10 March 2014 Optometric measurements predict performance but not comfort on a virtual object placement task with a stereoscopic three-dimensional display
John P. McIntire, Steve T. Wright, Lawrence K. Harrington, Paul R. Havig II, Scott N. Watamaniuk, Eric L. Heft
Author Affiliations +
Abstract
Twelve participants were tested on a simple virtual object precision placement task while viewing a stereoscopic three-dimensional (S3-D) display. Inclusion criteria included uncorrected or best corrected vision of 20/20 or better in each eye and stereopsis of at least 40 arc sec using the Titmus stereotest. Additionally, binocular function was assessed, including measurements of distant and near phoria (horizontal and vertical) and distant and near horizontal fusion ranges using standard optometric clinical techniques. Before each of six 30 min experimental sessions, measurements of phoria and fusion ranges were repeated using a Keystone View Telebinocular and an S3-D display, respectively. All participants completed experimental sessions in which the task required the precision placement of a virtual object in depth at the same location as a target object. Subjective discomfort was assessed using the simulator sickness questionnaire. Individual placement accuracy in S3-D trials was significantly correlated with several of the binocular screening outcomes: viewers with larger convergent fusion ranges (measured at near distance), larger total fusion ranges (convergent plus divergent ranges, measured at near distance), and/or lower (better) stereoscopic acuity thresholds were more accurate on the placement task. No screening measures were predictive of subjective discomfort, perhaps due to the low levels of discomfort induced.
© 2014 Society of Photo-Optical Instrumentation Engineers (SPIE) 0091-3286/2014/$25.00 © 2014 SPIE
John P. McIntire, Steve T. Wright, Lawrence K. Harrington, Paul R. Havig II, Scott N. Watamaniuk, and Eric L. Heft "Optometric measurements predict performance but not comfort on a virtual object placement task with a stereoscopic three-dimensional display," Optical Engineering 53(6), 061711 (10 March 2014). https://doi.org/10.1117/1.OE.53.6.061711
Published: 10 March 2014
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Distance measurement

3D displays

Eye

Optical engineering

Cameras

Prisms

Visualization

RELATED CONTENT


Back to Top