Paper
31 December 1980 Alignment Techniques Required By Precise Measurement Of Effective Focal Length
Timothy D. Wise
Author Affiliations +
Abstract
The ability to measure the absolute effective focal length (EFL) of high resolution tele-scopic systems is limited by errors in the alignment of the test equipment used for the measurement. The types of errors are usually dependent upon the specific test equipment used and the way in which it is set up. While these time independent (D.C.) misalignments are of serious concern, other environmentally-dependent misalignments can be equally dis-turbing; the periods of these dynamic misalignments range from 30 minutes or more to a millisecond. In an effort to measure EFL to better than one part in 104, an extensive study of all known sources of misalignment has been carried out in addition to simply evalu-ating the statistical error associated with repeated EFL determinations. This investiga-tion utilized strain gauges, precision knife edges, assorted lasers, mechanical fixtures, accelerometers, seismometers, position sensing detectors, interferometers, and a PDP 11/70 computer. Reported here are The real constraints to be observed in setting up a laser interferometer How support fixtures should be manufactured The effects of test-table bending in thermally unstable environments The ways to minimize beam steering effects over long optical paths The inadequacies of "vibration-isolated" tables How precisely one can expect to measure EFL absolutely
© (1980) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Timothy D. Wise "Alignment Techniques Required By Precise Measurement Of Effective Focal Length", Proc. SPIE 0251, Optical Alignment I, (31 December 1980); https://doi.org/10.1117/12.959448
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Interferometers

Telescopes

Optical alignment

Mirrors

Optical fabrication

Sensors

Motion measurement

RELATED CONTENT

The GMT telescope metrology system design
Proceedings of SPIE (August 29 2022)
A 3D metrology system for the GMT
Proceedings of SPIE (August 08 2016)
Lessons learned from the optics and focal plane alignment of...
Proceedings of SPIE (September 12 2005)
An alignment strategy for the optics of LINC-NIRVANA
Proceedings of SPIE (September 24 2012)
Development of Cassegrain type 0.9-m collimator
Proceedings of SPIE (August 18 2005)
Optical Characterization Of The Lockheed Sensor Test Facility
Proceedings of SPIE (September 22 1983)

Back to Top