12 September 2017 Stereovision-based integrated system for point cloud reconstruction and simulated brain shift validation
Xiaochen Yang, Logan W. Clements, Ma Luo, Saramati Narasimhan, Reid C. Thompson, Benoit M. Dawant, Michael I. Miga
Author Affiliations +
Abstract
Intraoperative soft tissue deformation, referred to as brain shift, compromises the application of current image-guided surgery navigation systems in neurosurgery. A computational model driven by sparse data has been proposed as a cost-effective method to compensate for cortical surface and volumetric displacements. We present a mock environment developed to acquire stereoimages from a tracked operating microscope and to reconstruct three-dimensional point clouds from these images. A reconstruction error of 1 mm is estimated by using a phantom with a known geometry and independently measured deformation extent. The microscope is tracked via an attached tracking rigid body that facilitates the recording of the position of the microscope via a commercial optical tracking system as it moves during the procedure. Point clouds, reconstructed under different microscope positions, are registered into the same space to compute the feature displacements. Using our mock craniotomy device, realistic cortical deformations are generated. When comparing our tracked microscope stereo-pair measure of mock vessel displacements to that of the measurement determined by the independent optically tracked stylus marking, the displacement error was ∼2  mm on average. These results demonstrate the practicality of using tracked stereoscopic microscope as an alternative to laser range scanners to collect sufficient intraoperative information for brain shift correction.
© 2017 Society of Photo-Optical Instrumentation Engineers (SPIE) 2329-4302/2017/$25.00 © 2017 SPIE
Xiaochen Yang, Logan W. Clements, Ma Luo, Saramati Narasimhan, Reid C. Thompson, Benoit M. Dawant, and Michael I. Miga "Stereovision-based integrated system for point cloud reconstruction and simulated brain shift validation," Journal of Medical Imaging 4(3), 035002 (12 September 2017). https://doi.org/10.1117/1.JMI.4.3.035002
Received: 3 May 2017; Accepted: 14 August 2017; Published: 12 September 2017
Lens.org Logo
CITATIONS
Cited by 6 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Microscopes

Clouds

Calibration

Brain

Optical tracking

System integration

Cameras

Back to Top