6 March 2018 Initial evaluation of image performance of a 3-D x-ray system: phantom-based comparison of 3-D tomography with conventional computed tomography
Robyn Melanie Benz, Meritxell Alzamora Garcia, Felix Amsler, Johannes Voigt, Andreas Fieselmann, Anna Lucja Falkowski, Bram Stieltjes, Anna Hirschmann
Author Affiliations +
Abstract
Phantom-based initial performance assessment of a prototype three-dimensional (3-D) x-ray system and comparison of 3-D tomography with computed tomography (CT) were proposed. A 3-D image quality phantom was scanned with a prototype version of 3-D cone-beam CT imaging implemented on a twin robotic x-ray system using three trajectories (163 deg = table, 188 deg = upright, and 200 deg = side), six tube voltages (60, 70, 81, 90, 100, and 121 kV), and four detector doses (0.348, 0.696, 1.740, and 3.480  μGy  /  projection). CT was obtained with a clinical protocol. Spatial resolution (line pairs/cm) and soft-tissue-contrast resolution were assessed by two independent readers. Radiation dose was assessed. Descriptive and analysis of variance (ANOVA) (P  <  0.05) were performed. With 3-D tomography, a maximum of 16 lp/cm was visible and best soft-tissue-contrast resolution was 2 mm at 30 Hounsfield units (HU) for 160 projections. With CT, 10 lp/cm was visible and soft-tissue-contrast resolution was 4 mm at 20 HU. The upright trajectory yielded significantly better spatial resolution and soft tissue contrast, and the side trajectory yielded significantly higher soft tissue contrast than the table trajectory (P  <  0.05). Radiation dose was higher in 3-D tomography (45 to 704 mGycm) than CT (44 mGycm). Three-dimensional tomography renders overall equal or higher spatial resolution and comparable soft tissue contrast to CT for medium- and high-dose protocols in the side and upright trajectories, but with higher radiation doses.
© 2018 Society of Photo-Optical Instrumentation Engineers (SPIE) 2329-4302/2018/$25.00 © 2018 SPIE
Robyn Melanie Benz, Meritxell Alzamora Garcia, Felix Amsler, Johannes Voigt, Andreas Fieselmann, Anna Lucja Falkowski, Bram Stieltjes, and Anna Hirschmann "Initial evaluation of image performance of a 3-D x-ray system: phantom-based comparison of 3-D tomography with conventional computed tomography," Journal of Medical Imaging 5(1), 015502 (6 March 2018). https://doi.org/10.1117/1.JMI.5.1.015502
Received: 12 September 2017; Accepted: 2 February 2018; Published: 6 March 2018
Lens.org Logo
CITATIONS
Cited by 11 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
3D image processing

Tomography

X-ray computed tomography

X-rays

Tissues

Spatial resolution

X-ray imaging

RELATED CONTENT

Internal channel structures in trabecular bone
Proceedings of SPIE (October 26 2004)
Quality assessment of clinical computed tomography
Proceedings of SPIE (September 15 2008)
X-ray micro-CT Scanner For Biomedical Applications
Proceedings of SPIE (September 19 1985)
3D threat image projection
Proceedings of SPIE (March 10 2008)

Back to Top