concentration are different depending on the level of response to chemotherapy.10 Therefore, it is reasonable to believe that during a respiratory challenge will also be different between responding and nonresponding tumor, but it should be confirmed by further study. Second, the duration time and the concentration of oxygen during a hypoxic gas inhalation need to be optimized to ensure the safety of patients when the inhalational protocol is applied to clinic test. According to our results, HR and levels fell quickly and then maintained their level during 10 min of air inhalation (hypoxic gas in the clinical test). As the cardiopulmonary function and metabolism between a rat and human are different, clinical trials are required to optimize the inhalation protocol to ensure the safety and also the maximum contrast between tumor and normal breast. Third, a hemoglobin concentration change during the respiratory challenge was acquired with the assumption that scattering property of tumor does not change during the respiratory challenge. However, there is a high chance that scattering property will change as the respiratory challenge causes both blood volume and oxygenation changes, which will affect the scattering property. How much of this scattering property change will affect the results of this study can be answered by employing a quantitative NIRS system such as time-domain and frequency-domain systems. Despite these limitations, our results showed a high potential tumor response that could be monitored by observing tumor hemodynamics during a respiratory challenge, and it may show an earlier response than the tumor volume change. 5.ConclusionsA respiratory challenge of switching from 100% oxygen to 21% oxygen gas was applied to anesthetized animals during tumor growth and chemotherapy to mimic the breath-hold in a clinical test. The results showed that in tumor breast during the first minute of respiratory challenge correlated well with tumor growth, whereas the contralateral nontumor breast showed a similar level of OHb drops regardless of tumor size. It has also been found that the during the respiratory challenge responded one day earlier than the tumor volume changes after chemotherapy. These results support that hemodynamic changes during a breath-hold or an inhalational oxygen gas intervention can be a biomarker to monitor an earlier response to chemotherapy than monitoring tumor volume change. DisclosuresWe declare that there are no relevant financial interests and no other potential conflicts of interest in this article. AcknowledgmentsThis work was partially supported by the National Research Foundation of Korea (NRF) Grants (2013R1A1A2013625 and 2015R1D1A1A02062382), the “Biomedical Integrated Technology Research” project through a grant provided by GIST in 2018, and the GIST Research Institute (GRI) in 2018. ReferencesR. L. Siegel et al.,
“Cancer statics, 2017,”
CA Cancer J. Clin., 67
(1), 7
–30
(2017). http://dx.doi.org/10.3322/caac.21387 CAMCAM 0007-9235 Google Scholar
M. Kaufmann et al.,
“Recommendations from an international consensus conference on the current status and future of neoadjuvant systemic therapy in primary breast cancer,”
Ann. Surg. Oncol., 19
(5), 1508
–1516
(2012). http://dx.doi.org/10.1245/s10434-011-2108-2 Google Scholar
J. E. Martin et al.,
“Breast cancer missed by mammography,”
Am. J. Roentgenol., 132
(5), 737
–739
(1979). http://dx.doi.org/10.2214/ajr.132.5.737 AJROAM 0092-5381 Google Scholar
H. M. Zonderland et al.,
“Diagnosis of breast cancer: contribution of US as an adjunct to mammography,”
Radiology, 213
(2), 413
–422
(1999). http://dx.doi.org/10.1148/radiology.213.2.r99nv05413 RADLAX 0033-8419 Google Scholar
C. E. Loo et al.,
“Magnetic resonance imaging response monitoring of breast cancer during neoadjuvant chemotherapy: relevance of breast cancer subtype,”
J. Clin. Oncol., 29
(6), 660
–666
(2011). http://dx.doi.org/10.1200/JCO.2010.31.1258 JCONDN 0732-183X Google Scholar
B. J. Tromberg et al.,
“Non-invasive in vivo characterization of breast tumors using photon migration spectroscopy,”
Neoplasia, 2 26
–40
(2000). http://dx.doi.org/10.1038/sj.neo.7900082 Google Scholar
A. Cerussi et al.,
“Predicting response to breast cancer neoadjuvant chemotherapy using diffuse optical spectroscopy,”
Proc. Natl. Acad. Sci. U.S.A., 104 4014
–4019
(2007). http://dx.doi.org/10.1073/pnas.0611058104 PNASA6 0027-8424 Google Scholar
S. Jiang et al.,
“Predicting breast tumor response to neoadjuvant chemotherapy with diffuse optical spectroscopic tomography prior to treatment,”
Clin. Cancer Res., 20 6006
–6015
(2014). http://dx.doi.org/10.1158/1078-0432.CCR-14-1415 Google Scholar
R. Choe and T. Durduran,
“Diffuse optical monitoring of the neoadjuvant breast cancer therapy,”
IEEE J. Sel. Top. Quantum Electron., 18
(4), 1367
–1386
(2012). http://dx.doi.org/10.1109/JSTQE.2011.2177963 IJSQEN 1077-260X Google Scholar
C. Zhou et al.,
“Diffuse optical monitoring of blood flow and oxygenation in human breast cancer during early stages of neoadjuvant chemotherapy,”
J. Biomed. Opt., 12
(5), 051903
(2007). http://dx.doi.org/10.1117/1.2798595 JBOPFO 1083-3668 Google Scholar
B. B. Zimmermann et al.,
“Multimodal breast cancer imaging using coregistered dynamic diffuse optical tomography and digital breast tomosynthesis,”
J. Biomed. Opt., 22
(4), 046008
(2017). http://dx.doi.org/10.1117/1.JBO.22.4.046008 JBOPFO 1083-3668 Google Scholar
J. Feng et al.,
“Breast cancer detection using Ktrans MRI imaging to guide near infrared spectroscopy tomography,”
Proc. SPIE, 10059 100590O
(2017). http://dx.doi.org/10.1117/12.2250649 PSISDG 0277-786X Google Scholar
C. Xu et al.,
“Ultrasound-guided diffuse optical tomography for predicting and monitoring neoadjuvant chemotherapy of breast cancers: recent progress,”
Ultrason. Imaging, 38 5
–18
(2016). http://dx.doi.org/10.1177/0161734615580280 ULIMD4 0161-7346 Google Scholar
S. A. Carp et al.,
“Compression-induced changes in the physiological state of the breast as observed through frequency domain photon migration measurements,”
J. Biomed. Opt., 11
(6), 064016
(2006). http://dx.doi.org/10.1117/1.2397572 JBOPFO 1083-3668 Google Scholar
C. M. Carpenter et al.,
“Inspired gas-induced vascular change in tumors with magnetic-resonance-guided near-infrared imaging: human breast pilot study,”
J. Biomed. Opt., 15
(3), 036026
(2010). http://dx.doi.org/10.1117/1.3430729 JBOPFO 1083-3668 Google Scholar
J. Gunther et al.,
“Combined dynamic and static optical tomography for prediction of treatment outcome in breast cancer patients,”
Proc. SPIE, 9538 953811
(2015). http://dx.doi.org/10.1117/12.2183996 PSISDG 0277-786X Google Scholar
J. Gunther et al.,
“Dynamic diffuse optical tomography for monitoring neoadjuvant chemotherapy in patients with breast cancer,”
Radiology, 287
(2), 161041
(2018). http://dx.doi.org/10.1148/radiol.2018161041 RADLAX 0033-8419 Google Scholar
M. L. Flexman et al.,
“Optical biomarkers for breast cancer derived from dynamic diffuse optical tomography,”
J. Biomed. Opt., 18
(9), 096012
(2013). http://dx.doi.org/10.1117/1.JBO.18.9.096012 JBOPFO 1083-3668 Google Scholar
S. Lee et al.,
“Change of tumor vascular reactivity during tumor growth and postchemotherapy observed by near-infrared spectroscopy,”
J. Biomed. Opt., 22
(12), 121603
(2017). http://dx.doi.org/10.1117/1.JBO.22.12.121603 JBOPFO 1083-3668 Google Scholar
H. E. Fourcade et al.,
“The ventilator effects of Forane, a new inhaled anesthetic,”
Anesthesiology, 35 26
–31
(1971). http://dx.doi.org/10.1097/00000542-197107000-00008 ANESAV 0003-3022 Google Scholar
K. P. Strohl et al.,
“Oxygen saturation during breath-holding and during apneas in sleep,”
Chest, 85
(2), 181
–186
(1984). http://dx.doi.org/10.1378/chest.85.2.181 CHETBF 0012-3692 Google Scholar
P. H. Hackett and R. C. Roach, Wilderness Medicine, 3rd ed.Mosby, St. Louis, Missouri
(1995). Google Scholar
D. Roblyer et al.,
“Optical imaging of breast cancer oxyhemoglobin flare correlates with neoadjuvant chemotherapy response one day after starting treatment,”
Proc. Natl. Acad. Sci. U.S.A., 108
(35), 14626
–14631
(2011). http://dx.doi.org/10.1073/pnas.1013103108 PNASA6 0027-8424 Google Scholar
BiographySonghyun Lee is a researcher in the Biophotonics Laboratory, Department of Biomedical Science and Engineering, Gwangju Institute of Science and Technology, Gwangju, Korea. He received his PhD from Gwangju Institute of Science and Technology, Gwangju, Korea, in 2018. Jae Gwan Kim is a professor in the Department of BMSE, GIST, Gwangju, Republic of Korea. Before joining GIST, he was a postdoctoral scholar at the Beckman Laser Institute and Medical Clinic, University of California, Irvine. He received his PhD from Joint Program of Biomedical Engineering between the University of Texas (UT), Arlington and the UT Southwestern Medical Center, Dallas, in 2005. |