Abstract
Temporal parameters of synchrotron pulse radiation at damping ring (DP) installation of VEPP-5 type were measured with the help of PS-1/S1 picosecond streak camera having 1.5 ps time resolution. These measurements were proceeded within 400-900 nm spectral range. It has been shown that our streak camera may record either a train of electron bunches with ns-duration or internal structure inside a single bunch. We were able to record the distance ~ 1.5 ns between separate bunches as well as their amplitude, which depends on particle numbers inside a bunch. Depending on linear accelerator mode of operation it was possible to define a single bunch duration, which was deviated within the range of 20-100 ps. The temporal structure of a single bunch was measured with 1.5 ps time accuracy. As a result, the VEPP-5 damping ring parameters were optimized, and particles injection conditions were improved. In addition, we have measured the temporal parameters of Vavilov-Cherenkov radiation (VCR) emitted by electron beam of linear accelerator. Our results provided important information on electron bunches formation and their quality inside linear accelerator before electrons injection inside a damping ring. Another series of experiments were done at VEPP-4M electron-positron collider. The dependence of beam length of the beam current measured with streak-camera allowed us to compute the wide-band impedance of the accelerator. The same data were obtained at Siberia-2 synchrotron radiation source (NRC “Kurchatov Institute”, Moscow).
© (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
N. S. Vorobiev, P. B. Gornostaev, V. L. Dorokhov, V. N. Korchuganov, V. I. Lozovoi, O. I. Meshkov, Xiaochao Ma, D. A. Nikiforov, A. V. Smirnov, E. V. Shashkov, M. Ya. Schelev, A. I. Stirin, A. G. Valentinov, and A. K. Vereshchagin "Picosecond streak-cameras for bunch diagnostics in accelerators", Proc. SPIE 10328, Selected Papers from the 31st International Congress on High-Speed Imaging and Photonics, 103280N (20 February 2017); https://doi.org/10.1117/12.2268720
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Particles

Streak cameras

Cameras

Quartz

Temporal resolution

Mirrors

Electron beams

RELATED CONTENT

Streak Photography of Impact Spalled Thin ( 125 micron )...
Proceedings of SPIE (January 09 1984)
Tri-OSST
Proceedings of SPIE (June 22 1999)
C 850X picosecond high-resolution streak camera
Proceedings of SPIE (April 01 1991)
Direct observation of shaped-charge jets
Proceedings of SPIE (January 01 1993)

Back to Top